Part Number Hot Search : 
BU210 AW08G N4001 87C196 MMBT390 EL2227CS PD030 02204
Product Description
Full Text Search
 

To Download PM8315 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
PM8315
TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MULTIPLEXER
DATASHEET
PROPRIETARY AND CONFIDENTIAL ISSUE 7: MAY 2001
PMC-Sierra, Inc.
105 - 8555 Baxter Place Burnaby, BC Canada V5A 4V7 604 .415.6000
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
CONTENTS 1 2 3 4 5 FEATURES .............................................................................................. 1 APPLICATIONS ..................................................................................... 15 REFERENCES....................................................................................... 16 APPLICATION EXAMPLES ................................................................... 20 BLOCK DIAGRAM ................................................................................. 21 5.1 5.2 5.3 5.4 6 7 8 9 TOP LEVEL BLOCK DIAGRAM .................................................. 21 M13 MULTIPLEXER MODE BLOCK DIAGRAM ......................... 23 VT/TU MAPPER ONLY MODE BLOCK DIAGRAM..................... 23 DS3 FRAMER ONLY BLOCK DIAGRAM .................................... 24
DESCRIPTION ...................................................................................... 26 PIN DIAGRAM ....................................................................................... 31 PIN DESCRIPTION................................................................................ 32 FUNCTIONAL DESCRIPTION............................................................... 70 9.1 9.2 1.3 1.4 1.5 1.6 1.7 1.8 T1 FRAMER (T1-FRMR) ............................................................. 70 E1 FRAMER (E1-FRMR)............................................................. 70 PERFORMANCE MONITOR COUNTERS (T1/E1-PMON)......... 77 BIT ORIENTED CODE DETECTOR (RBOC).............................. 78 HDLC RECEIVER (RDLC) .......................................................... 78 T1 ALARM INTEGRATOR (ALMI)............................................... 79 ELASTIC STORE (ELST)............................................................ 80 SIGNALING ELASTIC STORES (RX-SIG-ELST AND TX_SIG-ELST) ............................................................................ 80
PROPRIETARY AND CONFIDENTIAL
i
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
1.9 1.10 1.11 1.12 1.13 1.14 1.15 1.16 1.17 1.18 1.19 1.20 1.21 1.22 1.23 1.24 1.25 1.26 1.27 1.28 1.29
SIGNALING EXTRACTOR (SIGX).............................................. 81 RECEIVE PER-CHANNEL SERIAL CONTROLLER (RPSC)...... 82 BASIC TRANSMITTER (XBAS) .................................................. 82 E1 TRANSMITTER (E1-TRAN)................................................... 83 TRANSMIT PER-CHANNEL SERIAL CONTROLLER (TPSC).... 83 SIGNALING ALIGNER (SIGA) .................................................... 83 BIT ORIENTED CODE GENERATOR (XBOC) ........................... 84 HDLC TRANSMITTERS (TDPR)................................................. 84 T1 AUTOMATIC PERFORMANCE REPORT GENERATION (APRM)........................................................................................ 85 RECEIVE AND TRANSMIT DIGITAL JITTER ATTENUATOR (RJAT, TJAT) ............................................................................... 86 TIMING OPTIONS (TOPS) ......................................................... 92 PSEUDO RANDOM BINARY SEQUENCE GENERATION AND DETECTION (PRBS).......................................................... 93 PSEUDO RANDOM PATTERN GENERATION AND DETECTION (PRGD).................................................................. 93 DS3 FRAMER (DS3-FRMR) ....................................................... 93 PERFORMANCE MONITOR ACCUMULATOR (DS3-PMON) .... 96 DS3 TRANSMITTER (DS3-TRAN).............................................. 96 M23 MULTIPLEXER (MX23) ....................................................... 97 DS2 FRAMER (DS2-FRMR) ....................................................... 98 M12 MULTIPLEXER (MX12) ..................................................... 100 TRIBUTARY PAYLOAD PROCESSOR (VTPP) ........................ 101 RECEIVE TRIBUTARY PATH OVERHEAD PROCESSOR (RTOP) ...................................................................................... 104
PROPRIETARY AND CONFIDENTIAL
ii
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
1.30 1.31 1.32 1.33 1.34 1.35 1.36 1.37 1.38 1.39 1.40 1.41 1.42 1.43 1.44 1.45 10 11
RECEIVE TRIBUTARY DEMAPPER (RTDM) ........................... 106 PARALLEL IN TO SERIAL OUT CONVERTER (PISO)............. 108 DS3 MAPPER DROP SIDE (D3MD) ..........................................110 TRANSMIT TRIBUTARY PATH OVERHEAD PROCESSOR (TTOP) .......................................................................................113 TRANSMIT REMOTE ALARM PROCESSOR (TRAP)...............114 TRANSMIT TRIBUTARY MAPPER (TTMP) ...............................115 SERIAL IN TO PARALLEL OUT CONVERTER (SIPO)..............116 DS3 MAPPER ADD SIDE (D3MA) .............................................116 EGRESS SYSTEM INTERFACE (ESIF) ....................................118 INGRESS SYSTEM INTERFACE (ISIF) ................................... 124 EXTRACT SCALEABLE BANDWIDTH INTERCONNECT (EXSBI) ..................................................................................... 129 INSERT SCALEABLE BANDWIDTH INTERCONNECT (INSBI)....................................................................................... 130 SCALEABLE BANDWIDTH INTERCONNECT PISO (SBIPISO).................................................................................. 130 SCALEABLE BANDWIDTH INTERCONNECT SIPO (SBISIPO).................................................................................. 131 JTAG TEST ACCESS PORT..................................................... 131 MICROPROCESSOR INTERFACE .......................................... 131
NORMAL MODE REGISTER DESCRIPTION ..................................... 162 TEST FEATURES DESCRIPTION ...................................................... 163 11.1 JTAG TEST PORT .................................................................... 172
12
OPERATION ........................................................................................ 185 12.1 DS3 FRAME FORMAT.............................................................. 185
PROPRIETARY AND CONFIDENTIAL
iii
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
12.2 12.3 12.4 12.5 12.6 12.7 12.8 12.9
SERVICING INTERRUPTS....................................................... 187 USING THE PERFORMANCE MONITORING FEATURES ...... 187 USING THE INTERNAL FDL TRANSMITTER .......................... 192 USING THE INTERNAL DATA LINK RECEIVER ...................... 196 T1 AUTOMATIC PERFORMANCE REPORT FORMAT ............ 200 USING THE PER-CHANNEL SERIAL CONTROLLERS ........... 202 T1/E1 FRAMER LOOPBACK MODES...................................... 204 DS3 LOOPBACK MODES ........................................................ 207
12.10 TELECOM BUS MAPPER/DEMAPPER LOOPBACK MODES. 210 12.11 SBI BUS DATA FORMATS .........................................................211 12.12 H-MVIP DATA FORMAT ............................................................ 230 12.13 SERIAL CLOCK AND DATA FORMAT ...................................... 236 12.14 PRGD PATTERN GENERATION .............................................. 237 12.15 JTAG SUPPORT ....................................................................... 241 13 FUNCTIONAL TIMING......................................................................... 249 13.1 13.2 13.3 13.4 13.5 13.6 13.7 13.8 13.9 DS3 LINE SIDE INTERFACE TIMING ...................................... 249 DS3 SYSTEM SIDE INTERFACE TIMING................................ 251 TELECOM DROP BUS INTERFACE TIMING........................... 253 TELECOM ADD BUS INTERFACE TIMING.............................. 256 SONET/SDH SERIAL ALARM PORT TIMING .......................... 257 SBI DROP BUS INTERFACE TIMING ...................................... 259 SBI ADD BUS INTERFACE TIMING ......................................... 260 EGRESS H-MVIP LINK TIMING ............................................... 260 INGRESS H-MVIP LINK TIMING .............................................. 261
iv
PROPRIETARY AND CONFIDENTIAL
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
13.10 EGRESS SERIAL CLOCK AND DATA INTERFACE TIMING.... 262 13.11 INGRESS SERIAL CLOCK AND DATA INTERFACE TIMING .. 267 14 15 16 17 18 19 ABSOLUTE MAXIMUM RATINGS ....................................................... 271 D.C. CHARACTERISTICS ................................................................... 272 MICROPROCESSOR INTERFACE TIMING CHARACTERISTICS..... 275 TEMUX TIMING CHARACTERISTICS ................................................ 279 ORDERING AND THERMAL INFORMATION.......................................311 MECHANICAL INFORMATION............................................................ 312
LIST OF FIGURES FIGURE 1 FIGURE 2 FIGURE 3 FIGURE 4 FIGURE 5 FIGURE 6 FIGURE 7 FIGURE 8 FIGURE 9 - CHANNELIZED DS3 CIRCUIT EMULATION APPLICATION.... 20 - HIGH DENSITY FRAME RELAY APPLICATION....................... 20 - TEMUX BLOCK DIAGRAM....................................................... 22 - M13 MULTIPLEXER BLOCK DIAGRAM................................... 23 - VT/TU MAPPER BLOCK DIAGRAM......................................... 24 - DS3 FRAMER ONLY MODE BLOCK DIAGRAM ...................... 25 - PIN DIAGRAM .......................................................................... 31 - CRC MULTIFRAME ALIGNMENT ALGORITHM....................... 74 - DJAT JITTER TOLERANCE T1 MODES .................................. 88
FIGURE 10 - DJAT JITTER TOLERANCE E1 MODES .................................. 89 FIGURE 11 - DJAT MINIMUM JITTER TOLERANCE VS. XCLK ACCURACY T1 MODES ....................................................................................... 90 FIGURE 12 - DJAT MINIMUM JITTER TOLERANCE VS. XCLK ACCURACY E1 MODES ....................................................................................... 90
PROPRIETARY AND CONFIDENTIAL
v
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
FIGURE 13 - DJAT JITTER TRANSFER T1 MODES..................................... 91 FIGURE 14 - DJAT JITTER TRANSFER E1 MODES..................................... 92 FIGURE 17 - CLOCK MASTER: NXCHANNEL.............................................119 FIGURE 18 - CLOCK MASTER: CLEAR CHANNEL.....................................119 FIGURE 19 - CLOCK SLAVE: EFP ENABLED............................................. 120 FIGURE 20 - CLOCK SLAVE: EXTERNAL SIGNALING .............................. 120 FIGURE 21 - CLOCK SLAVE: CLEAR CHANNEL ....................................... 121 FIGURE 22 - CLOCK SLAVE: H-MVIP ......................................................... 121 FIGURE 23 - CLOCK MASTER: SERIAL DATA AND H-MVIP CCS ............. 123 FIGURE 24 - CLOCK MASTER: FULL T1/E1............................................... 124 FIGURE 25 - CLOCK MASTER: NXCHANNEL............................................ 125 FIGURE 26 - CLOCK MASTER: CLEAR CHANNEL.................................... 125 FIGURE 28 - CLOCK SLAVE: EXTERNAL SIGNALING .............................. 126 FIGURE 29 - CLOCK SLAVE: H-MVIP ......................................................... 126 FIGURE 30 - CLOCK SLAVE: SERIAL DATA AND H-MVIP CCS................. 128 FIGURE 31 - DS3 FRAME STRUCTURE..................................................... 185 FIGURE 32 - FER COUNT VS. BER (E1 MODE)......................................... 189 FIGURE 33 - CRCE COUNT VS. BER (E1 MODE)...................................... 190 FIGURE 34 - FER COUNT VS. BER (T1 ESF MODE)................................. 190 FIGURE 35 - CRCE COUNT VS. BER (T1 ESF MODE) .............................. 191 FIGURE 36 - CRCE COUNT VS. BER (T1 SF MODE) ................................ 192 FIGURE 37 - TYPICAL DATA FRAME .......................................................... 199 FIGURE 38 - EXAMPLE MULTI-PACKET OPERATIONAL SEQUENCE ..... 199 FIGURE 39 - T1/E1 LINE LOOPBACK......................................................... 205
PROPRIETARY AND CONFIDENTIAL vi
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
FIGURE 40 - T1/E1 DIAGNOSTIC DIGITAL LOOPBACK ............................ 206 FIGURE 41 - PER-CHANNEL LOOPBACK ................................................. 207 FIGURE 42 - DS3 DIAGNOSTIC LOOPBACK DIAGRAM ........................... 208 FIGURE 43 - DS3 LINE LOOPBACK DIAGRAM.......................................... 209 FIGURE 44 - DS2 LOOPBACK DIAGRAM................................................... 209 FIGURE 45 - TELECOM DIAGNOSTIC LOOPBACK DIAGRAM ................. 210 FIGURE 46 - TELECOM LINE LOOPBACK DIAGRAM ................................211 FIGURE 47 - PRGD PATTERN GENERATOR ............................................. 237 FIGURE 48 - BOUNDARY SCAN ARCHITECTURE .................................... 241 FIGURE 49 - TAP CONTROLLER FINITE STATE MACHINE ...................... 243 FIGURE 50 - INPUT OBSERVATION CELL (IN_CELL) ............................... 246 FIGURE 51 - OUTPUT CELL (OUT_CELL).................................................. 247 FIGURE 52 - BIDIRECTIONAL CELL (IO_CELL)......................................... 247 FIGURE 53 - LAYOUT OF OUTPUT ENABLE AND BIDIRECTIONAL CELLS ....................................................................................... 248 FIGURE 54 - RECEIVE BIPOLAR DS3 STREAM ........................................ 249 FIGURE 55 - RECEIVE UNIPOLAR DS3 STREAM ..................................... 249 FIGURE 56 - TRANSMIT BIPOLAR DS3 STREAM ..................................... 250 FIGURE 57 - TRANSMIT UNIPOLAR DS3 STREAM................................... 250 FIGURE 58 - FRAMER MODE DS3 TRANSMIT INPUT STREAM............... 251 FIGURE 59 - FRAMER MODE DS3 TRANSMIT INPUT STREAM WITH TGAPCLK ................................................................................. 251 FIGURE 60 - FRAMER MODE DS3 RECEIVE OUTPUT STREAM ............. 252 FIGURE 61 - FRAMER MODE DS3 RECEIVE OUTPUT STREAM WITH RGAPCLK ................................................................................. 252
PROPRIETARY AND CONFIDENTIAL
vii
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
FIGURE 62 - TELECOM DROP BUS TIMING - STS-1 SPES / AU3 VCS.... 253 FIGURE 63 - TELECOM DROP BUS TIMING - LOCKED STS-1 SPES / AU3 VCS....................................................................... 254 FIGURE 64 - TELECOM DROP BUS TIMING - AU4 VC.............................. 255 FIGURE 65 - OUTPUT BUS TIMING - LOCKED STS-1 SPES / AU3 VCS.. 256 FIGURE 66 - OUTPUT BUS TIMING - LOCKED AU4 VC CASE ................. 257 FIGURE 67 - REMOTE SERIAL ALARM PORT TIMING.............................. 258 FIGURE 68 - SBI DROP BUS T1/E1 FUNCTIONAL TIMING ....................... 259 FIGURE 69 - SBI DROP BUS DS3 FUNCTIONAL TIMING ......................... 259 FIGURE 70 - SBI ADD BUS JUSTIFICATION REQUEST FUNCTIONAL TIMING...................................................................................... 260 FIGURE 71 - EGRESS 8.192 MBPS H-MVIP LINK TIMING ........................ 261 FIGURE 72 - INGRESS 8.192 MBPS H-MVIP LINK TIMING ....................... 261 FIGURE 73 - T1 EGRESS INTERFACE CLOCK MASTER: NXCHANNEL MODE........................................................................................ 262 FIGURE 74 - E1 EGRESS INTERFACE CLOCK MASTER : NXCHANNEL MODE........................................................................................ 262 FIGURE 75 - T1 AND E1 EGRESS INTERFACE CLOCK MASTER: CLEAR CHANNEL MODE...................................................................... 263 FIGURE 76 - T1 EGRESS INTERFACE CLOCK SLAVE: EFP ENABLED MODE........................................................................................ 263 FIGURE 77 - E1 EGRESS INTERFACE CLOCK SLAVE : EFP ENABLED MODE........................................................................................ 263 FIGURE 78 - T1 EGRESS INTERFACE CLOCK SLAVE: EXTERNAL SIGNALING MODE ................................................................... 264 FIGURE 79 - E1 EGRESS INTERFACE CLOCK SLAVE : EXTERNAL SIGNALING MODE ................................................................... 264
PROPRIETARY AND CONFIDENTIAL
viii
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
FIGURE 80 - T1 EGRESS INTERFACE 2.048 MHZ CLOCK SLAVE: EFP ENABLED MODE...................................................................... 265 FIGURE 81 - T1 EGRESS INTERFACE 2.048 MHZ CLOCK SLAVE: EXTERNAL SIGNALING MODE ............................................... 266 FIGURE 82 - T1 AND E1 EGRESS INTERFACE CLOCK SLAVE: CLEAR CHANNEL MODE...................................................................... 266 FIGURE 83 - T1 INGRESS INTERFACE CLOCK MASTER : FULL CHANNEL MODE...................................................................... 267 FIGURE 84 - E1 INGRESS INTERFACE CLOCK MASTER : FULL CHANNEL MODE...................................................................... 267 FIGURE 85 - T1 INGRESS INTERFACE CLOCK MASTER: NXCHANNEL MODE........................................................................................ 268 FIGURE 86 - E1 INGRESS INTERFACE CLOCK MASTER: NXCHANNEL MODE........................................................................................ 268 FIGURE 87 - T1 AND E1 INGRESS INTERFACE CLOCK MASTER: CLEAR CHANNEL MODE...................................................................... 268 FIGURE 88 - T1 INGRESS INTERFACE CLOCK SLAVE: EXTERNAL SIGNALING MODE ................................................................... 269 FIGURE 89 - E1 INGRESS INTERFACE CLOCK SLAVE: EXTERNAL SIGNALING MODE ................................................................... 269 FIGURE 90 - T1 INGRESS INTERFACE 2.048 MHZ CLOCK SLAVE: EXTERNAL SIGNALING MODE ............................................... 270 FIGURE 91 - DS3 TRANSMIT INTERFACE TIMING ................................... 281 FIGURE 92 - DS3 RECEIVE INTERFACE TIMING...................................... 284 FIGURE 93 - LINE SIDE TELECOM BUS INPUTTIMING............................ 286 FIGURE 94 - TELECOM BUS OUTPUT TIMING ......................................... 287 FIGURE 95 - TELECOM BUS TRISTATE OUTPUT TIMING ....................... 287 FIGURE 96 - SBI ADD BUS TIMING ............................................................ 289 FIGURE 97 - SBI DROP BUS TIMING ......................................................... 291
PROPRIETARY AND CONFIDENTIAL
ix
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
FIGURE 98 - SBI DROP BUS COLLISION AVOIDANCE TIMING ............... 291 FIGURE 99 - H-MVIP EGRESS DATA & FRAME PULSE TIMING............... 293 FIGURE 100 - H-MVIP INGRESS DATA TIMING ........................................... 294 FIGURE 101 - XCLK INPUT TIMING.............................................................. 295 FIGURE 102 - EGRESS INTERFACE TIMING - CLOCK SLAVE: EFP ENABLED MODE...................................................................... 297 FIGURE 103 - EGRESS INTERFACE TIMING - CLOCK SLAVE: EXTERNAL SIGNALING MODE ................................................................... 298 FIGURE 104 - EGRESS INTERFACE INPUT TIMING - CLOCK MASTER : NXCHANNEL MODE................................................................. 299 FIGURE 105 - EGRESS INTERFACE INPUT TIMING - CLOCK MASTER : CLEAR CHANNEL MODE......................................................... 300 FIGURE 106 - EGRESS INTERFACE INPUT TIMING - CLOCK MASTER : SERIAL DATA AND HMVIP CCS MODE ................................... 301 FIGURE 107 - EGRESS INTERFACE INPUT TIMING - CLOCK SLAVE : CLEAR CHANNEL MODE...................................................................... 302 FIGURE 108 - INGRESS INTERFACE TIMING - CLOCK SLAVE MODES ... 304 FIGURE 109 - INGRESS INTERFACE TIMING - CLOCK MASTER MODES 305 FIGURE 110 - TRANSMIT LINE INTERFACE TIMING .................................. 306 FIGURE 111 - REMOTE SERIAL ALARM PORT TIMING.............................. 308 FIGURE 112 - JTAG PORT INTERFACE TIMING.......................................... 310 FIGURE 113 - 324 PIN PBGA 23X23MM BODY ............................................ 312
LIST OF TABLES TABLE 1 TABLE 2 - E1-FRMR FRAMING STATES .................................................. 75 - PATH SIGNAL LABEL MISMATCH STATE ............................. 105
PROPRIETARY AND CONFIDENTIAL
x
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
TABLE 3 TABLE 4 TABLE 5 TABLE 6 TABLE 7 TABLE 8 TABLE 9 TABLE 10 TABLE 11 TABLE 12 TABLE 13 TABLE 14 TABLE 15 TABLE 16 TABLE 17 TABLE 18 TABLE 19 TABLE 20 TABLE 21 TABLE 22 TABLE 23 TABLE 24
- ASYNCHRONOUS T1 TRIBUTARY MAPPING ...................... 106 - ASYNCHRONOUS E1 TRIBUTARY MAPPING ...................... 107 - DESYNCHRONIZER CLOCK GENERATION ALGORITHM... 109 - ASYNCHRONOUS DS3 MAPPING TO STS-1 (STM-0/AU3) ..110 - DS3 AIS FORMAT. ................................................................... 111 - DS3 DESYNCHRONIZER CLOCK GAPPING ALGORITHM. ..113 - DS3 SYNCHRONIZER BIT STUFFING ALGORITHM. ............118 - REGISTER MEMORY MAP .................................................... 132 - INSTRUCTION REGISTER .................................................... 172 - IDENTIFICATION REGISTER................................................. 173 - BOUNDARY SCAN CHAIN ..................................................... 173 - PMON COUNTER SATURATION LIMITS (E1 MODE) ........... 188 - PMON COUNTER SATURATION LIMITS (T1 MODE) ........... 188 - PERFORMANCE REPORT MESSAGE STRUCTURE AND CONTENTS............................................................................... 200 - PERFORMANCE REPORT MESSAGE STRUCTURE NOTES ...................................................................................... 201 - PERFORMANCE REPORT MESSAGE CONTENTS ............. 202 - STRUCTURE FOR CARRYING MULTIPLEXED LINKS......... 213 - T1/TVT1.5 TRIBUTARY COLUMN NUMBERING ................... 213 - E1/TVT2 TRIBUTARY COLUMN NUMBERING...................... 214 - SBI T1/E1 LINK RATE INFORMATION................................... 217 - SBI T1/E1 CLOCK RATE ENCODING.................................... 217 - DS3 LINK RATE INFORMATION ............................................ 218
PROPRIETARY AND CONFIDENTIAL
xi
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
TABLE 25 TABLE 26 TABLE 27 TABLE 28 TABLE 29 TABLE 30 TABLE 31 TABLE 32 TABLE 33 TABLE 34 TABLE 35 TABLE 36 TABLE 37 TABLE 38 TABLE 39 TABLE 40 TABLE 41 TABLE 42 TABLE 43 TABLE 44 TABLE 45 TABLE 46
- DS3 CLOCK RATE ENCODING ............................................. 218 - T1 FRAMING FORMAT........................................................... 219 - T1 CHANNEL ASSOCIATED SIGNALING BITS..................... 221 - E1 FRAMING FORMAT .......................................................... 222 - E1 CHANNEL ASSOCIATED SIGNALING BITS..................... 224 - DS3 FRAMING FORMAT........................................................ 225 - DS3 BLOCK FORMAT ............................................................ 225 - DS3 MULTI-FRAME STUFFING FORMAT ............................. 226 - TRANSPARENT VT1.5/TU11 FORMAT.................................. 227 - TRANSPARENT VT2/TU12 FORMAT..................................... 229 - DATA AND CAS T1 H-MVIP FORMAT .................................... 230 - DATA AND CAS E1 H-MVIP FORMAT WITH SONET/SDH E1 MAPPING ............................................................................ 231 - DATA AND CAS E1 H-MVIP FORMAT IN G.747 MODE ......... 231 - CCS T1 H-MVIP FORMAT ...................................................... 232 - CCS E1 H-MVIP FORMAT WITH SONET/SDH E1 MAPPING.................................................................................. 233 - CCS E1 H-MVIP FORMAT IN G.747 MODE ........................... 235 - PSEUDO RANDOM PATTERN GENERATION (PS BIT = 0).. 239 - REPETITIVE PATTERN GENERATION (PS BIT = 1)............. 240 - ABSOLUTE MAXIMUM RATINGS ......................................... 271 - D.C. CHARACTERISTICS ...................................................... 272 - MICROPROCESSOR INTERFACE READ ACCESS.............. 275 - MICROPROCESSOR INTERFACE WRITE ACCESS ............ 277
PROPRIETARY AND CONFIDENTIAL
xii
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
TABLE 47 TABLE 48 TABLE 49 TABLE 50 TABLE 51 TABLE 52 TABLE 53 TABLE 54 TABLE 55 TABLE 56 TABLE 57 TABLE 58 TABLE 59 TABLE 60 TABLE 61 TABLE 62 TABLE 63 TABLE 64 TABLE 65
- RTSB TIMING ......................................................................... 279 - DS3 TRANSMIT INTERFACE TIMING ................................... 279 - DS3 RECEIVE INTERFACE TIMING...................................... 283 - LINE SIDE TELECOM BUS INPUT TIMING (FIGURE 96) ..... 285 - TELECOM BUS OUTPUT TIMING (FIGURE 97 TO FIGURE 98)............................................................................... 286 - SBI ADD BUS TIMING (FIGURE 96) ...................................... 288 - SBI DROP BUS TIMING (FIGURE 97 TO FIGURE 98) .......... 289 - H-MVIP EGRESS TIMING (FIGURE 99) ................................ 292 - H-MVIP INGRESS TIMING (FIGURE 100) ............................. 293 - XCLK INPUT (FIGURE 101) ................................................... 295 - EGRESS INTERFACE TIMING - CLOCK SLAVE: EFP ENABLED MODE (FIGURE 102) .............................................. 296 - EGRESS INTERFACE TIMING - CLOCK SLAVE: EXTERNAL SIGNALING (FIGURE 103)....................................................... 297 - EGRESS INTERFACE INPUT TIMING - CLOCK MASTER : NXCHANNEL MODE (FIGURE 104)......................................... 299 - EGRESS INTERFACE INPUT TIMING - CLOCK MASTER : CLEAR CHANNEL MODE (FIGURE 104)................................. 300 - EGRESS INTERFACE INPUT TIMING - CLOCK MASTER : SERIAL DATA AND HMVIP CCS MODE (FIGURE 104) ........... 301 - EGRESS INTERFACE INPUT TIMING - CLOCK SLAVE : CLEAR CHANNEL MODE (FIGURE 104).............................................. 302 - INGRESS INTERFACE TIMING - CLOCK SLAVE MODES (FIGURE 108) ........................................................................... 303 - INGRESS INTERFACE TIMING - CLOCK MASTER MODES (FIGURE 109) ........................................................................... 305 - TRANSMIT LINE INTERFACE TIMING (FIGURE 110)........... 306
PROPRIETARY AND CONFIDENTIAL
xiii
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
TABLE 66 TABLE 67 TABLE 68 TABLE 69
- REMOTE SERIAL ALARM PORT TIMING.............................. 307 - JTAG PORT INTERFACE ....................................................... 309 - ORDERING AND THERMAL INFORMATION..........................311 - THERMAL INFORMATION - THETA JA VS. AIRFLOW ..........311
PROPRIETARY AND CONFIDENTIAL
xiv
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
1
FEATURES * Integrates 28 T1 framers, 21 E1 framers, a SONET/SDH VT1.5/VT2/TU11/TU12 bit asynchronous mapper, a full featured M13 multiplexer with DS3 framer, and a SONET/SDH DS3 mapper in a single monolithic device for terminating DS3 multiplexed T1 streams, SONET/SDH mapped T1 streams or SONET/SDH mapped E1 streams. Seven T1 modes of operation: * Up to 28 T1 streams mapped as bit asynchronous VT1.5 virtual tributaries into a STS-1 SPE or TU-11 tributary units into a STM-1/VC3 or TU-11 tributary units into a TUG3 in a STM-1/VC4. Single STS-1, AU3 or TUG3 Bit Asynchronous VT1.5 or TU-11 Mapper with ingress or egress per tributary link monitoring. Up to 28 T1 streams M13 multiplexed into a serial DS3. Up to 28 T1 streams M13 multiplexed into a DS3, the DS3 is asynchronously mapped into a STS-1 SPE. DS3 M13 Multiplexer with ingress or egress per link monitoring. Up to 28 DS3 multiplexed T1 streams are mapped as bit asynchronous VT1.5 virtual tributaries or TU-11 tributary units, providing a transmultiplexing ("transmux") function between DS3 and SONET/SDH. Up to 21 T1 streams mapped as bit asynchronous TU-12 tributary units into a STM-1/VC3 or TUG3 from a STM-1/VC4.
*
* * * * *
* *
Three E1 modes of operation: * Up to 21 E1 streams mapped as bit asynchronous VT2 virtual tributaries into a STS-1 SPE or TU-12 tributary units into a STM-1/VC3 or TUG3 from a STM-1/VC4. Single STS-1, AU3 or TUG3 Bit Asynchronous VT2 or TU-12 Mapper with ingress or egress per tributary link monitoring. Up to 21 E1 streams multiplexed into a DS3 following the ITU-T G.747 recommendation. This E1 mode of operation is restricted to using the serial clock and data or HMVIP system interfaces.
* *
PROPRIETARY AND CONFIDENTIAL
1
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
*
Up to 28 VT1.5/TU11 or 21 VT2/TU12 tributaries can be passed between the line SONET/SDH bus and the SBI bus as transparent virtual tributaries with pointer processing. When adding and dropping T1 or E1 tributaries the mapper and demapper blocks allow for up to 28 VT1.5/TU11 or 21 VT2/TU12 tributaries to be processed from any tributary location within the full STS-3/STM-1. On the telecom DROP bus side this requires that the STS-3/STM-1 be in locked mode such that the J1 bytes immediately follow the C1 bytes. Supports transfer of PCM data to/from 1.544MHz and 2.048MHz serial interface system-side devices. Also supports a fractional T1 or E1 system interface with independent ingress/egress Nx64Kb/s rates. Supports a 2.048 MHz system-side interface for T1 mode without external clock gapping. Supports 8Mb/s H-MVIP on the system interface for all T1 or E1 links, a separate 8Mb/s H-MVIP system interface for all T1 or E1 CAS channels and a separate 8Mb/s H-MVIP system interface for all T1 or E1 CCS and V5.1/V5.2 channels. Supports a byte serial Scaleable Bandwidth Interconnect (SBI) bus interface for high density system side device interconnection of up to 84 T1 streams, 63 E1 streams or 3 DS3 streams. This interface also supports transparent virtual tributaries when used with the SONET/SDH mapper. Provides jitter attenuation in the T1 or E1 receive and transmit directions. Provides two independent de-jittered T1 or E1 recovered clocks for system timing and redundancy. Provides per-DS0 line loopback and per link diagnostic and line loopbacks. Provides an on-board programmable binary sequence generator and detector for error testing at DS3 rates. Includes support for patterns recommended in ITU-T O.151. Also provides PRBS generators and detectors on each tributary for error testing at DS1, E1 and NxDS0 rates as recommended in ITU-T O.151 and O.152. Provides robbed bit signaling extraction and insertion on a per-DS0 basis. Provides programmable idle code substitution, data and sign inversion, and digital milliwatt code insertion on a per-DS0 basis.
*
*
*
*
* * * *
*
* *
PROPRIETARY AND CONFIDENTIAL
2
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
* * *
Supports the M23 and C-bit parity DS3 formats. Standalone unchannelized DS3 framer mode for access to the entire DS3 payload. When configured to operate as a DS3 Framer, gapped transmit and receive clocks can be optionally generated for interface to link layer devices which only need access to payload data bits. DS3 Transmit clock source can be selected from either an external oscillator or from the receive side clock (loop-timed). Provides a SONET/SDH Add/Drop bus interface with integrated VT1.5, TU11, VT2 and TU-12 mapper for T1and E1 streams. Also provides a DS3 mapper. Register level compatibility with the PM4388 TOCTL Octal T1 Framer, the PM6388 EOCTL Octal E1 Framer, the PM4351 COMET E1/T1 transceiver and the PM8313 D3MX M13 Multiplexer/Demultiplexer. Provides a generic 8-bit microprocessor bus interface for configuration, control and status monitoring. Provides a standard 5 signal P1149.1 JTAG test port for boundary scan board test purposes. Low power 2.5V/3.3V CMOS technology. All pins are 5V tolerant. 324-pin fine pitch PBGA package (23mm x 23mm). Supports industrial temperature range (-40oC to 85oC) operation.
* *
*
*
* *
Each one of 28 T1 receiver sections: * * * * * * Frames to DS-1 signals in SF and ESF formats. Frames to TTC JT-G.704 multiframe formatted J1 signals. Supports the alternate CRC-6 calculation for Japanese applications. Accepts gapped data streams to support higher rate demultiplexing. Provides Red, Yellow, and AIS alarm integration. Provides ESF bit-oriented code detection and an HDLC/LAPD interface for terminating the ESF facility data link. Indicates signaling state change, and two superframes of signaling debounce on a per-DS0 basis.
PROPRIETARY AND CONFIDENTIAL
3
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
* *
Provides an HDLC interface with 128 bytes of buffering for terminating the facility data link. Provides performance monitoring counters sufficiently large as to allow performance monitor counter polling at a minimum rate of once per second. Optionally, updates the performance monitoring counters and interrupts the microprocessor once per second, timed to the receive line. Provides an optional elastic store which may be used to time the ingress streams to a common clock and frame alignment, or to facilitate per-DS0 loopbacks. Provides DS-1 robbed bit signaling extraction, with optional data inversion, programmable idle code substitution, digital milliwatt code substitution, bit fixing, and two superframes of signaling debounce on a per-channel basis.
11 15 20 A pseudo-random sequence user selectable from 2 -1, 2 -1 or2 -1, may be detected in the T1 stream in either the ingress or egress directions. The detector counts pattern errors using a 24-bit non-saturating PRBS error counter. The pseudo-random sequence can be the entire T1 or any combination of DS0s within a framed T1.
*
*
*
*
Line side interface is either from the DS3 interface via the M13 multiplex or from the SONET/SDH Drop bus via the VT1.5, TU-11, VT2 or TU-12 demapper. System side interface is either serial clock and data, MVIP or SBI bus. Frames in the presence of and detects the "Japanese Yellow" alarm. Provides external access for up to two de-jittered recovered T1 clocks.
* * *
Each one of 21 E1 receiver sections: * * * * Frames to ITU-T G.704 basic and CRC-4 multiframe formatted E1 signals. The framing procedures are consistent ITU-T G.706 specifications. Provides an HDLC interface with 128 bytes of buffering for terminating the national use bit data link. Extracts 4-bit codewords from the E1 national use bits as specified in ETS 300 233. V5.2 link indication signal detection.
PROPRIETARY AND CONFIDENTIAL
4
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
*
Provides performance monitoring counters sufficiently large as to allow performance monitor counter polling at a minimum rate of once per second. Optionally, updates the performance monitoring counters and interrupts the microprocessor once per second, timed to the receive line. Provides a two-frame elastic store buffer for backplane rate adaptation that performs controlled slips and indicates slip occurrence and direction. Frames to the E1 signaling multiframe alignment when enabled and extracts channel associated signaling. Alternatively, a common channel signaling data link may be extracted from timeslot 16. Can be programmed to generate an interrupt on change of signaling state. Provides trunk conditioning which forces programmable trouble code substitution and signaling conditioning on all channels or on selected channels.
11 15 20 A pseudo-random sequence user selectable from 2 -1, 2 -1 or2 -1, may be detected in the E1 stream in either the ingress or egress directions. The detector counts pattern errors using a 24-bit non-saturating PRBS error counter. The pseudo-random sequence can be the entire E1 or any combination of timeslots within the framed E1.
* *
* *
*
* * *
Line side interface is from the SONET/SDH Drop bus via the VT2 or TU-12 demapper. System side interface is either serial clock and data, MVIP or SBI bus. Provides external access for up to two de-jittered recovered E1 clocks.
Each one of 28 T1 transmitter sections: * May be timed to its associated receive clock (loop timing) or may derive its timing from a common egress clock or a common transmit clock; the transmit line clock may be synthesized from an N*8kHz reference. Provides minimum ones density through Bell (bit 7), GTE or "jammed bit 8" zero code suppression on a per-DS0 basis.Provides a 128 byte buffer to allow insertion of the facility data link using the host interface. Supports transmission of the alarm indication signal (AIS) or the Yellow alarm signal in both SF and ESF formats.
*
*
PROPRIETARY AND CONFIDENTIAL
5
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
* * * * *
Provides a digital phase locked loop for generation of a low jitter transmit clock. Provides a FIFO buffer for jitter attenuation and rate conversion in the transmitter. Automatically generates and transmits DS-1 performance report messages to ANSI T1.231and ANSI T1.408 specifications. Supports the alternate ESF CRC-6 calculation for Japanese applications. A pseudo-random sequence user selectable from 211 -1, 215 -1 or 220 -1, may be inserted into the T1 stream in either the ingress or egress directions. The pseudo-random sequence can be inserted into the entire T1 or any combination of DS0s within the framed T1. Line side interface is through either DS3 Interface via the M13 multiplex or the SONET/SDH Add bus via the VT1.5, TU-11, VT2 or TU-12 mapper. System side interface is either serial clock and data, MVIP or SBI bus.
* *
Each one of 21 E1 transmitter sections: * * * * * Provides a FIFO buffer for jitter attenuation and rate conversion in the transmit path. Transmits G.704 basic and CRC-4 multiframe formatted E1. Supports unframed mode and framing bit, CRC, or data link by-pass. Provides signaling insertion, programmable idle code substitution, digital milliwatt code substitution, and data inversion on a per channel basis. Provides trunk conditioning which forces programmable trouble code substitution and signaling conditioning on all channels or on selected channels. Provides a digital phase locked loop for generation of a low jitter transmit clock. A pseudo-random sequence user selectable from 211 -1, 215 -1 or 220 -1, may be inserted into the E1 stream in either the ingress or egress directions. The pseudo-random sequence can be inserted into the entire E1 or any combination of timeslots within the framed E1.
* *
PROPRIETARY AND CONFIDENTIAL
6
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
* * * * *
Optionally inserts a datalink in the E1 national use bits. Supports 4-bit codeword insertion in the E1 national use bits as specified in ETS 300 233 Supports transmission of the alarm indication signal (AIS) and the Yellow alarm signal. Line side interface is through the SONET/SDH Add bus via the VT2 or TU-12 mapper. System side interface is either serial clock and data, MVIP or SBI bus.
SONET/SDH Tributary Path Processing Section: * * Interfaces with a byte wide Telecom Add/Drop bus, interfacing directly with the PM5362 TUPP-PLUS and PM5342 SPECTRA-155. Compensates for pleisiochronous relationships between incoming and outgoing higher level (STS-1, AU4, AU3) synchronous payload envelope frame rates through processing of the lower level tributary pointers. Optionally frames to the H4 byte in the path overhead to determine tributary multi-frame boundaries and generates change of loss-of-frame status interrupts. Detects loss of pointer (LOP) and re-acquisition for each tributary and optionally generates interrupts. Detects tributary path alarm indication signal (AIS) and return to normal state for each tributary and optionally generates interrupts Detects tributary elastic store underflow and overflow and optionally generates interrupts. Provides individual tributary path signal label register that hold the expected label and detects tributary path signal label mismatch alarms (PSLM) and return to matched state for each tributary and optionally generates interrupts. Detects tributary path signal label unstable alarms (PSLU) and return to stable state for each tributary and optionally generates interrupts. Detects assertion and removal of tributary extended remote defect indications (RDI) for each tributary and optionally generates interrupts.
*
* * * *
* *
PROPRIETARY AND CONFIDENTIAL
7
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
*
Calculates and compares the tributary path BIP-2 error detection code for each tributary and configurable to accumulate the BIP-2 errors on block or bit basis in internal registers. Allows insertion of all-zeros or all-ones tributary idle code with unequipped indication and valid pointer into any tributary under SW control. Allows SW to force the AIS insertion on a per tributary basis. Inserts valid H4 byte and all-zeros fixed stuff bytes. Remaining path overhead bytes (J1, B3, C2,G1, F2, Z3, Z4, Z5) are set to all-zeros. Inserts valid pointers and all-zeros transport overhead bytes on the outgoing telecom Add bus, with valid control signals. Support in-band error reporting by updating the FEBE, RDI and auxiliary RDI bits in the V5 byte with the status of the incoming stream and remote alarm pins. Calculates and inserts the tributary path BIP-2 error detection code for each tributary.
* * * * *
*
SONET/SDH VT/TU Mapper Section: * * * * * Inserts up to 28 bit asynchronous mapped VT1.5 virtual tributaries into an STS-1 SPE from T1 streams. Inserts up to 28 bit asynchronous mapped TU-11 tributary units into a STM1/VC4 TUG3 or STM-1/VC3 from T1 streams. Inserts up to 21 bit asynchronous mapped VT2 virtual tributaries into an STS1 SPE from E1 streams. Inserts up to 21 bit asynchronous mapped TU-12 tributary units into an STM1/VC4 TUG3 or STM-1/VC3 from E1 or T1 streams. Bit asynchronous mapping assigns stuff control bits for all streams independently using an all digital control loop. Stuff control bits are dithered to produce fractional mapping jitter at the receiving desynchronizer. Sets all fixed stuff bits for asynchronous mappings to zeros or ones per microprocessor control
*
PROPRIETARY AND CONFIDENTIAL
8
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
* *
Extracts up to 28 bit asynchronous mapped VT1.5 virtual tributaries from an STS-1 SPE into T1 streams via an optional elastic store. Extracts up to 28 bit asynchronous mapped TU-11 tributary units from an STM-1/VC4 TUG3 or STM-1/VC3 into T1 streams via an optional elastic store. Extracts up to 21 bit asynchronous mapped VT2 virtual tributaries from an STS-1 SPE into E1 streams via an optional elastic store. Extracts up to 21 bit asynchronous mapped TU-12 tributary units from an STM-1/VC4 TUG3 or STM-1/VC3 into E1 or T1 streams via an optional elastic store. Demapper ignores all transport overhead bytes, path overhead bytes and stuff (R) bits Performs majority vote C-bit decoding to detect stuff requests.
* *
* *
SONET/SDH DS3 Mapper Section: * * * * * * Maps a DS3 stream into an STS-1 SPE (AU3). Sets all fixed stuff (R) bits to zeros or ones per microprocessor control Extracts a DS3 stream from an STS-1 SPE (AU3). Demapper ignores all transport overhead bytes, path overhead bytes and stuff (R) bits Performs majority vote C-bit decoding to detect stuff requests Complies with DS3 to STS-1 asynchronous mapping standards
DS3 Receiver Section: * Frames to a DS3 signal with a maximum average reframe time of less than 1.5 ms (as required by TR-TSY-000009 Section 4.1.2 and TR-TSY-000191 Section 5.2). Decodes a B3ZS-encoded signal and indicates line code violations. The definition of line code violation is software selectable.
*
PROPRIETARY AND CONFIDENTIAL
9
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
*
Provides indication of M-frame boundaries from which M-subframe boundaries and overhead bit positions in the DS3 stream can be determined by external processing. Detects the DS3 alarm indication signal (AIS) and idle signal. Detection algorithms operate correctly in the presence of a 10-3 bit error rate.Extracts valid X-bits and indicates far end receive failure (FERF).Accumulates up to 65,535 line code violation (LCV) events per second, 65,535 P-bit parity error events per second, 1023 F-bit or M-bit (framing bit) events per second, 65,535 excessive zero (EXZ) events per second, and when enabled for C-bit parity mode operation, up to 16,383 C-bit parity error events per second, and 16,383 far end block error (FEBE) events per second. Detects and validates bit-oriented codes in the C-bit parity far end alarm and control channel. Terminates the C-bit parity path maintenance data link with an integral HDLC receiver having a 128-byte deep FIFO buffer with programmable interrupt threshold. Supports polled or interrupt-driven operation. Selectable none, one or two address match detection on first byte of received packet. Programmable pseudo-random test-sequence detection-(up to 232 -1 bit length patterns conforming to ITU-T O.151 standards) and analysis features.
*
* *
*
DS3 Transmit Section: * * Provides the overhead bit insertion for a DS3 stream. Provides a bit serial clock and data interface, and allows the M-frame boundary and/or the overhead bit positions to be located via an external interface Provides B3ZS encoding. Generates an B3Zs encoded 100... repeating pattern to aid in pulse mask testing. Inserts far end receive failure (FERF), the DS3 alarm indication signal (AIS) and the idle signal when enabled by internal register bits. Provides optional automatic insertion of far end receive failure (FERF) on detection of loss of signal (LOS), out of frame (OOF), alarm indication signal (AIS) or red alarm condition.
* * * *
PROPRIETARY AND CONFIDENTIAL
10
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
*
Provides diagnostic features to allow the generation of line code violation error events, parity error events, framing bit error events, and when enabled for the C-bit parity application, C-bit parity error events, and far end block error (FEBE) events. Supports insertion of bit-oriented codes in the C-bit parity far end alarm and control channel. Optionally inserts the C-bit parity path maintenance data link with an integral HDLC transmitter. Supports polled and interrupt-driven operation. Provides programmable pseudo-random test sequence generation (up to 232-1 bit length sequences conforming to ITU-T O.151 standards) or any repeating pattern up to 32 bits. The test pattern can be framed or unframed. Diagnostic abilities include single bit error insertion or error insertion at bit error rates ranging from 10-1 to 10-7.
* * *
M23 Multiplexer Section: * * * * * * * Multiplexes 7 DS2 bit streams into a single M23 format DS3 bit stream. Performs required bit stuffing/destuffing including generation and interpretation of C-bits. Includes required FIFO buffers for rate adaptation in the multiplex path. Allows insertion and detection of per DS2 payload loopback requests encoded in the C-bits to be activated under microprocessor control. Internally generates DS2 clock for use in integrated M13 or C-bit parity multiplex applications. Alternatively accepts external DS2 clock reference. Allows per DS2 alarm indication signal (AIS) to be activated or cleared for either direction under microprocessor control. Allows DS2 alarm indication signal (AIS) to be activated or cleared in the demultiplex direction automatically upon loss of DS3 frame alignment or signal. Supports C-bit parity DS3 format.
*
PROPRIETARY AND CONFIDENTIAL
11
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
DS2 Framer Section: * Frames to a DS2 (ANSI T1.107 section 8) signal with a maximum average reframe time of less than 7 ms (as required by TR-TSY-000009 Section 4.1.2 and TR-TSY-000191 Section 5.2). Detects the DS2 alarm indication signal (AIS) in 9.9 ms in the presence of a 10-3 bit error rate. Extracts the DS2 X-bit remote alarm indication (RAI) bit and indicates far end receive failure (FERF). Accumulates up to 255 DS2 M-bit or F-bit error events per second.
* * *
DS2 Transmitter Section: * * * Generates the required X, F, and M bits into the transmitted DS2 bit stream. Allows inversion of inserted F or M bits for diagnostic purposes. Provides for transmission of far end receive failure (FERF) and alarm indication signal (AIS) under microprocessor control. Provides optional automatic insertion of far end receive failure (FERF) on detection of out of frame (OOF), alarm indication signal (AIS) or red alarm condition.
M12 Multiplexer Section: * * * * * * Multiplexes four DS1 bit streams into a single M12 format DS2 bit stream. Performs required bit stuffing including generation and interpretation of Cbits. Includes required FIFO buffers for rate adaptation in the multiplex path. Performs required inversion of second and fourth multiplexed DS1 streams as required by ANSI T1.107 Section 7.2. Allows insertion and detection of per DS1 payload loopback requests encoded in the C-bits to be activated under microprocessor control. Allows per tributary alarm indication signal (AIS) to be activated or cleared for either direction under microprocessor control.
PROPRIETARY AND CONFIDENTIAL
12
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
*
Allows automatic tributary AIS to be activated upon DS2 out of frame.
Synchronous System Interfaces: * Provides seven 8Mb/s H-MVIP data interfaces for synchronous access to all the DS0s of all 28 T1 links or all timeslots of all 21 E1s. T1 DS0s are bundled from four T1 links in sequential order (i.e. 1-4, 5-8, 9-12, 13-16, 17-20, 21-24, 25-28). In normal mode, E1 timeslots are bundled from 4 E1 links in sequential order (i.e. 1-4, 5-8, 9-12, 13-16, 17-20 and 21 by itself). In G.747 mode, E1 timeslots are bundled from 3 E1 links in sequential order, spaced by a reserved timeslot on every 4th frame (i.e. 1-3/X, 4-6/X, 7-9/X, 10-12/X, 13-15/X, 16-18/X, 19-21/X). Provides seven 8Mb/s H-MVIP interfaces for synchronous access to all channel associated signaling (CAS) bits for all T1 DS0s or E1 timeslots. The CAS bits occupy one nibble of every byte on the H-MVIP interfaces and are repeated over the entire T1 or E1 multi-frame. Provides a single 8Mb/s H-MVIP interface for common channel signaling (CCS) channels as well as V5.1 and V5.2 channels. In T1 mode DS0 24 is available through this interface. In E1 mode timeslots 15, 16 and 31 are available through this interface. All links accessed via the H-MVIP interface will be synchronously timed to the common HMVIP clock and frame alignment signals, CMV8MCLK, CMVFP, CMVFPC. H-MVIP access for Channel Associated Signaling is available with the Scaleable Bandwidth Interconnect bus as an optional replacement for CAS access over the SBI bus as well as with the H-MVIP data interface. Common Channel Signaling H-MVIP access is available with the SBI bus, serial PCM and H-MVIP data interfaces. Compatible with H-MVIP PCM backplanes supporting 8.192 Mbit/s.
*
*
*
*
*
Scaleable Bandwidth Interconnect (SBI) Bus: * Provides a high density byte serial interconnect for all framed and unframed TEMUX links. Utilizes an Add/Drop configuration to asynchronously mutliplex up to 84 T1s, 63 E1s or 3 DS3s, equivalent to three TEMUXs, with multiple payload or link layer processors. External devices can access unframed DS3, framed unchannelized DS3, unframed (clear channel) T1s, framed T1s, unframed (clear channel) E1s,
*
PROPRIETARY AND CONFIDENTIAL
13
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
framed E1s, transparent virtual tributaries or transparent tributary units over this interface. * * * * Framed and unframed T1 access can be selected on a per T1 basis. Framed and unframed E1 access can be selected on a per E1 basis. Synchronous access for T1 DS0 channels or E1 timeslots is supported in a locked format mode. Transparent VT/TU access can be selected only when tributaries are mapped into SONET/SDH. Transparent VT1.5s and TU-11s can be selected on a per tributary basis in combination with framed and unframed T1s. Transparent VT2s and TU-12s can be selected on a per tributary basis in combination with framed and unframed E1s. Channel associated signaling bits for channelized T1 and E1 are explicitly identified across bus. Transmit timing is mastered either by the TEMUX or a layer 2 device connecting to the SBI bus. Timing mastership is selectable on a per tributary basis, where a tributary is either an individual T1, E1 or a DS3.
* *
PROPRIETARY AND CONFIDENTIAL
14
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
2
APPLICATIONS * * * * * * * * High density T1 interfaces for multiplexers, multi-service switches, routers and digital modems. High density E1 interfaces for multiplexers, multi-service switches, routers and digital modems. Frame Relay switches and access devices (FRADS) SONET/SDH Add Drop Multiplexers SONET/SDH Terminal Multiplexers M23 Based M13 Multiplexer C-Bit Parity Based M13 Multiplexer Channelized and Unchannelized DS3 Frame Relay Interfaces
PROPRIETARY AND CONFIDENTIAL
15
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
3 * *
REFERENCES American National Standard for Telecommunications - Digital Hierarchy Synchronous DS3 Format Specifications, ANSI T1.103-1993 American National Standard for Telecommunications - ANSI T1.105 - "Synchronous Optical Network (SONET) - Basic Description Including Multiplex Structure, Rates, and Formats," October 27, 1995. American National Standard for Telecommunications - ANSI T1.105.02 - "Synchronous Optical Network (SONET) - Payload Mappings," October 27, 1995. American National Standard for Telecommunications - Digital Hierarchy Formats Specification, ANSI T1.107-1995 American National Standard for Telecommunications - Digital Hierarchy - Layer 1 In-Service Digital Transmission Performance Monitoring, ANSI T1.231-1997 American National Standard for Telecommunications - Carrier to Customer Installation - DS-1 Metallic Interface Specification, ANSI T1.403-1995 American National Standard for Telecommunications - Customer Installation-toNetwork - DS3 Metallic Interface Specification, ANSI T1.404-1994 American National Standard for Telecom-unications - Integrated Services Digital Network (ISDN) Primary Rate- Customer Installation Metallic Interfaces Layer 1 Specification, ANSI T1.408-1990 Bell Communications Research, TR-TSY-000009 - Asynchronous Digital Multiplexes Requirements and Objectives, Issue 1, May 1986 Bell Communications Research - DS-1 Rate Digital Service Monitoring Unit Functional Specification, TA-TSY-000147, Issue 1, October, 1987 Bell Communications Research - Alarm Indication Signal Requirements and Objectives, TR-TSY-000191 Issue 1, May 1986 Bell Communications Research - Wideband and Broadband Digital CrossConnect Systems Generic Criteria, TR-NWT-000233, Issue 3, November 1993 Bellcore GR-253-CORE - "SONET Transport Systems: Common Criteria," Issue 2, Revision 1, December 1997.
*
* * * * *
* * * * *
PROPRIETARY AND CONFIDENTIAL
16
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
*
Bell Communications Research - Integrated Digital Loop Carrier Generic Requirements, Objectives, and Interface, TR-NWT-000303, Issue 2, December, 1992 Bell Communications Research - Transport Systems Generic Requirements (TSGR): Common Requirement, TR-TSY-000499, Issue 5, December, 1993 Bell Communications Research - OTGR: Network Maintenance Transport Surveillance - Generic Digital Transmission Surveillance, TR-TSY-000820, Section 5.1, Issue 1, June 1990 AT&T - Requirements For Interfacing Digital Terminal Equipment To Services Employing The Extended Superframe Format, TR 54016, September, 1989. AT&T - Accunet T1.5 - Service Description and Interface Specification, TR 62411, December, 1990 ITU Study Group XVIII - Report R 105, Geneva, 9-19 June 1992 ETSI - ETS 300 011 - ISDN Primary Rate User-Network Interface Specification and Test Principles, 1992. ETSI - ETS 300 233 - Access Digital Section for ISDN Primary Rates, May 1994 ETSI - ETS 300 324-1 - Signaling Protocols and Switching (SPS); V interfaces at the Digital Local Exchange (LE) V5.1 Interface for the Support of Access Network (AN) Part 1: V5.1 Interface Specification, February, 1994. ETSI - ETS 300 347-1 - Signaling Protocols and Switching (SPS); V Interfaces at the Digital Local Exchange (LE) V5.2 Interface for the Support of Access Network (AN) Part 1: V5.2 Interface Specification, September 1994. ETSI ETS 300 417-1-1 - "Transmission and Multiplexing (TM); Generic Functional Requirements for Synchronous Digital Hierarchy (SDH) equipment; Part 1-1: Generic processes and performance," January, 1996. ETSI, Generic Functional Requirements for Synchronous Digital Hierarchy (SDH) Equipment, Jan 1996 ITU-T - Recommendation G.704 - Synchronous Frame Structures Used at Primary Hierarchical Levels, July 1995. ITU-T - Recommendation G.706 - Frame Alignment and CRC Procedures Relating to G.704 Frame Structures, 1991.
* *
* * * * * *
*
*
* * *
PROPRIETARY AND CONFIDENTIAL
17
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
* * * * * * *
ITU-T - Recommendation G.732 - Characteristics of Primary PCM Multiplex Equipment Operating at 2048 kbit/s, 1993. ITU-T Recommendation G.707 - Network Node Interface for the Synchronous Digital Hierarchy, 1996 ITU-T Recommendation G.747 - Second Order Digital Multiplex Equipment Operating at 6312kbit/s and Multiplexing Three Tributaries at 2048 kbit/s, 1988 ITU-T Recommendation G.775, - Loss of Signal (LOS) and Alarm Indication Signal (AIS) Defect Detection and Clearance Criteria, 11/94 ITU-T Recommendation G.783 - "Characteristics of Synchronous Digital Hierarchy (SDH) Equipment Functional Blocks," April, 1997. ITU-T Recommendation G.823, - The Control of Jitter and Wander within Digital Networks which are Based on the 2048 kbit/s Hierarchy, 03/94 ITU-T Recommendation G.964, - V-Interfaces at the Digital Local Ex-hange (LE) - V5.1 Interface (Based on 2048 kbit/s) for the Support of Access Network (AN), June 1994. ITU-T Recommendation G.965, - V-Interfaces at the Digital Local Ex-hange (LE) - V5.2 Interface (Based on 2048 kbit/s) for the Support of Access Network (AN), March -995. ITU-T - Recommend-tion I.431 - Primary Rate User-Network Interface - Layer 1 Specification, 1993. ITU-T Recommendation O.151 - Error Performance Measuring Equipment Operating at the Primary Rate and Above, October 1992 ITU-T Recommendation O.152 - Error Performance Measuring Equipment for Bit Rates of 64 kbit/s and N x 64 kbit/s, October 1992 ITU-T Recommendation O.153 - Basic Parameters for the Measurement of Error Performance at Bit Rates below the Primary Rate, October 1992. ITU-T Recommendation Q.921 - ISDN User-Network Interface Data Link Layer Specification, March 1993 International Organization for Standardization, ISO 3309:1984 - High-Level Data Link Control procedures - Frame Structure
*
* * * * * *
PROPRIETARY AND CONFIDENTIAL
18
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
* * * * * * *
PMC-Sierra Inc., PMC-1980577 - Saturn Compatible Scaleable Bandwidth Interface (SBI) Specification, Issue 3, 1998 TTC Standard JT-G704 - Frame Structures on Primary and Secondary Hierarchical Digital Interfaces, 1995. TTC Standard JT-G706 - Frame Synchronization and CRC Procedure TTC Standard JT-I431 - ISDN Primary Rate User-Network Interface Layer 1 Specification, 1995. Nippon Telegraph and Telephone Corporation - Technical Reference for HighSpeed Digital Leased Circuit Services, Third Edition, 1990. GO-MVIP, Multi-Vendor Integration Protocol, MVIP-90, Release 1.1, 1994 GO-MVIP, H-MVIP Standard, Release1.1a, 1997
PROPRIETARY AND CONFIDENTIAL
19
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
4
APPLICATION EXAMPLES Figure 1 - Channelized DS3 Circuit Emulation Application
DS3 LIU
PM8315 TEMUX
28 T1/21 E1 Framer M13 Mux, DS3 framer
PM73122 AAL1gator-32 ATM SAR
DS3 LIU
PM8315 TEMUX
28 T1/21 E1 Framer M13 Mux, DS3 framer
PM73122 AAL1gator-32 ATM SAR
DS3 LIU
PM8315 TEMUX
28 T1/21 E1 Framer M13 Mux, DS3 framer
SBI Bus
PM73122 AAL1gator-32 ATM SAR
Utopia Bus
Figure 2
- High Density Frame Relay Application
STS-3/ STM-1
PM5342 SPECTRA 155 Payload Extractor/ Aligner
PM8315 TEMUX #3 PM8315 TEMUX #2 PM8315 TEMUX #1
in VT1.5 or VT2.0 Mapper Mode Mapper and Telecom Bus I/F T1 Framer #28 or E1 Framer #21
...
PM7384 FREEDM 84P672 High Density HDLC Controller
T1 or E1 Framer #1
SBI Bus PCI Bus
High Density T1/E1 Frame Relay Port Card
PROPRIETARY AND CONFIDENTIAL
20
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
5 5.1
BLOCK DIAGRAM Top Level Block Diagram Figure 3 shows the complete TEMUX. T1 links can be multiplexed into the DS3 or can be mapped into the telecom bus as SONET VT1.5 virtual tributaries or as SDH TU-11 or TU-12 tributary units, shown at the bottom of the diagram. E1 links can be mapped into the telecom bus as SONET VT2 virtual tributaries or as SDH TU-12 tributary units, shown at the bottom of the diagram. System side access to the T1s and E1s is available as serial clock and data, Synchronous MVIP interfaces or the SBI bus. DS3 line side access is via the clock and data interface for line interface units or DS3 mapped into the SONET/SDH telecom bus. Unchannelized DS3 system side access is available through a serial clock and data interface or the SBI bus, both shown at the top of the diagram.
PROPRIETARY AND CONFIDENTIAL
21
DATASHEET
PMC-1981125
STANDARD PRODUCT
A[13:0 ] D[7:0] RDB W RB CSB ALE INTB RS TB
MPIF MicroProcessor Inte rface
XCLK CTCLK
Figure 3
CLK 52M
TOPS Timing Options TJAT Digita l Jitter Attenuator T1-XBAS/E1-TRAN BasicTransm itte r: Frame G ene ration, Alarm Insertion, Signaling Insertion, Trunk Conditioning TPSC Per-DS0 Controller ESIF Egress System Interface
D3M D
CE CLK /CMV8M CLK CEFP/CMV FPB ED[1:28] ECLK [1:28]/ EFP [1:28]/ ESIG[1:28]
DS3 Drop Side M apper RTO P Receive Tributary Path O/H Processor RTDM Receive Tributary DeM apper XBOC TDPR Bit O riented HDLC Code G enerator Transmitter SBIPISO Parallel to Serial SBI Egress Bus EXSBI PIS O Dem apper Parallel to Serial Converter
PROPRIETARY AND CONFIDENTIAL
MV ED[1:7] CA SE D[1:7] CCSED
TRAP Transm it Rem ote Alarm Processor TTMP Transm it Tributary M apper SIP O Serial to Parallel Converter
LDDATA[7:0] LDC1J1 LDD P LDP L LD TPL LDV 5 LDAIS
VTPP VT/TU Payload Processor
RADEA ST RA DEA SLCK RA DE AST FP RA DW E ST RADW E STCK RADW EST FP
SAD ATA[7:0] SA DP S AP L S AV 5 SAJUST _REQ
LA DATA[7:0] LADP LAP L LA C1J 1V1 LAOE LA C1 LR EFCLK
VTPP Transm it VT/TU Payload Processor
TTOP Transm it Tributary PathO/H Processor
T1-APRM
ISSUE 7
PMON Performance Monitor Counters
RDLC HDLC Receiver Auto Performance Response Monitor
PRBS Pattern Generator/ Detector SBISIPO Serial to Parallel
INSBI SBI Ingress Bus
SRE FCLK SC1FP SDDATA[7:0] SDD P SDP L SDV 5 SBIACT SBIDE T[1:0]
D3M A DS3 Add Side Mapper
RBOC Bit Oriented Code Detector
ALM I Alarm Integrator TDPR Tx HDLC
XBOC Tx FEAC
#1
B3ZS
ID[1:28] IFP[1:28]
ISIF Ingress System Interface
TICLK TCLK TPOS/TDA T TNEG/TMFP
TRAN DS3 Tra nsmit Framer SIG X Signaling Extractor RPSC Per-DS0 Controller MX23 M23 MUX/ DEMUX RJAT Digital Jitter Attenuator
Encode
FRMR MX12 M12 DS2 Framer MUX/ DEMUX
ELST Elastic Store
T1/E1-FRMR Frame Alignm ent, Alarm Extraction
ICLK[1:28]/ ISIG[1:28]
- TEMUX Block Diagram
B3ZS Receive Framer RDLC Rx HDLC Monitor PMON Perf.
22
One of Seven FRMR/M12s
One of 28 T1 or 21 E 1 Fram ers FRAM Framer RAM
Decode
FRM R DS3
MVID[1:7] CASID[1:7] CCSID CIFP CICLK/C MVFP C
RCLK RPOS/RDAT RNEG/R LCV
RBO C Rx
FEAC
REC VC LK1 REC VC LK2
TDO TD I TCLK TMS TRS TB
JTAG Test Access Port
TFPO/T MFPO/ TGAPC LK TDATI TFPI/TMFPI RG AP CLK /RSCLK RD ATO RFPO/RMFPO RO VR HD
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
PM8315 TEMUX
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
5.2
M13 Multiplexer Mode Block Diagram Figure 4 shows the TEMUX, configured as a M13 multiplexer, connected to a synchronous MVIP system side bus. In this example the TEMUX provides synchronous access to the fully channelized T1s (access to all DS0s) multiplexed into the DS3. There is also synchronous MVIP access to all channel associated signaling channels (CAS). An additional MVIP interface can be used to provide synchronous access to the common channel signaling channels (CCS), although this same information is available within the data MVIP signals. Figure 4 - M13 Multiplexer Block Diagram
XCLK CTCLK
CM V8M CLK CM VFPB
TO PS Timing O ptions TJAT Digital Jitter A ttenuator T1-X BAS/E1-T RAN BasicTransm itter: Frame G eneration, A larm Insertion, Signaling Ins ertion, Trunk Conditioning TP SC P er-DS 0 Controller ESIF Egress System Interface
MVED [1:7] CASED[1:7] CCSED
XB OC TDPR Bit O riented HDLC Code G enerator Transmitter
PM ON Performance Monitor Counters
RDLC HDLC Receiver
Auto Performance Response Monitor
T1-APRM
P RBS Pattern Generator/ Detector
X BOC Tx FE AC
T DPR Tx H DLC TRAN DS 3 Transm it Framer M X 23 M23 MU X/ DEMUX
RBOC Bit Oriented Code Detector
ALM I Alarm Integrator
TIC LK TC LK TPO S/TDAT TN EG/T MFP
#1
MVID[1:7]
T1/E1-FR MR Frame A lignm ent, A larm Extraction ISIF Ingress System Interface
B3ZS Encode
B3ZS
RC LK RPOS/RD AT RN EG /RLCV
Decode
FRM R DS 3 Receiv e Framer
FRMR MX12 M12 DS2 Framer MUX/ DEMUX
CASID [1:7] CCSID
RJAT Digital Jitter A ttenuator
One of Seven FRMR/M12s
RB OC Rx FEAC
R DLC Rx HDLC
PM ON Perf. Monitor
One of 28 T1 or 21 E1 Fram ers
FRAM Framer RAM
ELST Elastic Store
S IG X Signaling E xtractor
RPSC Per-DS0 Controller
CIFP CICLK/CMVFPC REC VC LK1 REC VC LK2
5.3
VT/TU Mapper Only Mode Block Diagram Figure 5 shows the TEMUX configured as a VT or TU mapper. In this mode the TEMUX bypasses the T1 and E1 framers and provides access for up to 28 independent unframed 1.544Mb/s streams or 21 independent unframed 2.048Mb/s streams. The 1.544Mb/s and 2.048Mb/s streams can be accessed on the system side as clock and data as shown in Figure 5, or they can be accessed via the SBI bus. The T1 or E1 framers and performance monitoring blocks can be used to monitor the passing traffic in either the ingress or egress direction. The M13 Multiplexer mode operates in much the same way as the VT and TU mapper shown in Figure 5.
PROPRIETARY AND CONFIDENTIAL
23
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Figure 5
- VT/TU Mapper Block Diagram
XCLK
LDDATA[7:0] LDC1J1 LDDP LDPL LDTPL LDV5 LDAIS LADATA[7:0] LADP LAPL LAC1J1V1 LAOE LAC1 LREFCLK RADEAST RADEASLCK RADEASTFP RADW EST RADW ESTCK RADW ESTFP
VTPP VT Payload Processor
RTOP Receive Tributary Path O/H Processor
RTDM Receive Tributary DeMapper
PISO Parallel to Serial Converter SIPO Serial to Parallel Converter TJAT Digital Jitter Attenuator
ECLK[1:28] ED[1:28]
TRAP/ TTMP VTPP TTOP Transmit VT Transmit Tributary Payload Mapper Processor Remote Alarm & Tributary PathO/H Processors
PMON ALMI Performance Alarm Monitor Integrator Counters
RJAT Digital Jitter Attenuator
T1/E1-FRMR Framer: Frame Alignment, Alarm Extraction
One of 28 T1 or 21 E1 Framers
ID[1:28] ICLK[1:28]
RECVCLK1 RECVCLK2
5.4
DS3 Framer Only Block Diagram Figure 6 shows the TEMUX configured as a DS3 framer. In this mode the TEMUX provides access to the full DS3 unchannelized payload. The payload access (right side of diagram) has two clock and data interfacing modes, one utilizing a gapped clock to mask out the DS3 overhead bits and the second utilizing an ungapped clock with overhead indications on a separate overhead signal. The SBI bus can also be used to provide access to the unchannelized DS3.
PROPRIETARY AND CONFIDENTIAL
24
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Figure 6
- DS3 Framer Only Mode Block Diagram
TDP R Tx HD LC TIC LK TCLK TPO S/TD AT TNEG/TM FP TRAN DS3 Transm it Fram er FRM R DS3 R eceive Fram er PM ON Perf. M onitor
B3ZS E ncode
TD A TI TFP O/TMFPO /TG APC LK TFP I/T M FP I RG APCLK/RSCLK RD ATO RFPO /R MFPO RO VRHD
RCLK RPOS /RD AT RNEG /R LC V
B3ZS D ecode
RDLC Rx HDLC
PROPRIETARY AND CONFIDENTIAL
25
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
6
DESCRIPTION The PM8315 High Density T1/E1 Framer with Integrated VT/TU Mapper and M13 Multiplexer (TEMUX) is a feature-rich device for use in any applications requiring high density link termination over T1 channelized DS3 or T1 and E1 channelized SONET/SDH facilities. The TEMUX supports asynchronous multiplexing and demultiplexing of 28 DS1s into a DS3 signal as specified by ANSI T1.107 and Bell Communications Research TR-TSY-000009. It supports bit asynchronous mapping and demapping of 28 T1s or 21 E1s into SONET/SDH as specified by ANSI T1.105, Bell Communications Research GR-253-CORE and ITU-T Recommendation G.707. The TEMUX also supports mapping of 21 T1s into SDH via TU-12s. Up to 28 Transparent VT1.5s and TU-11s or 21 Transparent VT2s and TU-12s can be transferred between the SONET/SDH interface and the SBI bus interface. This device can also be configured as a DS3 framer, providing external access to the full DS3 payload, or a VT/TU mapper, providing access to unframed 1.544Mb/s and 2.048Mb/s links. The TEMUX can be used as a SONET/SDH VT/TU mapper or M13 multiplexer with performance monitoring in either the ingress or egress direction for up to 28 T1s or 21 E1s. In this configuration the T1 and E1 transmit framers are disabled and either the ingress or egress T1 or E1 signals are routed to the T1 or E1 framers for performance monitoring purposes. Each of the T1 and E1 framers and transmitters is independently software configurable, allowing timing master and feature selection without changes to external wiring. This device is able to operate in T1 mode or E1 mode but not a mix of T1 and E1 modes. In the ingress direction, each of the 28 T1 framers is either demultiplexed from a channelized DS3 or extracted from SONET VT1.5, TU-11 or TU-12 mapped bus. Each T1 framer can be configured to frame to either of the common DS1 signal formats: (SF, ESF) or to be bypassed (unframed mode). Each T1 framer detects and indicates the presence of Yellow and AIS patterns and also integrates Yellow, Red, and AIS alarms. T1 performance monitoring with accumulation of CRC-6 errors, framing bit errors, out-of-frame events, and changes of frame alignment is provided. The TEMUX also detects the presence of ESF bit oriented codes, and detects and terminates HDLC messages on the ESF data link. The HDLC messages are terminated in a 128 byte FIFO. An elastic store that optionally supports slip buffering and adaptation to backplane timing is provided, as is a signaling
PROPRIETARY AND CONFIDENTIAL
26
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
extractor that supports signaling debounce, signaling freezing and interrupt on signaling state change on a per-DS0 basis. The TEMUX also supports idle code substitution, digital milliwatt code insertion, data extraction, trunk conditioning, data sign and magnitude inversion, and pattern generation or detection on a perDS0 basis. In the egress direction, framing is generated for 28 T1s into either a DS3 multiplex or a SONET/SDH mapped add bus. Each T1 transmitter frames to SF or ESF DS1 formats, or framing can be optionally disabled. The TEMUX supports signaling insertion, idle code substitution, data insertion, line loopback, data inversion and zero-code suppression on a per-DS0 basis. PRBS generation or detection is supported on a framed and unframed T1 basis. In the ingress direction, each of the 21 E1 framers is extracted from SONET/SDH VT2 or TU-12 mapped bus. Each E1 framer detects and indicates the presence of remote alarm and AIS patterns and also integrates Red and AIS alarms. The E1 framers support detection of various alarm conditions such as loss of frame, loss of signaling multiframe and loss of CRC multiframe. The E1 framers also support reception of remote alarm signal, remote multiframe alarm signal, alarm indication signal, and time slot 16 alarm indication signal. E1 performance monitoring with accumulation of CRC-4 errors, far end block errors and framing bit errors is provided. The TEMUX provides a receive HDLC controller for the detection and termination of messages on the national use bits. Detection of the 4-bit Sa-bit codewords defined in ITU-T G.704 and ETSI 300233 is supported. V5.2 link ID signal detection is also supported. An interrupt may be generated on any change of state of the Sa codewords. An elastic store for slip buffering and rate adaptation to backplane timing is provided, as is a signaling extractor that supports signaling debounce, signaling freezing, idle code substitution, digital milliwatt tone substitution, data inversion, and signaling bit fixing on a per-channel basis. Receive side data and signaling trunk conditioning is also provided. In the egress direction, framing is generated for 21 E1s into a SONET/SDH mapped add bus. Each E1 transmitter generates framing for a basic G.704 E1 signal. The signaling multiframe alignment structure and the CRC multiframe structure may be optionally inserted. Framing can be optionally disabled. Transmission of the 4-bit Sa codewords defined in ITU-T G.704 and ETSI 300233 is supported. PRBS generation or detection is supported on a framed and unframed E1 basis. The TEMUX can generate a low jitter transmit clock from a variety of clock references, and also provides jitter attenuation in the receive path. Two low jitter
PROPRIETARY AND CONFIDENTIAL
27
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
recovered T1 clocks can be routed outside the TEMUX for network timing applications. Serial PCM interfaces to each T1 framer allow 1.544 Mbit/s ingress/egress system interfaces to be directly supported. Tolerance of gapped clocks allows other backplane rates to be supported with a minimum of external logic. In synchronous backplane systems 8Mb/s H-MVIP interfaces are provided for access to 672 DS0 channels, channel associated signaling (CAS) for all 672 DS0 channels and common channel signaling (CCS) for all 28 T1s. The DS0 data channel H-MVIP and CAS H-MVIP access is multiplexed with the serial PCM interface pins. The CCS signaling H-MVIP interface is independent of the DS0 channel and CAS H-MVIP access. The use of any of the H-MVIP interfaces requires that common clocks and frame pulse be used along with T1 slip buffers. A Scaleable Bandwidth Interconnect (SBI) high density byte serial system interface provides higher levels of integration and dense interconnect. The SBI bus interconnects up to 84 T1s or 63 E1 both synchronously or asynchronously. The SBI allows transmit timing to be mastered by either the TEMUX or link layer device connected to the SBI bus. This interconnect allows up to 3 TEMUXs to be connected in parallel to provide the full complement of 84 T1s or 63 E1s of traffic. In addition to framed T1s and E1s the TEMUX can transport unframed T1 or E1 links and framed or unframed DS3 links over the SBI bus. When configured as a DS3 multiplexer/demultiplexer or DS3 framer, the TEMUX accepts and outputs either or both digital B3ZS-encoded bipolar and unipolar signals compatible with M23 and C-bit parity applications. In the DS3 receive direction, the TEMUX frames to DS3 signals with a maximum average reframe time of 1.5 ms in the presence of 10-3 bit error rate and detects line code violations, loss of signal, framing bit errors, parity errors, C-bit parity errors, far end block errors, AIS, far end receive failure and idle code. The DS3 framer is an off-line framer, indicating both out of frame (OOF) and change of frame alignment (COFA) events. The error events (C-BIT, FEBE, etc.) are still indicated while the framer is OOF, based on the previous frame alignment. When in C-bit parity mode, the Path Maintenance Data Link and the Far End Alarm and Control (FEAC) channels are extracted. HDLC receivers are provided for Path Maintenance Data Link support. In addition, valid bit-oriented codes in the FEAC channels are detected and are available through the microprocessor port. Error event accumulation is also provided by the TEMUX. Framing bit errors, line code violations, excessive zeros occurrences, parity errors, C-bit parity errors, and far end block errors are accumulated. Error accumulation continues even while the off-line framers are indicating OOF. The counters are intended to be polled once per second, and are sized so as not to saturate at a 10-3 bit error
PROPRIETARY AND CONFIDENTIAL
28
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
rate. Transfer of count values to holding registers is initiated through the microprocessor interface. In the DS3 transmit direction, the TEMUX inserts DS3 framing, X and P bits. When enabled for C-bit parity operation, bit-oriented code transmitters and HDLC transmitters are provided for insertion of the FEAC channels and the Path Maintenance Data Links into the appropriate overhead bits. Alarm Indication Signals, Far End Receive Failure and idle signal can be inserted using either internal registers or can be configured for automatic insertion upon received errors. When M23 operation is selected, the C-bit Parity ID bit (the first C-bit of the first M sub-frame) is forced to toggle so that downstream equipment will not confuse an M23-formatted stream with stuck-at-1 C-bits for C-bit Parity application. Transmit timing is from an external reference or from the receive direction clock. The TEMUX also supports diagnostic options which allow it to insert, when appropriate for the transmit framing format, parity or path parity errors, F-bit framing errors, M-bit framing errors, invalid X or P-bits, line code violations, all-zeros, AIS, Remote Alarm Indications, and Remote End Alarms. A Pseudo Random Binary Sequence (PRBS) can be inserted into a DS3 payload and checked in the receive DS3 payload for bit errors. A fixed 100100... pattern is available for insertion directly into the B3ZS encoder for proper pulse mask shape verification. When configured in DS3 multiplexer mode, seven 6312 kbit/s data streams are demultiplexed and multiplexed into and out of the DS3 signal. Bit stuffing and rate adaptation is performed. The C-bits are set appropriately, with the option of inserting DS2 loopback requests. Interrupts can be generated upon detection of loopback requests in the received DS3. AIS may be inserted in the any of the 6312 kbit/s tributaries in both the multiplex and demultiplex directions. C-bit parity is supported by sourcing a 6.3062723 MHz clock, which corresponds to a stuffing ratio of 100%. Framing to the demultiplexed 6312 kbit/s data streams supports DS2 (ANSI TI.107) frame formats. The maximum average reframe time is 7ms for DS2. Far end receive failure is detected and M-bit and F-bit errors are accumulated. The DS2 framer is an off-line framer, indicating both OOF and COFA events. Error events (FERF, MERR, FERR, PERR, RAI, framing word errors) are still indicated while the DS2 framer is indicating OOF, based on the previous alignment. Each of the seven 6312 kbit/s multiplexers may be independently configured to multiplex and demultiplex four 1544 kbit/s DS1s into and out of a DS2 formatted signal. Tributary frequency deviations are accommodated using internal FIFOs and bit stuffing. The C-bits are set appropriately, with the option of inserting DS1 loopback requests. Interrupts can be generated upon detection of loopback
PROPRIETARY AND CONFIDENTIAL
29
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
requests in the received DS2. AIS may be inserted in any of the low speed tributaries in both multiplex and demultiplex directions. When configured as a DS3 framer the unchannelized payload of the DS3 link is available to an external device. The SONET/SDH line side interface provides STS-1 SPE synchronous payload envelope processing and generation, TUG3 tributary unit group processing and generation within a VC4 virtual container and VC3 virtual container processing and generation. The payload processor aligns and monitors the performance of SONET virtual tributaries (VTs) or SDH tributary units (TUs). Maintenance functions per tributary include detection of loss of pointer, AIS alarm, tributary path signal label mismatch and tributary path signal label unstable alarms. Optionally interrupts can be generated due to the assertion and removal of any of the above alarms. Counts are accumulated for tributary path BIP-2 errors on a block or bit basis and for FEBE indications. The synchronous payload envelope generator generates all tributary pointers and calculates and inserts tributary path BIP-2. The generator also inserts FEBE, RDI and enhanced RDI in the V5 byte. Software can force AIS insertion on a per tributary basis. A SONET/SDH mapper maps and demaps up to 28 T1s, 21 E1s or a single DS3 into a STS-1 SPE, TUG3 or VC3 through an elastic store. The fixed stuff (R) bits are all set to zeros or ones under microprocessor control. The bit asynchronous demapper performs majority vote C-bit decoding to detect stuff requests for T1, E1 and DS3 asynchronous mappings. The VT1.5/VT2/TU-11/TU-12 mapper uses an elastic store and a jitter attenuator capability to minimize jitter introduced via bit stuffing. The TEMUX is configured, controlled and monitored via a generic 8-bit microprocessor bus through which all internal registers are accessed. All sources of interrupts can be masked and acknowledged through the microprocessor interface.
PROPRIETARY AND CONFIDENTIAL
30
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
7
PIN DIAGRAM The TEMUX is currently planned to be packaged in a 324-pin PBGA package having a body size of 23mm by 23mm and a ball pitch of 1.0 mm. The center 36 balls are not used as signal I/Os and are thermal balls. Pin names and locations are defined in the Pin Description Table in section 8. Mechanical information for this package is in the section 19. Figure 7 - Pin Diagram
9 8 7 6 5 4 3 2 1
22 21 20 19 18 17 16 15 14 13 12 11 10 A B C D E F G H J K L M N P R T U V W Y AA AB 22 21 20 19 18 17 16 15 14 13 12 11 10
VSS VSS VSS VSS VSS VSS VSS VSS VSS VSS VSS VSS VSS VSS VSS VSS VSS VSS VSS VSS VSS VSS VSS VSS VSS VSS VSS VSS VSS VSS
324 PBGA
VSS VSS VSS VSS VSS VSS
Bottom View
9
8
7
6
5
4
3
2
1
PROPRIETARY AND CONFIDENTIAL
31
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
8
PIN DESCRIPTION Type Pin Function No.
Pin Name
DS3 Line Side Interface RCLK Input W5 Receive Input Clock (RCLK). RCLK provides the receive direction timing. RCLK is a DS3, nominally a 44.736 MHz, 50% duty cycle clock input. Positive Input Pulse (RPOS). RPOS represents the positive pulses received on the B3ZS-encoded DS3 when dual rail input format is selected. Receive Data Input (RDAT). RDAT represents the NRZ (unipolar) DS3 input data stream when single rail input format is selected. RPOS and RDAT are sampled on the rising edge of RCLK by default and may be enabled to be sampled on the falling edge of RCLK by setting the RFALL bit in the DS3 Master Receive Line Options register. RNEG/RLCV Input AB6 Negative Input Pulse (RNEG). RNEG represents the negative pulses received on the B3ZS-encoded DS3 when dual rail input format is selected. Line code violation (RLCV). RLCV represents receive line code violations when single rail input format is selected. RNEG and RLCV are sampled on the rising edge of RCLK by default and may be enabled to be sampled on the falling edge of RCLK by setting the RFALL bit in the DS3 Master Receive Line Options register. TCLK Output AA7 Transmit Clock (TCLK). TCLK provides timing for circuitry downstream of the DS3 transmitter of the TEMUX. TCLK is nominally a 44.736 MHz, 50% duty cycle clock.
RPOS/RDAT
Input
Y7
PROPRIETARY AND CONFIDENTIAL
32
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Pin Name TPOS/TDAT
Type
Pin Function No.
Output AB7 Transmit Positive Pulse (TPOS). TPOS represents the positive pulses transmitted on the B3ZS-encoded DS3 line when dual-rail output format is selected. Transmit Data Output (TDAT). TDAT represents the NRZ (unipolar) DS3 output data stream when single rail output format is selected. TPOS and TDAT are updated on the falling edge of TCLK by default but may be enabled to be updated on the rising edge of TCLK by setting the TRISE bit in the DS3 Master Transmit Line Options register. TPOS and TDAT are updated on TICLK rather than TCLK when the TICLK bit in the DS3 Master Transmit Line Options register is set.
TNEG/TMFP
Output W6
Transmit Negative Pulse (TNEG). TNEG represents the negative pulses transmitted on the B3ZS-encoded DS3 line when dual-rail output format is selected. Transmit Multiframe Pulse (TMFP). This signal marks the transmit M-frame alignment when configured for single rail operation. TMFP indicates the position of overhead bits in the transmit transmission system stream, TDAT. TMFP is high during the first bit (X1) of the multiframe. TNEG and TMFP are updated on the falling edge of TCLK by default but may be enabled to be updated on the rising edge of TCLK by setting the TRISE bit in the DS3 Master Transmit Line Options register. TNEG and TMFP are updated on TICLK rather than TCLK when the TICLK bit in the DS3 Master Transmit Line Options register is set.
TICLK
Input
AA6 Transmit input clock (TICLK). TICLK provides the transmit direction timing. TICLK is nominally a 44.736 MHz, 50% duty cycle clock. This clock is only required when using the DS3 transmitter, either with the DS3 line side interface or the DS3 mapper. When not used this clock input should be connected to ground.
PROPRIETARY AND CONFIDENTIAL
33
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Pin Name XCLK/VCLK
Type Input
Pin Function No. E20 Crystal Clock Input (XCLK). This 24 times T1 or E1 clock provides timing for many of the T1 and E1 portions of TEMUX. XCLK is nominally a 37.056 MHz 32ppm, 50% duty cycle clock when configured for T1 modes and is nominally a 49.152 MHz 32ppm, 50% duty cycle clock when configured for E1 modes. This clock is required for all operating modes of the TEMUX. Test Vector Clock (VCLK). This signal is used during production testing.
PROPRIETARY AND CONFIDENTIAL
34
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Pin Name
Type
Pin Function No.
DS3 System Side Interface RGAPCLK/RSCLK Output Y3 Framer Recovered Gapped Clock (RGAPCLK). RGAPCLK is valid when the TEMUX is configured as a DS3 framer by setting the OPMODE[1:0] bits in the Global Configuration register and the RXGAPEN bit in the DS3 Master Unchannelized Interface Options register. RGAPCLK is the recovered clock and timing reference for RDATO. RGAPCLK is held either high or low during bit positions which correspond to overhead. Framer Recovered Clock (RSCLK). RSCLK is valid when the TEMUX is configured as a DS3 framer by setting the OPMODE[1:0] bits in the Global Configuration register. RSCLK is the recovered clock and timing reference for RDATO, RFPO/RMFPO, and ROVRHD. This signal shares a signal pin with ICLK[1]. When enabled for unchannelized DS3 operation this signal will be RGAPCLK/RSCLK, otherwise it will be ICLK[1]. RDATO Output AA5 Framer Receive Data (RDATO). RDATO is valid when the TEMUX is configured as a DS3 framer by setting the OPMODE[1:0] bits in the Global Configuration register. RDATO is the received data aligned to RFPO/RMFPO and ROVRHD. RDATO is updated on either the falling or rising edge of RGAPCLK or RSCLK, depending on the value of the RSCLKR bit in the DS3 Master Unchannelized Interface Options register. By default RDATO will be updated on the falling edge of RGAPCLK or RSCLK. This signal shares a signal pin with ID[1] and MVID[1]. This signal will be RDATO only when enabled for unchannelized DS3 operation.
PROPRIETARY AND CONFIDENTIAL
35
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Pin Name RFPO/RMFPO
Type
Pin Function No.
Output AB5 Framer Receive Frame Pulse/Multi-frame Pulse (RFPO/RMFPO). RFPO/RMFPO is valid when the TEMUX is configured to be in framer only mode by setting the OPMODE[1:0] bits in the Global Configuration register. RFPO is aligned to RDATO and indicates the position of the first bit in each DS3 M-subframe. RMFPO is aligned to RDATO and indicates the position of the first bit in each DS3 M-frame. This is selected by setting the RXMFPO bit in the Master Framer Configuration Registers. RFPO/RMFPO is updated on either the falling or rising edge of RSCLK depending on the setting of the RSCLKR bit in the DS3 Master Unchannelized Interface Options register. This signal shares a signal pin with IFP[1]. When enabled for unchannelized DS3 operation this signal will be RFPO/RMFPO, otherwise it will be IFP[1].
ROVRHD
Output Y6
Framer Receive Overhead (ROVRHD). ROVRHD is valid when the TEMUX is configured as a DS3 framer by setting the OPMODE[1:0] bits in the Global Configuration register. ROVRHD will be high whenever the data on RDATO corresponds to an overhead bit position. ROVRHD is updated on the either the falling or rising edge of RSCLK depending on the setting of the RSCLKR bit in the DS3 Master Unchannelized Interface Options register. This signal shares a signal pin with ID[2] and CASID[1]. This signal will be ROVRHD only when enabled for unchannelized DS3 operation.
PROPRIETARY AND CONFIDENTIAL
36
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Pin Name TFPO/TMFPO/ TGAPCLK
Type
Pin Function No.
Output AB3 Framer Transmit Frame Pulse/Multi-frame Pulse Reference (TFPO/TMFPO). TFPO/TMFPO is valid when the TEMUX is configured as a DS3 framer by setting the OPMODE[1:0] bits in the Global Configuration register and setting the TXGAPEN bit to 0 in the DS3 Master Unchannelized Interface Options register. TFPO pulses high for 1 out of every 85 clock cycles, giving a reference M-subframe indication. TMFPO pulses high for 1 out of every 4760 clock cycles, giving a reference M-frame indication. TFPO/TMFPO is updated on the falling edge of TICLK. TFPO/TMFPO can be configured to be updated on the rising edge of TICLK by setting the TDATIFALL bit to 1in the DS3 Master Unchannelized Interface Options register.. Framer Gapped Transmit Clock (TGAPCLK). TGAPCLK is valid when the TEMUX is configured as a DS3 framer by setting the OPMODE[1:0] bits in the Global Configuration register and setting the TXGAPEN bit to 1 in the DS3 Master Unchannelized Interface Options register. TGAPCLK is derived from the transmit reference clock TICLK or from the receive clock if loop-timed. The overhead bit (gapped) positions are generated internal to the device. TGAPCLK is held high during the overhead bit positions. This clock is useful for interfacing to devices which source payload data only. TGAPCLK is used to sample TDATI and TFPI/TMFPI when TXGAPEN is set to 1. This signal shares a signal pin with ECLK[1]. When enabled for unchannelized DS3 operation this signal will be TFPO/TMFPO/TGAPCLK, otherwise it will be ECLK[1].
PROPRIETARY AND CONFIDENTIAL
37
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Pin Name TDATI
Type Input
Pin Function No. AB4 Framer Transmit Data (TDATI). TDATI contains the serial data to be transmitted when the TEMUX is configured as a DS3 framer by setting the OPMODE[1:0] bits in the Global Configuration register. TDATI is sampled on the rising edge of TICLK if the TXGAPEN bit in the DS3 Master Unchannelized Interface Options register is logic 0. If TXGAPEN is logic 1, then TDATI is sampled on the rising edge of TGAPCLK. TDATI can be configured to be sampled on the falling edge of TICLK or TGAPCLK by setting the TDATIFALL bit in the DS3 Master Unchannelized Interface Options register. This signal shares a signal pin with ED[1] and MVED[1]. This signal will be TDATI only when enabled for unchannelized DS3 operation.
TFPI/TMFPI
Input
AA3 Framer Transmit Frame Pulse/Multiframe Pulse (TFPI/TMFPI). TFPI/TMFPI is valid when the TEMUX is configured as a DS3 framer by setting the OPMODE[1:0] bits in the Global Configuration register. TFPI indicates the position of all overhead bits in each DS3 M-subframe. TFPI is not required to pulse at every frame boundary. TMFPI indicates the position of the first bit in each DS3 M-frame. TMFPI is not required to pulse at every multiframe boundary. TFPI/TMFPI is sampled on the rising edge of TICLK if the TXGAPEN bit in the DS3 Master Unchannelized Interface Options register is logic 0. If TXGAPEN is logic 1, then TFPI/TMFPI is sampled on the rising edge of TGAPCLK. TFPI/TMFPI can be configured to be sampled on the falling edge of TICLK or TGAPCLK by setting the TDATIFALL bit to 1in the DS3 Master Unchannelized Interface Options register. This signal shares a signal pin with ED[2] and CASED[1]. This signal will be TFPI/TMFPI only when enabled for unchannelized DS3 operation.
PROPRIETARY AND CONFIDENTIAL
38
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Pin Name
Type
Pin Function No.
T1 and E1 System Side Serial Clock and Data Interface ICLK[1]/ISIG[1] Output Y3 Ingress Clocks (ICLK[1:28]). The Ingress Clocks are AB2 active when the external signaling interface is disabled. ICLK[2]/ISIG[2] ICLK[3]/ISIG[3] AB20 Each ingress clock is optionally a smoothed (jitter AB21 attenuated) version of the associated receive clock ICLK[4]/ISIG[4] ICLK[5]/ISIG[5] W22 from either the SONET/SDH mapper or the DS3 Y20 multiplexer. When the Clock Master: NxChannel mode ICLK[6]/ISIG[6] ICLK[7]/ISIG[7] H22 is active, ICLK[x] is a gapped version of the smoothed F19 receive clock. When Clock Master: Full T1/E1 mode is ICLK[8]/ISIG[8] W3 active, IFP[x] and ID[x] are updated on the active edge ICLK[9]/ISIG[9] AA1 of ICLK[x]. When the Clock Master: NxDS0 mode is ICLK[10]/ISIG[10] H3 active, ID[x] is updated on the active edge of ICLK[x]. ICLK[11]/ISIG[11] H1 ICLK[12]/ISIG[12] L22 ICLK[13]/ISIG[13] K19 Ingress Signaling (ISIG[1:28]). When the Clock ICLK[14]/ISIG[14] F22 Slave: External Signaling mode is enabled, each ICLK[15]/ISIG[15] G20 ISIG[x] contains the extracted signaling bits for each ICLK[16]/ISIG[16] T3 channel in the frame, repeated for the entire ICLK[17]/ISIG[17] U1 superframe. Each channel's signaling bits are valid in ICLK[18]/ISIG[18] D1 bit locations 5,6,7,8 of the channel and are channelICLK[19]/ISIG[19] C1 aligned with the ID[x] data stream. ISIG[x] is updated ICLK[20]/ISIG[20] H19 on the active edge of the common ingress clock, ICLK[21]/ISIG[21] G19 CICLK. ICLK[22]/ISIG[22] E19 ICLK[23]/ISIG[23] F21 ICLK[24]/ISIG[24] K3 In E1 mode only ICLK[1:21] and ISIG[1:21] are used. ICLK[25]/ISIG[25] J4 ICLK[26]/ISIG[26] ICLK[1]/ISIG[1] shares a pin with the DS3 system E3 interface signal RGAPCLK/RSCLK. ICLK[27]/ISIG[27] D2 ICLK[28]/ISIG[28]
PROPRIETARY AND CONFIDENTIAL
39
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Pin Name IFP[1] IFP[2] IFP[3] IFP[4] IFP[5] IFP[6] IFP[7] IFP[8] IFP[9] IFP[10] IFP[11] IFP[12] IFP[13] IFP[14] IFP[15] IFP[16] IFP[17] IFP[18] IFP[19] IFP[20] IFP[21] IFP[22] IFP[23] IFP[24] IFP[25] IFP[26] IFP[27] IFP[28]
Type
Pin Function No.
Output AB5 Ingress Frame Pulse (IFP[1:28]). The IFP[x] outputs V3 are intended as timing references. W20 IFP[x] indicates the frame alignment or the superframe AA22 alignment of the ingress stream, ID[x]. Y21 W21 When Clock Master: Full T1/E1 mode is active, IFP[x] K22 is updated on the active edge of the associated K21 ICLK[x]. When Clock Master: NxDS0 mode is active, Y1 ICLK[x] is gapped during the pulse on IFP[x]. When W1 the Clock Slave ingress modes are active, IFP[x] is F4 updated on the active edge of CICLK. I the Clear G1 Channel modes IFP[x] is not used. V20 In E1 mode only IFP[1:21] is used. Y22 K20 IFP[1] shares a pin with the DS3 system interface J19 signal RFPO/RMFPO. IFP[20,27,28] shares pins with W4 the SBI interface signals SDDP, SDPL, SDV5. V1 E1 D9 U19 R22 J22 J20 K1 K2 D8 A9
PROPRIETARY AND CONFIDENTIAL
40
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Pin Name ID[1] ID[2] ID[3] ID[4] ID[5] ID[6] ID[7] ID[8] ID[9] ID[10] ID[11] ID[12] ID[13] ID[14] ID[15] ID[16] ID[17] ID[18] ID[19] ID[20] ID[21] ID[22] ID[23] ID[24] ID[25] ID[26] ID[27] ID[28]
Type
Pin Function No.
Output AA5 Ingress Data (ID[1:28]). Each ID[x] signal contains Y6 the recovered data stream which may have been AA20 passed through the elastic store. T19 When the Clock Slave ingress modes are active, the R19 ID[x] stream has passed through the elastic store and P20 is aligned to the common ingress timing. In this mode G22 ID[x] is updated on the active edge of CICLK. G21 Y2 When the Clock Master ingress modes are active, ID[x] W2 is aligned to the receive line timing and is updated on G4 the active edge of the associated ICLK[x]. H2 In E1 mode only ID[1:21] are used. P21 P22 ID[1,5,9,13,17,21,25] share pins with the H-MVIP data A12 signals MVID[1:7]. ID[2,6,10,14,18,22,26] share pins D12 with the H-MVIP CAS signals CASID[1:7]. ID[1] shares U2 a pin with the DS3 system interface signal RDATO. V4 ID[2] shares a pin with the DS3 system interface signal D11 ROVRHD. ID[15,16,19,20,23,24,27,28] shares pins A11 with the SBI interface bus SDDATA[7:0]. M19 L19 D10 A10 J1 H4 B10 C10
PROPRIETARY AND CONFIDENTIAL
41
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Pin Name CICLK
Type Input
Pin Function No. N1 Common Ingress Clock (CICLK). CICLK is either a 1.544MHz clock in T1 mode or a 2.048MHz clock in T1 or E1 modes, with optional gapping for adaptation to non-uniform backplane data streams. CICLK is common to all 28 T1 or 21 E1 framers. CIFP is sampled on the active edge of CICLK. When the Clock Slave ingress modes are active, ID[x], ISIG[x], and IFP[x] are updated on the active edge of CICLK. CICLK is a nominal 1.544 or 2.048 MHz clock +/50ppm with a 50% duty cycle. This signal shares a pin with the H-MVIP signal CMVFPC. By default this input is CICLK.
CIFP
Input
P4
Common Ingress Frame Pulse (CIFP). When the elastic store is enabled (Clock Slave mode is active on the ingress side), CIFP is used to frame align the ingress data to the system frame alignment. CIFP is common to all 28 T1 or 21 E1 framers. When frame alignment is required, a pulse at least 1 CICLK cycle wide must be provided on CIFP a maximum of once every frame (nominally 193 or 256 bit times). CIFP is sampled on the active edge of CICLK as selected by the CIFE bit in the Master Common Ingress Serial and H-MVIP Interface Configuration register.
PROPRIETARY AND CONFIDENTIAL
42
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Pin Name CTCLK
Type Input
Pin Function No. M3 Common Transmit Clock (CTCLK). This input signal is used as a reference transmit tributary clock which can be used in egress Clock Master modes. Depending on the configuration of the TEMUX, CTCLK may be a line rate clock (so the transmit clock is generated directly from CTCLK, or from CTCLK after jitter attenuation), or a multiple of 8kHz (Nx8khz, where 1N256) so long as CTCLK is jitter-free when divided down to 8kHz (in which case the transmit clock is derived by the DJAT PLL using CTCLK as a reference). The TEMUX may be configured to ignore the CTCLK input and utilize CECLK or one of the recovered Ingress clocks instead, RECVCLK1 and RECVCLK2. Receive tributary clock[x] is automatically substituted for CTCLK if line loopback is enabled.
CECLK
Input
N4
Common Egress Clock (CECLK). The common egress clock is used to time the egress interface when Clock Slave mode is enabled in the egress side. CECLK may be a 1.544MHz or 2.048MHz clock with optional gapping for adaptation from non-uniform system clocks. When the Clock Slave: EFP Enabled mode is active, CEFP and ED[x] are sampled on the active edge of CECLK, and EFP[x] is updated on the active edge of CECLK. When the Clock Slave: External Signaling mode is active, CEFP, ESIG[x] and ED[x] are sampled on the active edge of CECLK. CECLK is a nominal 1.544 or 2.048 MHz clock +/50ppm with a 50% duty cycle. This signal shares a pin with the H-MVIP signal CMV8MCLK. By default this input is CECLK.
PROPRIETARY AND CONFIDENTIAL
43
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Pin Name CEFP
Type Input
Pin Function No. M2 Common Egress Frame Pulse (CEFP). CEFP may be used to frame align the framers to the system backplane. If frame alignment only is required, a pulse at least 1 CECLK cycle wide must be provided on CEFP every 193 bit times for T1 mode or every 256 bit times for T1 and E1 modes (T1 mode using 2.048MHz clock). If superframe alignment is required, transmit superframe alignment must be enabled, and a pulse at least 1 CECLK cycle wide must be provided on CEFP every 12 or 24 frame times for T1 mode, on the first Fbit of the multiframe. CEFP is sampled on the active edge of CECLK as selected by the CEFE bit in the Master Common Egress Serial and H-MVIP Interface Configuration register. CEFP has no effect in the Clock Master egress modes. This signal shares a pin with the H-MVIP signal CMVFPB. By default this input is CEFP.
PROPRIETARY AND CONFIDENTIAL
44
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Pin Name ED[1] ED[2] ED[3] ED[4] ED[5] ED[6] ED[7] ED[8] ED[9] ED[10] ED[11] ED[12] ED[13] ED[14] ED[15] ED[16] ED[17] ED[18] ED[19] ED[20] ED[21] ED[22] ED[23] ED[24] ED[25] ED[26] ED[27] ED[28]
Type Input
Pin Function No. AB4 AA3 P19 N20 N21 N22 A7 A2 T2 R4 A3 B4 N19 M22 D6 C7 P2 M1 D4 B6 C20 E22 A5 B5 L1 L2 A4 C5 Egress Data (ED[1:28]). The egress data streams to be transmitted are input on these pins. When the Clock Master modes are active, ED[x] is sampled on the active edge of ECLK[x], except for Clock Master: Serial Data and H-MVIP CCS, when ED[x] is sampled on the active edge of ICLK[x]. When the Clock Slave egress modes are active, ED[x] is sampled on the active edge of CECLK, except for Clock Slave: Clear channel mode when ED[x] is sampled on the active edge of ECLK[x]. In E1 mode only ED[1:21] are used. ED[1,5,9,13,17,21,25] share pins with the H-MVIP data signals MVED[1:7]. ED[2,6,10,14,18,22,26] share pins with the H-MVIP CAS signals CASED[1:7]. ED[1] shares a pin with the DS3 system interface signal TDATI. ED[2] shares a pin with the DS3 system interface signal TFPI/TMFPI. ED[7,8,11,12,15,16,19,20,23,24,27,28] shares pins with the SBI interface add bus signals.
PROPRIETARY AND CONFIDENTIAL
45
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Pin Name
Type
Pin Function No. AB3 Y4 Y19 AA21 AB22 V22 T21 T22 AB1 T1 G2 G3 U21 V19 D21 C21 U4 R1 D3 F1 T20 U22 B22 D20 L3 K4 E4 F2 Egress Clock (ECLK[1:28]). When the Clock Master mode is active, ECLK[x] is an output and is used to sample the associated egress data, ED[x]. ECLK[x] is a version of the transmit clock[x] which is generated from the receive clock or the common transmit clock, CTCLK. When in Clock Master: NxChannel mode, ECLK[x] is gapped during the framing bit position and optionally for between 1 and 23 DS0 channels or 1 and 32 channel timeslots in the associated ED[x] stream. When Clock Master: Clear Channel is active ECLK[x] is not gapped. When in Clock Slave: Clear Channel mode this input is an input and is used to sampled ED[x]. ED[x] is sampled on the active edge of the associated ECLK[x]. Egress Frame Pulse (EFP[1:28]). When the Clock Slave: EFP Enabled mode is active, the EFP[1:28] outputs indicate the frame alignment or the superframe alignment of each of the 28 framers. EFP[x] is updated on the active edge of CECLK. Egress Signaling (ESIG[1:28]). When the Clock Slave: External Signaling mode is active, the ESIG[1:28] input carries the signaling bits for each channel in the transmit data frame, repeated for the entire superfram'. Each channel's signaling bits are in bit locations 5,6,7,8 of the channel and are frame-aligned by the common egress frame pulse, CEFP. ESIG[x] is sampled on the active edge of CECLK. ECLK[1]/EFP[1]/ESIG[1] shares a pin with the DS3 system interface output signal TFPO/TMFPO/TGAPCLK.
ECLK[1]/EFP[1]/ESIG[1] I/O ECLK[2]/EFP[2]/ESIG[2] ECLK[3]/EFP[3]/ESIG[3] ECLK[4]/EFP[4]/ESIG[4] ECLK[5]/EFP[5]/ESIG[5] ECLK[6]/EFP[6]/ESIG[6] ECLK[7]/EFP[7]/ESIG[7] ECLK[8]/EFP[8]/ESIG[8] ECLK[9]/EFP[9]/ESIG[9] ECLK[10]/EFP[10]/ESIG[10] ECLK[11]/EFP[11]/ESIG[11] ECLK[12]/EFP[12]/ESIG[12] ECLK[13]/EFP[13]/ESIG[13] ECLK[14]/EFP[14]/ESIG[14] ECLK[15]/EFP[15]/ESIG[15] ECLK[16]/EFP[16]/ESIG[16] ECLK[17]/EFP[17]/ESIG[17] ECLK[18]/EFP[18]/ESIG[18] ECLK[19]/EFP[19]/ESIG[19] ECLK[20]/EFP[20]/ESIG[20] ECLK[21]/EFP[21]/ESIG[21] ECLK[22]/EFP[22]/ESIG[22] ECLK[23]/EFP[23]/ESIG[23] ECLK[24]/EFP[24]/ESIG[24] ECLK[25]/EFP[25]/ESIG[25] ECLK[26]/EFP[26]/ESIG[26] ECLK[27]/EFP[27]/ESIG[27] ECLK[28]/EFP[28]/ESIG[28]
PROPRIETARY AND CONFIDENTIAL
46
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Pin Name
Type
Pin Function No.
MVIP System Side Interfaces CMV8MCLK Input N4 Common 8M MVIP Clock (CMV8MCLK). The common 8.192 Mbps H-MVIP data provides the data clock for receive and transmit links configured for operation in 8.192 Mbps H-MVIP mode. CMV8MCLK is used to sample data on MVID[1:7], MVED[1:7], CASID[1:7], CASED[1:7], CCSID and CCSED. CMV8MCLK is nominally a 50% duty cycle clock with a frequency of 16.384MHz. The H-MVIP interfaces are enabled via the SYSOPT[2:0] bits in the Global Configuration register. This signal shares a pin with CECLK. By default this input is CECLK. CMVFPC Input N1 Common MVIP Frame Pulse Clock (CMVFPC). The common 8.192 Mbps H-MVIP frame pulse clock provides the frame pulse clock for receive and transmit links configured for operation in 8.192 Mbps H-MVIP mode. CMVFPC is used to sample CMVFPB. CMVFPC is nominally a 50% duty cycle clock with a frequency of 4.096 MHz. The falling edge of CMVFPC must be aligned with the falling edge of CMV8MCLK with no more than 10ns skew. The H-MVIP interfaces are enabled via the SYSOPT[2:0] bits in the Global Configuration register. This signal shares a pin with CICLK. By default this input is CICLK.
PROPRIETARY AND CONFIDENTIAL
47
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Pin Name CMVFPB
Type Input
Pin Function No. M2 Common MVIP Frame Pulse (CMVFPB). The active low common frame pulse for 8.192 Mbps H-MVIP signals references the beginning of each frame for links operating in 8.192Mbps H-MVIP mode. The H-MVIP interfaces are enabled via the SYSOPT[2:0] bits in the Global Configuration register. The CMVFPB frame pulse occurs every 125us for a and is sampled on the falling edge of CMVFPC. This signal shares a pin with CEFP. By default this input is CEFP.
MVID[1] MVID[2] MVID[3] MVID[4] MVID[5] MVID[6] MVID[7]
Output AA5 R19 Y2 P21 U2 M19 J1
H-MVIP Ingress Data (MVID[1:7]). MVID[x] carries the recovered T1 or E1 channels which have passed through the elastic store. Each MVID[x] signal carries the channels of four complete T1s or E1s. MVID[x] carries the T1 or E1 data equivalent to ID[(4x-3):(4x)]. MVID[x] is aligned to the common H-MVIP 16.384Mb/s clock, CMV8MCLK, frame pulse clock, CMVFPC, and frame pulse, CMVFPB. MVID[x] is updated on every second rising or falling edge of the common H-MVIP 16.384Mb /s clock, CMV8MCLK, as fixed by the common MVIP frame pulse clock, CMVFPC. The updating edge of CMV8MCLK is selected via the CMVIDE bit in the Master Common Ingress Serial and H-MVIP Interface Configuration register. In E1 mode only MVID[1:6] are used. MVID[1:7] shares the same pins as ID[1,5,9,13,17,21,25].
PROPRIETARY AND CONFIDENTIAL
48
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Pin Name CASID[1] CASID[2] CASID[3] CASID[4] CASID[5] CASID[6] CASID[7]
Type
Pin Function No. Channel Associated Signaling Ingress Data (CASID[1:7]). CASID[x] carries the channel associated signaling stream extracted from all the T1 or E1 channels. Each CASID[x] signal carries CAS for four complete T1s or E1s. CASID[x] carries the corresponding CAS values of the channel carried in MVID[x]. CASID[x] is aligned to the common H-MVIP 16.384Mb/s clock, CMV8MCLK, frame pulse clock, CMVFPC, and frame pulse, CMVFPB. CASID[x] is updated on every second rising or falling edge of CMV8MCLK as fixed by the common MVIP frame pulse clock, CMVFPC. The updating edge of CMV8MCLK is selected via the CMVIDE bit in the Master Common Ingress Serial and H-MVIP Interface Configuration register. CASID[1:7] shares the same pins as ID[2,6,10,14,18,22,26].
Output Y6 P20 W2 P22 V4 L19 H4
CCSID
Output T4
Common Channel Signaling Ingress Data (CCSID). In T1 mode CCSID carries the 28 common channel signaling channels extracted from each of the 28 T1s. In E1 mode CCSID carries up to 3 timeslots (15,16, 31) from each of the 21 E1s. CCSID is formatted according to the MVIP standard. CCSID is aligned to the common MVIP 16.384Mb/s clock, CMV8MCLK, frame pulse clock, CMVFPC, and frame pulse, CMVFPB. CCSID is updated on every second rising or falling edge of CMV8MCLK as fixed by the common MVIP frame pulse clock, CMVFPC. The updating edge of CMV8MCLK is selected via the CMVIDE bit in the Master Common Ingress Serial and H-MVIP Interface Configuration register.
PROPRIETARY AND CONFIDENTIAL
49
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Pin Name MVED[1] MVED[2] MVED[3] MVED[4] MVED[5] MVED[6] MVED[7]
Type Input
Pin Function No. AB4 N21 T2 N19 P2 C20 L1 MVIP Egress Data (MVED[1:7]). The egress data streams to be transmitted are input on these pins. Each MVED[x] signal carries the channels of four complete T1s formatted according to the MVIP standard. MVED[x] carries the egress data equivalent to ED[(4x-3):(4x)]. MVID[x] is aligned to the common MVIP 16.384Mb/s clock, CMV8MCLK, frame pulse clock, CMVFPC, and frame pulse, CMVFPB. MVID[x] is sampled on every second rising or falling edge of CMV8MCLK as fixed by the common MVIP frame pulse clock, CMVFPC. The sampling edge of CMV8MCLK is selected via the CMVEDE bit in the Master Common Ingress Serial and H-MVIP Interface Configuration register. In E1 mode only MVED[1:6] are used. MVED[1:7] shares the same pins as ED[1,5,9,13,17,21,25].
CASED[1] CASED[2] CASED[3] CASED[4] CASED[5] CASED[6] CASED[7]
Input
AA3 N22 R4 M22 M1 E22 L2
Channel Associated Signaling Egress Data (CASED[1:7]). CASED[x] carries the channel associated signaling stream to be transmitted in the T1 DS0s or E1 timeslots. Each CASED[x] signal carries CAS for four complete T1s or E1s formatted according to the MVIP standard. CASED[x] carries the corresponding CAS values of the channel data carried in MVED[x]. CASED[x] is aligned to the common MVIP 16.384Mb/s clock, CMV8MCLK, frame pulse clock, CMVFPC, and frame pulse, CMVFPB. CASED[x] is sampled on every second rising or falling edge of CMV8MCLK as fixed by the common MVIP frame pulse clock, CMVFPC. The sampling edge of CMV8MCLK is selected via the CMVEDE bit in the Master Common Ingress Serial and H-MVIP Interface Configuration register. CASED[1:7] shares the same pins as ED[2,6,10,14,18,22,26].
PROPRIETARY AND CONFIDENTIAL
50
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Pin Name CCSED
Type Input
Pin Function No. P1 Common Channel Signaling Egress Data (CCSED). In T1 mode CCSED carries the 28 common channel signaling channels to be transmitted in each of the 28 T1s. In E1 mode CCSED carries up to 3 timeslots (15,16, 31) to be transmitted in each of the 21 E1s. CCSED is formatted according to the MVIP standard. CCSED is aligned to the common MVIP 16.384Mb/s clock, CMV8MCLK, frame pulse clock, CMVFPC, and frame pulse, CMVFPB. CCSED is sampled on every second rising or falling edge of CMV8MCLK as fixed by the common MVIP frame pulse clock, CMVFPC. The sampling edge of CMV8MCLK is selected via the CMVEDE bit in the Master Common Ingress Serial and H-MVIP Interface Configuration register.
Recovered T1 and E1 Clocks RECVCLK1 Output D22 Recovered Clock 1 (RECVCLK1). This clock output is a recovered and de-jittered clock from any one of the 28 T1 framers or 21 E1 framers. Output C22 Recovered Clock 2 (RECVCLK2). This clock output is a recovered and de-jittered clock from any one of the 28 T1 framers or 21 E1 framers. Input W12 Line Reference Clock (LREFCLK). This signal provides reference timing for the SONET telecom bus interface. On the incoming byte interface of the telecom bus, LDC1J1V1, LDDATA[7:0], LDDP, LDPL, LDTPL, LDV5, LDAIS and LAC1 are sampled of the rising edge or LREFCLK. In the outgoing byte interface, LADATA[7:0], LADP, LAPL, LAC1J1V1 and LAOE are updated on the rising edge of LREFCLK. This clock is nominally a 19.44MHz +/-20ppm clock with a 50% duty cycle. This clock can be external connected to SREFCLK. When in Transparent VT mode this clock must be connected to SREFCLK.
RECVCLK2
Telecom Line Side Interface LREFCLK
PROPRIETARY AND CONFIDENTIAL
51
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Pin Name LAC1
Type Input
Pin Function No. W13 Line Add C1 Frame Pulse (LAC1). The Add bus timing signal identifies the frame and multiframe boundaries on the Add Data bus LADATA[7:0]. LAC1 is set high to mark the first C1 byte of the first transport envelope frame of the 4 frame multiframe on the LADATA[7:0] bus. LAC1 need not be presented on every occurrence of the multiframe . LAC1 is sampled on the rising edge of LREFCLK.
LAC1J1V1
Output AA11 Line Add Bus Composite Timing Signal (LAC1J1V1). The Add bus composite timing signal identifies the frame, payload and tributary multiframe boundaries on the Line Add Data bus LADATA[7:0]. LAC1J1V1 pulses high with the Line Add Payload Active signal LAPL set low to mark the first STS-1 (STM-0/AU3) identification byte or equivalently the STM identification byte C1. Optionally the LAC1J1V1 signal pulses high with LAPL set high to mark the path trace byte J1. Optionally the LAC1J1V1 signal pulses high on the V1 byte to indicate tributary multiframe boundaries. In a system with multiple TEMUXs sharing the same Line Add bus only one device should have LAC1J1V1 connected. All devices must be configured via the LOCK0 bits in the Master SONET/SDH Configuration and TTMP Telecom Interface Configuartion registers for the same J1 location corresponding to a pointer offset of 0 or 522. LAC1J1V1 is updated on the rising edge of LREFCLK.
PROPRIETARY AND CONFIDENTIAL
52
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Pin Name LAOE
Type
Pin Function No.
Output AB11 Line Add Bus Output Enable (LAOE). The Add Bus output enable signal is asserted high whenever the Line Add Bus is being driven which is co-coincident with the Line Add bus outputs coming out of tri-state. This pin is intended to control an external multiplexer when multiple TEMUXs are driving the telecom Add bus during their individual tributaries. This same function is accomplished with the Add bus tristate drivers but increased tolerance to tributary configuration problems is possible with an external mux. This output is controlled via the LAOE bit in the TTMP Tributary Control registers. LAOE is updated on the rising edge of LREFCLK.
LADATA[0] LADATA[1] LADATA[2] LADATA[3] LADATA[4] LADATA[5] LADATA[6] LADATA[7]
Output AB8 Line Add Bus Data (LADATA[7:0]). The add bus data Tristate W7 contains the SONET transmit payload data in byte W8 serial format. All transport overhead bytes are set to AB9 00h. The phase relation of the SPE (VC) to the W9 transport frame is determined by the Add Bus Y10 composite timing signal LAC1J1V1 and is SW AA10 selectable to be either 0 or 522. LADATA[7] is the most AB10 significant bit (corresponding to bit 1 of each serial word, the first bit to be transmitted). LADATA[7:0] is only asserted during the SONET/SDH tributaries assigned to this device as determined by the LAOE bit in the TTMP Tributary Control registers. LADATA[7:0] is updated on the rising edge of LREFCLK.
PROPRIETARY AND CONFIDENTIAL
53
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Pin Name LADP
Type
Pin Function No.
Output W10 Line Add Bus Data Parity (LADP). The Add Bus data parity signal carries the parity of the outgoing signals. Tristate The parity calculation encompasses the LADATA[7:0] bus and optionally the LAC1J1V1 and LAPL signals. LAC1J1V1 and LAPL can be included in the parity calculation by setting the INCLAC1J1V1 and INCLAPL register bits in the Master SONET/SDH Egress Configuration register high, respectively. Odd parity is selected by setting the LAOP register bit in the same register high and even parity is selected by setting the LAOP bit low. LADP is only asserted during the SONET/SDH tributaries assigned to this device as determined by the LAOE bit in the TTMP Tributary Control registers. LADP is updated on the rising edge of LREFCLK.
LAPL
Output Y11 Line Add Bus Payload Active (LAPL). The Add Bus payload active signal identifies the payload bytes on Tristate LADATA[7:0]. LAPL is set high during path overhead and payload bytes and low during transport overhead bytes. LAPL is only asserted during the SONET/SDH tributaries assigned to this device as determined by the LAOE bit in the TTMP Tributary Control registers. LAPL is updated on the rising edge of LREFCLK.
LDDATA[0] LDDATA[1] LDDATA[2] LDDATA[3] LDDATA[4] LDDATA[5] LDDATA[6] LDDATA[7]
Input
AA13 Line Drop Bus Data (LDDATA[7:0]). The drop bus Y13 data contains the SONET/SDH receive payload data in W14 byte serial format. LDDATA[7] is the most significant AB14 bit, corresponding to bit 1 of each serial word, the bit W15 transmitted first. W16 LDDATA[7:0] is sampled on the rising edge of AB15 LREFCLK. W17
PROPRIETARY AND CONFIDENTIAL
54
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Pin Name LDDP
Type Input
Pin Function No. AB16 Line Drop Bus Data Parity (LDDP). The incoming data parity signal carries the parity of the incoming signals. The parity calculation encompasses the LDDATA[7:0] bus and optionally the LDPL signal. LDPL can be included in the parity calculation by setting the INCLDPL bit in the Master SONET/SDH Ingress Configuration register high. Odd parity is selected by setting the LDOP bit in the Master SONET/SDH Ingress Configuration register high and even parity is selected by setting the LDOP bit low. LDDP is sampled on the rising edge of LREFCLK. Y16 Line Drop C1/J1 Frame Pulse (LDC1J1V1). The input C1/J1/V1 frame pulse identifies the transport envelope, synchronous payload envelope frame boundaries and optionallly multiframe alignment on the incoming SONET stream. LDC1J1V1 is set high while LDPL is low to mark the first C1 byte of the transport envelope frame on the LDDATA[7:0] bus. LDC1J1V1 is set high while LDPL is high to mark each J1 byte of the synchronous payload envelope(s) on the LDDATA[7:0] bus. LDC1J1V1 must be present at every occurrence of the first C1 and all J1 bytes. Optionally LDC1J1V1 indicates multiframe alignment when high during the first V1 bytes of each envelope. LDC1J1V1 is sampled on the rising edge of LREFCLK.
LDC1J1V1
Input
LDPL
Input
AA16 Line Drop Bus Payload Active (LDPL). The payload active signal identifies the bytes on LDDATA[7:0] that carry payload bytes. LDPL is set high during path overhead and payload bytes and low during transport overhead bytes. LDPL is set high during the H3 byte to indicate a negative pointer justification and low during the byte following H3 to indicate a positive pointer justification event. LDPL is sampled on the rising edge of LREFCLK.
PROPRIETARY AND CONFIDENTIAL
55
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Pin Name LDV5
Type Input
Pin Function No. AB17 Line Drop Bus V5 Byte (LDV5). The incoming tributary V5 byte signal marks the various tributary V5 bytes. LDV5 marks each tributary V5 byte on the LDDATA[7:0] bus when high. LDV5 is sampled on the rising edge of LREFCLK. AB13 Line Drop Bus Tributary Payload Active (LDTPL). The tributary payload active signal marks the bytes carrying the tributary payload which have been identified by an external payload processor. When this signal is available, the internal pointer processor can be bypassed. LDTPL is high during each tributary payload byte on the LDDATA[7:0] bus. In floating mode, LDTPL contains valid data only for bytes in the VC3 or VC4 virtual containers, or the STS-1 SPE. It should be ignored for bytes in the transport overhead. In locked mode, LDTPL is low for transport overhead. LDTPL is sampled on the rising edge of LREFCLK.
LDTPL
Input
LDAIS
Input
AB12 Line Drop Bus Tributary Path Alarm Indication Signal (LDAIS). The active high tributary path alarm indication signal identifies tributaries on the incoming data stream LDDATA[7:0] that are in AIS state. When this signal is available, the internal pointer processor can be bypassed. LDAIS is invalid when LDTPL is low. LDAIS is sampled on the rising edge of LREFCLK. AA17 Remote Alarm Port East Clock (RADEASTCK). The remote serial alarm port east clock provides timing for the east remote serial alarm port. It is nominally a 9.72 MHz clock, but can range from 1.344 MHz to 10 MHz. Inputs RADEASTFP and RADEAST are sampled on the rising edge of RADEASTCK.
RADEASTCK
Input
PROPRIETARY AND CONFIDENTIAL
56
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Pin Name RADEASTFP
Type Input
Pin Function No. AB18 Remote Alarm Port East Frame Pulse (RADEASTFP). The remote serial alarm port east frame pulse is used to locate the alarm bits of the individual tributaries in the east remote serial alarm port. RADEASTFP is set high to mark the first BIP-2 error bit of tributary TU #1 in TUG2 #1 of TUG3 #1 carried in RADEAST. RADEASTFP must be set high to mark every occurrence of this bit. TEMUX will not flywheel on RADEASTFP in order to accommodate a variety of RADEASTCK frequencies. RADEASTFP is sampled on the rising edge of RADEASTCK.
RADEAST
Input
W18 Remote Alarm Port Data East (RADEAST). The remote serial alarm port east carries the tributary path BIP-2 error count, RDI status, and RFI status in the east remote serial alarm port. The first BIP-2 error bit of tributary TU #1 in TUG2 #1 of TUG3 #1 on RADEAST is marked by a high level on RADEASTFP. The status carried on RADEAST is software selectable to be reported on the RDI, RFI and REI alarms and is selectable to be associated with any tributary on the outgoing data stream LADATA[7:0]. RADEAST is sampled on the rising edge of RADEASTCK.
RADWESTCK
Input
AA18 Remote Alarm Port West Clock (RADWESTCK). The remote serial alarm port west clock provides timing for the west remote serial alarm port. It is nominally a 9.72 MHz clock, but can range from 1.344 MHz to 10 MHz. Inputs RADWESTFP and RADWEST are sampled on the rising edge of RADWESTCK.
PROPRIETARY AND CONFIDENTIAL
57
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Pin Name RADWESTFP
Type Input
Pin Function No. AB19 Remote Alarm Port West Frame Pulse (RADWESTFP). The remote serial alarm port west frame pulse is used to locate the alarm bits of the individual tributaries in the west remote serial alarm port. RADWESTFP is set high to mark the first BIP-2 error bit of tributary TU #1 in TUG2 #1 of TUG3 #1 carried in RADWEST. RADWESTFP must be set high to mark every occurrence of this bit. TEMUX will not flywheel on RADWESTFP in order to accommodate a variety of RADWESTCK frequencies. RADWESTFP is sampled on the rising edge of RADWESTCK.
RADWEST
Input
W19 Remote Alarm Port Data West (RADWEST). The remote serial alarm port west carries the tributary path BIP-2 error count, RDI status, and RFI status in the west remote serial alarm port. The first BIP-2 error bit of tributary TU #1 in TUG2 #1 of TUG3 #1 on RADWEST is marked by a high level on RADWESTFP. The status carried on RADWEST is software selectable to be reported on the RDI, RFI and REI alarms and is selectable to be associated with any tributary on the outgoing data stream LADATA[7:0]. RADWESTFP is sampled on the rising edge of RADWESTCK.
CLK52M
Input
P3
52MHz Clock Reference (CLK52M). The 52Mhz clock reference is used to generate a gapped DS3 clock when demapping a DS3 from the SONET stream and also to generate a gapped DS3 clock when receiving a DS3 from the SBI bus interface. This clock has two nominal values. The first is a nominal 51.84MHz 50% duty cycle clock. The second is a nominal 44.928MHz 50% duty cycle clock. When this clock is not used this input must be connected to ground.
PROPRIETARY AND CONFIDENTIAL
58
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Scaleable Bandwidth Interconnect Interface SREFCLK Input B7 System Reference Clock (SREFCLK). This system reference clock is a nominal 19.44MHz +/-50ppm 50% duty cycle clock. This clock is common to both the add and drop sides of the SBI bus. When passing transparent virtual tributaries between the telecom bus and the SBI bus, SREFCLK must be the same as LREFCLK. System C1 Frame Pulse (SC1FP). The System C1 Frame Pulse is used to synchronize devices interfacing to the SBI bus. This signal is common to both the add and drop sides of the system SBI bus. By default, SC1FP is an input. The TEMUX can alternatively be configured to generate this frame pulse - as an output on SC1FP - for use by all other devices connected to the same SBI bus. Note that all devices interconnected via an SBI interface must be synchronized to an SC1FP signal from a single common source. As an input, SC1FP is sampled on the rising edge of SREFCLK. It normally indicates SBI mutiframe alignment, and thus should be asserted for a single SREFCLK cycle every 9720 SREFCLK cycles or some multiple thereof (i.e. every 9720*N SREFCLK cycles, where N is a positive integer). In synchronous SBI mode, however, SC1FP is used to indicate T1/E1 signaling multiframe alignment, and thus should be asserted for a single SREFCLK cycle once every 12 SBI mutiframes (48 T1/E1 frames or 116640 SREFCLK cycles). As an output, SC1FP is generated on the rising edge of SREFCLK. It normally indicates SBI mutiframe alignment by pulsing high once every 9720 SREFCLK cycles. In synchronous SBI mode, however, SC1FP is used to indicate T1/E1 signaling multiframe alignment by pulsing once every 12 SBI mutiframes (48 T1/E1 frames or 116640 SREFCLK cycles).
SC1FP
I/O
A6
PROPRIETARY AND CONFIDENTIAL
59
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
SADATA[0] SADATA[1] SADATA[2] SADATA[3] SADATA[4] SADATA[5] SADATA[6] SADATA[7]
Input
D6 C7 D4 B6 A5 B5 A4 C5
System Add Bus Data (SADATA[7:0]). The System add data bus is a time division multiplexed bus which carries the T1 and DS3 tributary data is byte serial format over the SBI bus structure. This device only monitors the add data bus during the timeslots assigned to this device. SADATA[7:0] is sampled on the rising edge of SREFCLK. This bus shares pins with ED[15,16,19,20,23,24,27,28]. System Add Bus Data Parity (SADP). The system add bus signal carries the even or odd parity for the add bus signals SADATA[7:0], SAPL and SAV5. The TEMUX monitors parity across all links on the add bus. SADP is sampled on the rising edge of SREFCLK. This signal shares a pin with signal ED[8].
SADP
Input
A2
SAPL
Input
B4
System Add Bus Payload Active (SAPL). The add bus payload active signal indicates valid data within the SBI bus structure. This signal must be high during all octets making up a tributary. This signal goes high during the V3 or H3 octet of a tributary to indicate negative timing adjustments between the tributary rate and the fixed SBI bus structure. This signal goes low during the octet after the V3 or H3 octet of a tributary to indicate positive timing adjustments between the tributary rate and the fixed SBI bus structure. The TEMUX only monitors the add bus payload active signal during the tributary timeslots assigned to this device. SAPL is sampled on the rising edge of SREFCLK. This signal shares a pin with signal ED[12].
PROPRIETARY AND CONFIDENTIAL
60
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
SAV5
Input
A3
System Add Bus Payload Indicator (SAV5). The add bus payload indicator locates the position of the floating payloads for each tributary within the SBI bus structure. Timing differences between the tributary timing and the synchronous SBI bus are indicated by adjustments of this payload indicator relative to the fixed SBI bus structure. All timing adjustments indicated by this signal must be accompanied by appropriate adjustments in the SAPL signal. The TEMUX only monitors the add bus payload Indicator signal during the tributary timeslots assigned to this device. SAV5 is sampled on the rising edge of SREFCLK. This signal shares a pin with signal ED[11].
SAJUST_REQ
Output D7 Tristate
System Add Bus Justification Request (SAJUST_REQ). The justification request signals the Link Layer device to speed up, slow down or maintain the rate which it is sending data to the TEMUX. This is only used when the TEMUX is the timing master for the tributary transmit direction. This active high signal indicates negative timing adjustments when asserted high during the V3 or H3 octet of the tributary. In response to this the Link Layer device sends an extra byte in the V3 or H3 octet of the next SBI bus multi-frame. Positive timing adjustments are requested by asserting justification request high during the octet following the V3 or H3 octet. The Link Layer device responds to this request by not sending an octet during the V3 or H3 octet of the next multi-frame. The TEMUX only drives the justification request signal during the tributary timeslots assigned to this device. SAJUST_REQ is updated on the rising edge of SREFCLK.
PROPRIETARY AND CONFIDENTIAL
61
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
SDDATA[0] SDDATA[1] SDDATA[2] SDDATA[3] SDDATA[4] SDDATA[5] SDDATA[6] SDDATA[7]
Output A12 System Drop Bus Data (SDDATA[7:0]). The System Tristate D12 drop data bus is a time division multiplexed bus which D11 carries the T1 and DS3 tributary data is byte serial A11 format over the SBI bus structure. This device only D10 drives the data bus during the timeslots assigned to this A10 device. B10 SDDATA[7:0] is updated on the rising edge of C10 SREFCLK. This bus shares pins with ID[15,16,19,20,23,24,27,28]. Output D9 Tristate System Drop Bus Data Parity (SDDP). The system drop bus signal carries the even or odd parity for the drop bus signals SDDATA[7:0], SDPL and SDV5. The TEMUX only drives the data bus parity during the timeslots assigned to this device unless configured for bus master mode. In this case, all undriven links should be driven externally with correctly generated parity. SDDP is updated on the rising edge of SREFCLK. This signal shares a pin with IFP[20].
SDDP
SDPL
Output D8 Tristate
System Drop Bus Payload Active (SDPB). The payload active signal indicates valid data within the SBI bus structure. This signal is asserted during all octets making up a tributary. This signal goes high during the V3 or H3 octet of a tributary to accommodate negative timing adjustments between the tributary rate and the fixed SBI bus structure. This signal goes low during the octet after the V3 or H3 octet of a tributary to accommodate positive timing adjustments between the tributary rate and the fixed SBI bus structure. The TEMUX only drives the payload active signal during the tributary timeslots assigned to this device. SDPL is updated on the rising edge of SREFCLK. This signal shares a pin with IFP[27].
PROPRIETARY AND CONFIDENTIAL
62
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
SDV5
Output A9 Tristate
System Drop Bus Payload Indicator (SDV5). The payload indicator locates the position of the floating payloads for each tributary within the SBI bus structure. Timing differences between the tributary timing and the synchronous SBI bus are indicated by adjustments of this payload indicator relative to the fixed SBI bus structure. All timing adjustments indicated by this signal are accompanied by appropriate adjustments in the SDPL signal. The TEMUX only drives the payload Indicator signal during the tributary timeslots assigned to this device. SDV5 is updated on the rising edge of SREFCLK. This signal shares a pin with IFP[28].
SBIACT
Output A8
SBI Output Active (SBIACT). The SBI Output Active indicator is high whenever the TEMUX is driving the SBI drop bus signals. This signal is used by other TEMUXs or other SBI devices to detect SBI configuration problems by detecting other devices driving the SBI bus during the same tributary as the device listening to this signal. This output is updated on the rising edge or SREFCLK. SBI Bus Activity Detection (SBIDET[1:0]). The SBI bus activity detect input detects tributary collisions between devices sharing the same SBI bus. Each SBI device driving the bus also drives an SBI active signal (SBIACT). This pair of activity detection inputs monitors the active signals from two other SBI devices. When unused this signal should be connected to ground. A collision is detected when either of SBIDET[1:0] signals are active concurrently with this device driving SBIACT. When collisions occur the SBI drivers are disabled and an interrupt is generated to signal the collision. These signals are sampled on the rising edge of SREFCLK. SBIDET[1] is shared with serial interface signal ED[7].
SBIDET[0] SBIDET[1]
Input
C8 A7
Microprocessor Interface
PROPRIETARY AND CONFIDENTIAL
63
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
INTB
Output A16 Active low Open-Drain Interrupt (INTB). This signal goes low when an unmasked interrupt event is OD detected on any of the internal interrupt sources. Note that INTB will remain low until all active, unmasked interrupt sources are acknowledged at their source. Input D16 Active Low Chip Select (CSB). This signal is low during TEMUX register accesses. CSB has an integral pull up resistor. B16 Active Low Read Enable (RDB). This signal is low during TEMUX register read accesses. The TEMUX drives the D[7:0] bus with the contents of the addressed register while RDB and CSB are low. C15 Active Low Write Strobe (WRB). This signal is low during a TEMUX register write access. The D[7:0] bus contents are clocked into the addressed register on the rising WRB edge while CSB is low. C14 Bidirectional Data Bus (D[7:0]). This bus provides B14 TEMUX register read and write accesses. A14 D14 C13 B13 A13 D13 A17 C16 D18 D19 B17 A18 A19 A20 C18 B19 B20 A21 C19 B21 Address Bus (A[13:0]). This bus selects specific registers during TEMUX register accesses. Signal A[13] selects between normal mode and test mode register access. A[13] has an integral pull down resistor.
CSB
RDB
Input
WRB
Input
D[0] D[1] D[2] D[3] D[4] D[5] D[6] D[7] A[0] A[1] A[2] A[3] A[4] A[5] A[6] A[7] A[8] A[9] A[10] A[11] A[12] A[13] RSTB
I/O
Input
Input
A22 Active Low Reset (RSTB). This signal provides an asynchronous TEMUX reset. RSTB is a Schmitt triggered input with an integral pull up resistor.
PROPRIETARY AND CONFIDENTIAL
64
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
ALE
Input
D17 Address Latch Enable (ALE). This signal is active high and latches the address bus A[13:0] when low. When ALE is high, the internal address latches are transparent. It allows the TEMUX to interface to a multiplexed address/data bus. The ALE input has an integral pull up resistor. C3 Test Clock (TCK). This signal provides timing for test operations that can be carried out using the IEEE P1149.1 test access port. Test Mode Select (TMS). This signal controls the test operations that can be carried out using the IEEE P1149.1 test access port. TMS is sampled on the rising edge of TCK. TMS has an integral pull up resistor. Test Data Input (TDI). This signal carries test data into the TEMUX via the IEEE P1149.1 test access port. TDI is sampled on the rising edge of TCK. TDI has an integral pull up resistor. Test Data Output (TDO). This signal carries test data out of the TEMUX via the IEEE P1149.1 test access port. TDO is updated on the falling edge of TCK. TDO is a tri-state output which is inactive except when scanning of data is in progress. Active low Test Reset (TRSTB). This signal provides an asynchronous TEMUX test access port reset via the IEEE P1149.1 test access port. TRSTB is a Schmitt triggered input with an integral pull up resistor. TRSTB must be asserted during the power up sequence. Note that if not used, TRSTB must be connected to the RSTB input.
JTAG Interface TCK Input
TMS
Input
C2
TDI
Input
C4
TDO
Output B3
TRSTB
Input
B1
Miscellaneous Pins TEMUXSELB Input AA2 TEMUX Mode Select (TEMUXSELB). The TEMUX Mode Select pin is used for internal testing and must be connected to ground for proper operation. TEMUXSELB has an integral pull up resistor A1 B2 No Connect. These pins are not connected to any internal logic.
NO CONNECT
PROPRIETARY AND CONFIDENTIAL
65
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Power and Ground Pins VDD3.3[17] VDD3.3[16] VDD3.3[15] VDD3.3[14] VDD3.3[13] VDD3.3[12] VDD3.3[11] VDD3.3[10] VDD3.3[9] VDD3.3[8] VDD3.3[7] VDD3.3[6] VDD3.3[5] VDD3.3[4] VDD3.3[3] VDD3.3[2] VDD3.3[1] VDD2.5[8] VDD2.5[7] VDD2.5[6] VDD2.5[5] VDD2.5[4] VDD2.5[3] VDD2.5[2] VDD2.5[1] Power N2 Power (VDD3.3[17:1]). The VDD3.3[17:1] pins should AA12 be connected to a well decoupled +3.3V DC power L21 supply. C12 F3 M4 U3 Y5 AA9 AA14 Y18 U20 M21 F20 C17 B11 D5 Power J2 Power (VDD2.5[8:1]). The VDD2.5[8:1] pins should R2 be connected to a well-decoupled +2.5V DC power AA8 supply. AA15 R21 H21 A15 C9
PROPRIETARY AND CONFIDENTIAL
66
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
VSS3.3[22] VSS3.3[21] VSS3.3[20] VSS3.3[19] VSS3.3[18] VSS3.3[17] VSS3.3[16] VSS3.3[15] VSS3.3[14] VSS3.3[13] VSS3.3[12] VSS3.3[11] VSS3.3[10] VSS3.3[9] VSS3.3[8] VSS3.3[7] VSS3.3[6] VSS3.3[5] VSS3.3[4] VSS3.3[3] VSS3.3[2] VSS3.3[1] VSSQ[4] VSSQ[3] VSSQ[2] VSSQ[1] VSS2.5[8] VSS2.5[7] VSS2.5[6] VSS2.5[5] VSS2.5[4] VSS2.5[3] VSS2.5[2] VSS2.5[1]
Ground N3 Ground (VSS3.3[22:1]). The VSS3.3[22:1] pins Y12 should be connected to GND. L20 B12 E2 L4 V2 AA4 Y9 W11 Y14 Y17 AA19 V21 M20 J21 E21 B18 D15 C11 B8 C6 Ground N3 Ground (VSSQ[4:1]). The VSSQ[4:1] pins should be Y12 connected to GND. L20 B12 J3 Ground (VSS2.5[8:1]). The VSS2.5[8:1] pins should R3 be connected to GND. Y8 Y15 R20 H20 B15 B9
PROPRIETARY AND CONFIDENTIAL
67
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
VSS[36] VSS[35] VSS[34] VSS[33] VSS[32] VSS[31] VSS[30] VSS[29] VSS[28] VSS[27] VSS[26] VSS[25] VSS[24] VSS[23] VSS[22] VSS[21] VSS[20] VSS[19] VSS[18] VSS[17] VSS[16] VSS[15] VSS[14] VSS[13] VSS[12] VSS[11] VSS[10] VSS[9] VSS[8] VSS[7] VSS[6] VSS[5] VSS[4] VSS[3] VSS[2] VSS[1]
J14 Thermal Ground (VSS). The VSS[36:1] pins should J13 be connected to a ground plane for enhanced thermal J12 conductivity. J11 J10 J9 K14 K13 K12 K11 K10 K9 L14 L13 L12 L11 L10 L9 M14 M13 M12 M11 M10 M9 N14 N13 N12 N11 N10 N9 P14 P13 P12 P11 P10 P9
PROPRIETARY AND CONFIDENTIAL
68
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
NOTES ON PIN DESCRIPTIONS: 1. All TEMUX inputs and bi-directionals present minimum capacitive loading and operate at TTL logic levels. 2. All TEMUX outputs and bi-directionals have at least 2 mA drive capability. The bidirectional data bus outputs, D[7:0], have 4 mA drive capability. The outputs TCLK, TPOS/TDAT, TNEG/TMFP, RGAPCLK/RSCLK, RDATAO, RFPO/RMFPO, ROVRHD, TFPO/TMFPO/TGAPCLK, SBIACT, LAOE, RECVCLK1, RECVCLK2, MVID[7:0], CASID[7:0], CCSID and INTB have 4 mA drive capability. The SBI outputs and telecom bus outputs, SDDATA[7:0], SDDP, SDPL, SDV5, SAJUST_REQ, LAC1J1V1, LADATA[7:0], LADP and LAPL, have 8mA drive capability. The bidirectional SBI signal SC1FP has 8mA drive capability. 3. IOL = -2mA for others. 4. Inputs RSTB, ALE, TMS, TDI, TRSTB, and CSB have internal pull-up resistors. 5. Input A[13] has an internal pull-down resistor. 6. All unused inputs should be connected to GROUND. 7. All TEMUX outputs can be tristated under control of the IEEE P1149.1 test access port, even those which do not tristate under normal operation. All outputs and bi-directionals are 5 V tolerant when tristated. 8. Power to the VDD3.3 and VDDQ pins should be applied before power to the VDD2.5 pins is applied. Similarly, power to the VDD2.5 pins should be removed before power to the VDD3.3 and VDDQ pins are removed. 9. All TEMUX inputs are 5V tolerant.
PROPRIETARY AND CONFIDENTIAL
69
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
9 9.1
FUNCTIONAL DESCRIPTION T1 Framer (T1-FRMR) The T1 framing function is provided by the T1-FRMR block. This block searches for the framing bit position in the ingress stream. It works in conjunction with the FRAM block to search for the framing bit pattern in the standard superframe (SF), or extended superframe (ESF) framing formats. When searching for frame, the FRMR simultaneously examines each of the 193 (SF) or each of the 772 (ESF) framing bit candidates. The FRAM block is addressed and controlled by the FRMR while frame synchronization is acquired. The time required to acquire frame alignment to an error-free ingress stream, containing randomly distributed channel data (i.e. each bit in the channel data has a 50% probability of being 1 or 0), is dependent upon the framing format. For SF format, the T1-FRMR block will determine frame alignment within 4.4ms 99 times out of 100. For ESF format, the T1-FRMR will determine frame alignment within 15 ms 99 times out of 100. Once the T1-FRMR has found frame, the ingress data is continuously monitored for framing bit errors, bit error events (a framing bit error in SF or a CRC-6 error in ESF), and severely errored framing events. The T1-FRMR also detects out-offrame, based on a selectable ratio of framing bit errors. The T1-FRMR can also be disabled to allow reception of unframed data.
9.2
E1 Framer (E1-FRMR) The E1 framing function is provided by the E1-FRMR block. The E1-FRMR block searches for basic frame alignment, CRC multiframe alignment, and channel associated signaling (CAS) multiframe alignment in the incoming recovered PCM stream. Once the E1-FRMR has found basic (or FAS) frame alignment, the incoming PCM data stream is continuously monitored for FAS/NFAS framing bit errors. Framing bit errors are accumulated in the framing bit error counter contained in the PMON block. Once the E1-FRMR has found CRC multiframe alignment, the PCM data stream is continuously monitored for CRC multiframe alignment pattern errors, and CRC-4 errors. CRC-4 errors are accumulated in the CRC error counter of the PMON block. Once the E1-FRMR has found CAS multiframe alignment, the PCM data is continuously monitored for CAS multiframe alignment pattern errors. The E1-FRMR also detects and indicates loss of basic frame, loss of CRC multiframe, and loss of CAS multiframe, based
PROPRIETARY AND CONFIDENTIAL
70
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
on user-selectable criteria. The reframe operation can be initiated by software (via the E1-FRMR Frame Alignment Options Register), by excessive CRC errors, or when CRC multiframe alignment is not found within 400 ms. The E1-FRMR also identifies the position of the frame, the CAS multiframe, and the CRC multiframe. The E1-FRMR extracts the contents of the International bits (from both the FAS frames and the NFAS frames), the National bits, and the Extra bits (from timeslot 16 of frame 0 of the CAS multiframe), and stores them in the E1-FRMR International/National Bits register and the E1-FRMR Extra Bits register. Moreover, the FRMR also extracts submultiframe-aligned 4-bit codewords from each of the National bit positions Sa4 to Sa8, and stores them in microprocessor-accessible registers that are updated every CRC submultiframe. The E1-FRMR identifies the raw bit values for the Remote (or distant frame) Alarm (bit 3 in timeslot 0 of NFAS frames) and the Remote Signaling Multiframe (or distant multiframe) Alarm (bit 6 of timeslot 16 of frame 0 of the CAS multiframe) via the E1-FRMR International/National Bits Register, and the E1-FRMR Extra Bits Register respectively. Access is also provided to the "debounced" remote alarm and remote signaling multiframe alarm bits which are set when the corresponding signals have been a logic 1 for 2 or 3 consecutive occurrences, as per Recommendation O.162. Detection of AIS and timeslot 16 AIS are provided. AIS is also integrated, and an AIS Alarm is indicated if the AIS condition has persisted for at least 100 ms. The out of frame (OOF=1) condition is also integrated, indicating a Red Alarm if the OOF condition has persisted for at least 100 ms. An interrupt may be generated to signal a change in the state of any status bits (OOF, OOSMF, OOCMF, AIS or RED), and to signal when any event (RAI, RMAI, AISD, TS16AISD, COFA, FER, SMFER, CMFER, CRCE or FEBE) has occurred. Additionally, interrupts may be generated every frame, CRC submultiframe, CRC multiframe or signaling multiframe. Basic Frame Alignment Procedure The E1-FRMR searches for basic frame alignment using the algorithm defined in ITU-T Recommendation G.706 sections 4.1.2 and 4.2.
PROPRIETARY AND CONFIDENTIAL
71
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
The algorithm finds frame alignment by using the following sequence: 1. Search for the presence of the correct 7-bit FAS (`0011011'); 2. Check that the FAS is absent in the following frame by verifying that bit 2 of the assumed non-frame alignment sequence (NFAS) TS 0 byte is a logic 1; 3. Check that the correct 7-bit FAS is present in the assumed TS 0 byte of the next frame. If either of the conditions in steps 2 or 3 are not met, a new search for frame alignment is initiated in the bit immediately following the second 7-bit FAS sequence check. This "hold-off" is done to ensure that new frame alignment searches are done in the next bit position, modulo 512. This facilitates the discovery of the correct frame alignment, even in the presence of fixed timeslot data imitating the FAS. Once frame alignment is found, the block sets the OOF indication low, indicates a change of frame alignment (if it occurred), and monitors the frame alignment signal, indicating errors occurring in the 7-bit FAS pattern and in bit 2 of NFAS frames, and indicating the debounced value of the Remote Alarm bit (bit 3 of NFAS frames). Using debounce, the Remote Alarm bit has <0.00001% probability of being falsely indicated in the presence of a 10-3 bit error rate. The block declares loss of frame alignment if 3 consecutive FASs have been received in error or, additionally, if bit 2 of NFAS frames has been in error for 3 consecutive occasions. In the presence of a random 10-3 bit error rate the frame loss criteria provides a mean time to falsely lose frame alignment of >12 minutes. The E1-FRMR can be forced to initiate a basic frame search at any time when any of the following conditions are met: * * * the software re-frame bit in the E1-FRMR Frame Alignment Options register goes to logic 1; the CRC Frame Find Block is unable to find CRC multiframe alignment; or the CRC Frame Find Block accumulates excessive CRC evaluation errors ( 915 CRC errors in 1 second) and is enabled to force a re-frame under that condition.
CRC Multiframe Alignment Procedure The E1-FRMR searches for CRC multiframe alignment by observing whether the International bits (bit 1 of TS 0) of NFAS frames follow the CRC multiframe alignment pattern. Multiframe alignment is declared if at least two valid CRC
PROPRIETARY AND CONFIDENTIAL
72
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
multiframe alignment signals are observed within 8 ms, with the time separating two alignment signals being a multiple of 2 ms Once CRC multiframe alignment is found, the OOCMFV register bit is set to logic 0, and the E1-FRMR monitors the multiframe alignment signal, indicating errors occurring in the 6-bit MFAS pattern, errors occurring in the received CRC and the value of the FEBE bits (bit 1 of frames 13 and 15 of the multiframe). The E1-FRMR declares loss of CRC multiframe alignment if basic frame alignment is lost. However, once CRC multiframe alignment is found, it cannot be lost due to errors in the 6-bit MFAS pattern. Under the CRC-to-non-CRC interworking algorithm, if the E1-FRMR can achieve basic frame alignment with respect to the incoming PCM data stream, but is unable to achieve CRC-4 multiframe alignment within the subsequent 400 ms, the distant end is assumed to be a non CRC-4 interface. The details of this algorithm are illustrated in the state diagram in Figure 8.
PROPRIETARY AND CONFIDENTIAL
73
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Figure 8
- CRC Multiframe Alignment Algorithm
Out of Frame
3 consecutive FASor NFAS errors; manual reframe; or excessive CRC errors
FAS_Find_1
FA S found NF AS not found nex t fram e
FAS_F ind_1_Pa r
FA S found NF AS not found nex t fram e
NFAS_Find
NF AS found nex t fram e FA S not found nex t fram e
NFAS_Find_Par
NF AS found nex t fram e FA S not found nex t fram e
FAS_Find_2
FA S found nex t fram e 8ms ex pire
Start 400ms timer and 8ms timer
FAS_Find_2_Par
FA S found nex t fram e
Start 8ms timer
BFA
CR CMF A
8m s expire and NOT( 400 ms exp ire)
Reset BFA to most recently found alignment
BFA_Par
400m s expire
CR CM FA_ Par
CRCto CRC Interworking
CR CM FA_ Par (Op tional setting)
CRCto non-C RC Interworking
PROPRIETARY AND CONFIDENTIAL
74
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Table 1
- E1-FRMR Framing States Out of Frame Yes Yes Yes No No No No No No No Out of Offline Frame No No No No No Yes Yes Yes No No
State FAS_Find_1 NFAS_Find FAS_Find_2 BFA CRC to CRC Interworking FAS_Find_1_Par NFAS_Find_Par FAS_Find_2_Par BFA_Par CRC to non-CRC Interworking
The states of the primary basic framer and the parallel/offline framer in the E1-FRMR block at each stage of the CRC multiframe alignment algorithm are shown in Table 1. From an out of frame state, the E1-FRMR attempts to find basic frame alignment in accordance with the FAS/NFAS/FAS G.706 Basic Frame Alignment procedure outlined above. Upon achieving basic frame alignment, a 400 ms timer is started, as well as an 8 ms timer. If two CRC multiframe alignment signals separated by a multiple of 2 ms are observed before the 8 ms timer has expired, CRC multiframe alignment is declared. If the 8 ms timer expires without achieving multiframe alignment, a new offline search for basic frame alignment is initiated. This search is performed in accordance with the Basic Frame Alignment procedure outlined above. However, this search does not immediately change the actual basic frame alignment of the system (i.e., PCM data continues to be processed in accordance with the first basic frame alignment found after an out of frame state while this frame alignment search occurs as a parallel operation). When a new basic frame alignment is found by this offline search, the 8 ms timer is restarted. If two CRC multiframe alignment signals separated by a multiple of 2 ms are observed before the 8 ms timer has expired, CRC multiframe alignment is declared and the basic frame alignment is set accordingly (i.e., the basic frame alignment is set to correspond to the frame alignment found by the parallel offline search, which is also the basic frame alignment corresponding to the newly found CRC multiframe alignment). Subsequent expirations of the 8 ms timer will likewise reinitiate a new search for basic frame alignment. If, however, the 400 ms timer expires at any time during this procedure, the E1-FRMR stops searching for CRC multiframe alignment and declares CRC-to-non-CRC interworking. In this mode, the E1-FRMR may be
PROPRIETARY AND CONFIDENTIAL
75
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
optionally set to either halt searching for CRC multiframe altogether, or may continue searching for CRC multiframe alignment using the established basic frame alignment. In either case, no further adjustments are made to the basic frame alignment, and no offline searches for basic frame alignment occur once CRC-to-non-CRC interworking is declared: it is assumed that the established basic frame alignment at this point is correct. AIS Detection When an unframed all-ones receive data stream is received, an AIS defect is indicated by setting the AISD bit to logic 1 when fewer than three zero bits are received in 512 consecutive bits or, optionally, in each of two consecutive periods of 512 bits. The AISD bit is reset to logic 0 when three or more zeros in 512 consecutive bits or in each of two consecutive periods of 512 bits. Finding frame alignment will also cause the AISD bit to be set to logic 0. Signaling Frame Alignment Once the basic frame alignment has been found, the E1-FRMR searches for Channel Associated Signaling (CAS) multiframe alignment using the following G.732 compliant algorithm: signaling multiframe alignment is declared when at least one non-zero time slot 16 bit is observed to precede a time slot 16 containing the correct CAS alignment pattern, namely four zeros ("0000") in the first four bit positions of timeslot 16. Once signaling multiframe alignment has been found, the E1-FRMR sets the OOSMFV bit of the E1-FRMR Framing Status register to logic 0, and monitors the signaling multiframe alignment signal, indicating errors occurring in the 4-bit pattern, and indicating the debounced value of the Remote Signaling Multiframe Alarm bit (bit 6 of timeslot 16 of frame 0 of the multiframe). Using debounce, the Remote Signaling Multiframe Alarm bit has < 0.00001% probability of being falsely indicated in the presence of a 10-3 bit error rate. The block declares loss of CAS multiframe alignment if two consecutive CAS multiframe alignment signals have been received in error, or additionally, if all the bits in time slot 16 are logic 0 for 1 or 2 (selectable) CAS multiframes. Loss of CAS multiframe alignment is also declared if basic frame alignment has been lost. National Bit Extraction The E1-FRMR extracts and assembles the submultiframe-aligned National bit codewords Sa4[1:4] , Sa5[1:4] , Sa6[1:4] , Sa7[1:4] and Sa8[1:4]. The
PROPRIETARY AND CONFIDENTIAL
76
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
corresponding register values are updated upon generation of the CRC submultiframe interrupt. This E1-FRMR also detects the V5.2 link ID signal, which is detected when 2 out of 3 Sa7 bits are zeros. Upon reception of this Link ID signal, the V52LINKV bit of the E1-FRMR Framing Status register is set to logic 1. This bit is cleared to logic 0 when 2 out of 3 Sa7 bits are ones. Alarm Integration The OOF and the AIS defects are integrated, verifying that each condition has persisted for 104 ms ( 6 ms) before indicating the alarm condition. The alarm is removed when the condition has been absent for 104 ms ( 6 ms). The AIS alarm algorithm accumulates the occurrences of AISD (AIS detection). The E1-FRMR counts the occurrences of AISD over a 4 ms interval and indicates a valid AIS is present when 13 or more AISD indications (of a possible 16) have been received. Each interval with a valid AIS presence indication increments an interval counter which declares AIS Alarm when 25 valid intervals have been accumulated. An interval with no valid AIS presence indication decrements the interval counter. The AIS Alarm declaration is removed when the counter reaches 0. This algorithm provides a 99.8% probability of declaring an AIS Alarm within 104 ms in the presence of a 10-3 mean bit error rate. The Red alarm algorithm monitors occurrences of OOF over a 4 ms interval, indicating a valid OOF interval when one or more OOF indications occurred during the interval, and indicating a valid in frame (INF) interval when no OOF indication occurred for the entire interval. Each interval with a valid OOF indication increments an interval counter which declares Red Alarm when 25 valid intervals have been accumulated. An interval with valid INF indication decrements the interval counter; the Red Alarm declaration is removed when the counter reaches 0. This algorithm biases OOF occurrences, leading to declaration of Red alarm when intermittent loss of frame alignment occurs. The E1-FRMR can also be disabled to allow reception of unframed data. 9.3 Performance Monitor Counters (T1/E1-PMON) The Performance Monitor Counters function is provided by the PMON block. The block accumulates CRC error events, Frame Synchronization bit error events, and Out Of Frame events, or optionally, Change of Frame Alignment (COFA) events with saturating counters over consecutive intervals as defined by the period of the supplied transfer clock signal (typically 1 second). When the transfer clock signal is applied, the PMON transfers the counter values into
PROPRIETARY AND CONFIDENTIAL
77
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
holding registers and resets the counters to begin accumulating events for the interval. The counters are reset in such a manner that error events occurring during the reset are not missed. If the holding registers are not read between successive transfer clocks, an OVERRUN register bit is asserted. Generation of the transfer clock within the TEMUX chip is performed by writing to any counter register location or by writing to the Global PMON Update register. The holding register addresses are contiguous to facilitate faster polling operations. 9.4 Bit Oriented Code Detector (RBOC) The Bit Oriented Code detection function is provided by the RBOC block. This block detects the presence of 63 of the possible 64 bit oriented codes transmitted in the T1 Facility Data Link channel in ESF framing format, as defined in ANSI T1.403 and in TR-TSY-000194 or in the DS3 C-bit parity far-end Th alarm and control (FEAC) channel. The 64 code (111111) is similar to the HDLC flag sequence and is used by the RBOC to indicate no valid code received. Bit oriented codes are received on the Facility Data Link channel or FEAC channel as a 16-bit sequence consisting of 8 ones, a zero, 6 code bits, and a trailing zero (111111110xxxxxx0). BOCs are validated when repeated at least 10 times. The RBOC can be enabled to declare a received code valid if it has been observed for 8 out of 10 times or for 4 out of 5 times, as specified by the AVC bit in the RBOC Configuration/Interrupt Enable register. The RBOC declares that the code is removed if two code sequences containing code values different from the detected code are received in a moving window of ten code periods. Valid BOC are indicated through the RBOC Interrupt Status register. The BOC bits are set to all ones (111111) if no valid code has been detected. An interrupt is generated to signal when a detected code has been validated, or optionally, when a valid code goes away (i.e. the BOC bits go to all ones). 9.5 HDLC Receiver (RDLC) The RDLC is a microprocessor peripheral used to receive HDLC frames on the 4kHz ESF facility data link, the E1 Sa-bit data link, the DS3 C-bit parity Path Maintenance Data Link or a specified channel within a T1 or E1 stream. The RDLC detects the change from flag characters to the first byte of data, removes stuffed zeros on the incoming data stream, receives packet data, and calculates the CRC-CCITT frame check sequence (FCS).
PROPRIETARY AND CONFIDENTIAL
78
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
In the address matching mode, only those packets whose first data byte matches one of two programmable bytes or the universal address (all ones) are stored in the FIFO. The two least significant bits of the address comparison can be masked for LAPD SAPI matching. Received data is placed into a 128-level FIFO buffer. An interrupt is generated when a programmable number of bytes are stored in the FIFO buffer. Other sources of interrupt are detection of the terminating flag sequence, abort sequence, or FIFO buffer overrun. The Status Register contains bits which indicate the overrun or empty FIFO status, the interrupt status, and the occurrence of first flag or end of message bytes written into the FIFO. The Status Register also indicates the abort, flag, and end of message status of the data just read from the FIFO. On end of message, the Status Register indicates the FCS status and if the packet contained a non-integer number of bytes. 9.6 T1 Alarm Integrator (ALMI) The T1 Alarm Integration function is provided by the ALMI block. This block detects the presence of Yellow, Red, and AIS Carrier Fail Alarms (CFA) in SF, or ESF formats. The alarm detection and integration is compatible with the specifications defined in ANSI T1.403 and TR-TSY-000191. The ALMI block declares the presence of Yellow alarm when the Yellow pattern has been received for 425 ms ( 50 ms); the Yellow alarm is removed when the Yellow pattern has been absent for 425 ms ( 50 ms). The presence of Red alarm is declared when an out-of-frame condition has been present for 2.55 sec ( 40 ms); the Red alarm is removed when the out-of-frame condition has been absent for 16.6 sec ( 500 ms). The presence of AIS alarm is declared when an out-of-frame condition and all-ones in the PCM data stream have been present for 1.5 sec (100 ms); the AIS alarm is removed when the AIS condition has been absent for 16.8 sec (500 ms). CFA alarm detection algorithms operate in the presence of a 10-3 bit error rate. The ALMI also indicates the presence or absence of the Yellow, Red, and AIS alarm signal conditions over 40 ms, 40 ms, and 60 ms intervals, respectively, allowing an external microprocessor to integrate the alarm conditions via software with any user-specific algorithms. Alarm indication is provided through internal register bits.
PROPRIETARY AND CONFIDENTIAL
79
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
9.7
Elastic Store (ELST) The Elastic Store (ELST) synchronizes ingress frames to the common ingress clock and frame pulse (CICLK, CIFP) in the Clock Slave ingress modes or to the common ingress H-MVIP clock and frame pulse (CMV8MCLK, CMVFP, CMVFPC) in H-MVIP modes. The frame data is buffered in a two frame circular data buffer. Input data is written to the buffer using a write pointer and output data is read from the buffer using a read pointer. When the elastic store is being used, if the average frequency of the incoming data is greater than the average frequency of the backplane clock, the write pointer will catch up to the read pointer and the buffer will be filled. Under this condition a controlled slip will occur when the read pointer crosses the next frame boundary. The subsequent ingress frame is deleted. If the average frequency of the incoming data is less than the average frequency of the backplane clock, the read pointer will catch up to the write pointer and the buffer will be empty. Under this condition a controlled slip will occur when the read pointer crosses the next frame boundary. The previous ingress frame is repeated. A slip operation is always performed on a frame boundary. When the ingress timing is recovered from the receive data the elastic store can be bypassed to eliminate the 2 frame delay. In this configuration (the Clock Master ingress modes), the elastic store is used to synchronize the ingress frames to the transmit line clock so that per-DS0 loopbacks may be enabled. To allow for the extraction of signaling information in the data channels, superframe identification is also passed through the ELST. For payload conditioning, the ELST may optionally insert a programmable idle code into all channels when the framer is out of frame synchronization. This code is set to all 1's when the ELST is reset. If the data is required to pass through the TEMUX unchanged during an out-offrame condition, then the elastic store may be bypassed.
9.8
Signaling Elastic Stores (RX-SIG-ELST and TX_SIG-ELST) There are two additional elastic stores used to adapt the differences in rate between the CAS or CCS H-MVIP signaling rates and the serial clock and data or SBI data rates when in simultaneous SBI or serial clock and data with
PROPRIETARY AND CONFIDENTIAL
80
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
signaling H-MVIP. These elastic stores are identical to the elastic store described in section 9.7. When simultaneous SBI with CAS or CCS H-MVIP is selected by the SYSOPT[2:0] bits in the Global Configuration register these elastic stores eliminate the need for the H-MVIP interface clock and frame alignment to be externally synchronized to the rate and frame alignment of the individual links carries over the SBI interface. Any rate differences between the H-MVIP interface and an individual link will result in a controlled slip in the CAS or CCS data relative to the data channels of the individual T1 or E1 links. When simultaneous serial clock and data with CCS H-MVIP is selected these elastic stores eliminate the need for the H-MVIP interface clock and frame alignment to be externally synchronized to the rate and frame alignment of the individual serial streams. As with simultaneous SBI mode, any rate differences between the H-MVIP interface and an individual link will result in a controlled slip in the CCS signaling relative to the data channels of the individual T1 or E1 links. 9.9 Signaling Extractor (SIGX) The Signaling Extraction (SIGX) block provides channel associated signaling (CAS) extraction from an E1 signaling multi-frame or from ESF, and SF T1 formats. In T1 mode, the SIGX block provides signaling bit extraction from the received data stream for ESF and SF framing formats. It selectively debounces the bits, and serializes the results onto the ISIG[x] outputs or CAS bits within the SBI Bus structure. Debouncing is performed on individual signaling bits. This ISIG[x] output is channel aligned with ID[x] output, and the signaling bits are repeated for the entire superframe, allowing downstream logic to reinsert signaling into any frame, as determined by system timing. The signaling data stream contains the A,B,C,D bits in the lower 4 channel bit locations (bits 5, 6, 7 and 8) in ESF framing format; in SF format the A and B bits are repeated in locations C and D (i.e. the signaling stream contains the bits ABAB for each channel). The SIGX block contains three superframes worth of signal buffering to ensure that there is a greater than 95% probability that the signaling bits are frozen in the correct state for a 50% ones density out-of-frame condition, as specified in TR-TSY-000170 and BELL PUB 43801. With signaling debounce enabled, the per-channel signaling state must be in the same state for 2 superframes before appearing on the serial output stream. The SIGX block provides one superframe or signaling-multiframe of signal freezing on the occurrence of slips. When a slip event occurs, the SIGX freezes
PROPRIETARY AND CONFIDENTIAL
81
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
the output signaling for the entire superframe in which the slip occurred; the signaling is unfrozen when the next slip-free superframe occurs. The SIGX also provides control over timeslot signaling bit fixing, data inversion and signaling debounce on a per-timeslot basis. The SIGX block also provides an interrupt to indicate a change of signaling state on a per channel basis. 9.10 Receive Per-Channel Serial Controller (RPSC) The RPSC allows data and signaling trunk conditioning to be applied on the ingress stream on a per-channel basis. It also allows per-channel control of data inversion, the extraction of clock and data on ICLK[x] and ID[x] (when the Clock Master: NxChannel mode is active), and the detection or generation of pseudorandom patterns. The RPSC operates on the data after its passage through ELST, so that data and signaling conditioning may overwrite the ELST trouble code. 9.11 Basic Transmitter (XBAS) The T1 Basic Transmitter (XBAS) block generates the 1.544 Mbit/s T1 data stream according to SF or ESF frame formats. In concert with the Transmit Per-Channel Serial Controller (TPSC), the XBAS block, provides per-channel control of idle code substitution, data inversion (either all 8 bits, sign bit magnitude or magnitude only), and zero code suppression. Three types of zero code suppression (GTE, Bell and "jammed bit 8") are supported and selected on a per-channel basis to provide minimum ones density control. An internal signaling control stream provides per-channel control of robbed bit signaling and selection of the signaling source. All channels can be forced into a trunk conditioning state (idle code substitution and signaling conditioning) by use of the Master Trunk Conditioning (MTRK) bit in the T1-XBAS Configuration Register. A data link is provided for ESF mode. The data link sources include bit oriented codes and HDLC messages. Support is provided for the transmission of AIS or Yellow alarm signals for all formats. The transmitter can be disabled for framing via the FDIS disable bit in the T1/E1 Transmit Framing and Bypass Options register. When transmitting ESF formatted data, the framing bit, datalink bit, or the CRC-6 bit from the egress stream can be by-passed to the output data stream via the same T1/E1 Transmit
PROPRIETARY AND CONFIDENTIAL
82
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Framing and Bypass Options register. Finally, the transmitter can be by-passed completely to provide a clear channel operating mode. 9.12 E1 Transmitter (E1-TRAN) The E1 Transmitter (E1-TRAN) generates a 2048 kbit/s data stream according to ITU-T recommendations, providing individual enables for frame generation, CRC multiframe generation, and channel associated signaling (CAS) multiframe generation. In concert with Transmit Per-Channel Serial Controller (TPSC), the E1-TRAN block provides per-timeslot control of idle code substitution, data inversion, digital milliwatt substitution, selection of the signaling source and CAS data. All timeslots can be forced into a trunk conditioning state (idle code substitution and signaling substitution) by use of the master trunk conditioning bit in the E1-TRAN Transmit Alarm/Diagnostic Control register. Common Channel Signaling (CCS) is supported in time slot 16 through the Transmit Channel Insertion (TXCI) block. Support is provided for the transmission of AIS and TS16 AIS, and the transmission of remote alarm (RAI) and remote multiframe alarm signals. The National Use bits (Sa-bits) can be sourced from the E1-TRAN National Bits Codeword registers as 4-bit codewords aligned to the submultiframe. Alternatively, the Sa-bits may individually carry data links sourced from the internal HDLC controller, or may be passed transparently from the ED[x] input. 9.13 Transmit Per-Channel Serial Controller (TPSC) The Transmit Per-Channel Serial Controller allows data and signaling trunk conditioning or idle code to be applied on the transmit DS-1 stream on a perchannel basis. It also allows per-channel control of zero code suppression, data inversion, channel loopback (from the ingress stream), channel insertion, and the detection or generation of pseudo-random patterns. The TPSC interfaces directly to the E1-TRAN and T1-XBAS block and provides serial streams for signaling control, idle code data and egress data control. 9.14 Signaling Aligner (SIGA) The Signaling Aligner is a block that is only applicable in T1 operating modes. When enabled, the Signaling Aligner is positioned in the egress path before the T1-XBAS. Its purpose is to ensure that if the signaling on ESIG[x] is changed in the middle of a superframe, the XBAS completes transmitting the A,B,C, and D
PROPRIETARY AND CONFIDENTIAL
83
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
bits for the current superframe before switching to the new values. This permits signaling integrity to be preserved independent of the superframe alignment of the T1-XBAS or the signaling data source. 9.15 Bit Oriented Code Generator (XBOC) The Bit Oriented Code Generator function is provided by the XBOC block. This block transmits 63 of the possible 64 bit oriented codes in the Facility Data Link (FDL) channel in ESF framing format, as defined in ANSI T1.403-1989 or in the DS3 C-bit parity Far-End Alarm and Control (FEAC) channel. The 64th code (111111) is similar to the HDLC Flag sequence and is used in the XBOC to disable transmission of any bit oriented codes. When transmission is disabled the FDL or FEAC channel is set to all ones. Bit oriented codes are transmitted on the T1 Facility Data Link or DS3 Far-End Alarm and Control channel as a 16-bit sequence consisting of 8 ones, a zero, 6 code bits, and a trailing zero (111111110xxxxxx0) which is repeated as long as the code is not 111111. When driving the T1 facility data link the transmitted bit oriented codes have priority over any data transmitted except for ESF Yellow Alarm. The code to be transmitted is programmed by writing to the XBOC code registers when it is held until the last code has been transmitted at least 10 times. An interrupt or polling mechanism is used to determine when the most recent code written the XBOC register is being transmitted and a new code can be accepted. 9.16 HDLC Transmitters (TDPR) The HDLC Transmitter (TDPR) provides a serial data link for the 4 kHz ESF facility data link, E1 Sa-bit data link, the DS3 C-bit parity path maintenance data link or a specified channel within a T1 or E1 stream. The TDPR is used under microprocessor control to transmit HDLC data frames. It performs all of the data serialization, CRC generation, zero-bit stuffing, as well as flag, and abort sequence insertion. Upon completion of the message, a CRC-CCITT frame check sequence (FCS) may be appended, followed by flags. If the TDPR transmit data FIFO underflows, an abort sequence is automatically transmitted. When enabled, the TDPR continuously transmits the flag sequence (01111110) until data is ready to be transmitted. Data bytes to be transmitted are written into the Transmit Data Register. The TDPR performs a parallel-to-serial conversion of each data byte before transmitting it. The default procedure provides automatic transmission of data once a complete packet is written. All complete packets of data will be transmitted. After the last data byte of a packet, the CRC word (if CRC insertion has been enabled) and a
PROPRIETARY AND CONFIDENTIAL
84
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
flag, or just a flag (if CRC insertion has not been enabled) is transmitted. The TDPR then returns to the transmission of flag characters until the next packet is available for transmission. While working in this mode, the user must only be careful to avoid overfilling the FIFO; underruns cannot occur unless the packet is greater than 128 bytes long. The TDPR will force transmission if the FIFO is filled up regardless of whether or not the packet has been completely written into the FIFO. The second procedure transmits data only when the FIFO depth has reached a user configured upper threshold. The TDPR will continue to transmit data until the FIFO depth has fallen below the upper threshold and the transmission of the last packet with data above the upper threshold has completed. In this mode, the user must be careful to avoid overruns and underruns. An interrupt can be generated once the FIFO depth has fallen below a user configured lower threshold as an indicator for the user to write more data. Interrupts can also be generated if the FIFO underflows while transmitting a packet, when the FIFO falls below a lower threshold, when the FIFO is full, or if the FIFO is overrun. If there are more than five consecutive ones in the raw transmit data or in the CRC data, a zero is stuffed into the serial data output. This prevents the unintentional transmission of flag or abort sequences. Abort characters can be continuously transmitted at any time by setting the ABT bit in the TDPR Configuration register. During packet transmission, an underrun situation can occur if data is not written to the TDPR Transmit Data register before the previous byte has been depleted. In this case, an abort sequence is transmitted, and the controlling processor is notified via the UDRI interrupt. 9.17 T1 Automatic Performance Report Generation (APRM) In compliance with the ANSI T1.231, T1.403 and T1.408 standards, a performance report is generated each second for T1 ESF applications. The report conforms to the HDLC protocol and is inserted into the ESF facility data link. The performance report can only be transmitted if the TDPR is configured to insert the ESF Facility Data Link and the PREN bit of the TDPR Configuration register is logic 1. The performance report takes precedence over incompletely written packets, but it does not pre-empt packets already being transmitted. See the Operation section for details on the performance report encoding.
PROPRIETARY AND CONFIDENTIAL
85
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
9.18 Receive and Transmit Digital Jitter Attenuator (RJAT, TJAT) The Digital Jitter Attenuation function is provided by the DJAT blocks. Each framer in the TEMUX contains two separate jitter attenuators, one between the receive demultiplexed or demapped T1 or E1 link and the ingress interface (RJAT) and the other between the egress interface and the transmit T1 or E1 link to be multiplexed into DS3 or mapped into SONET (TJAT). Each DJAT block receives jittered data and stores the stream in a FIFO timed to the associated receive jittered clock. The jitter attenuated data emerges from the FIFO timed to the jitter attenuated clock. In the RJAT, the jitter attenuated clock (ICLK[x]) is referenced to the demultiplexed or demapped tributary receive clock. In the TJAT, the jitter attenuated transmit tributary clock feeding the M13 multiplexer or SONET/SDH mapper may be referenced to either CTCLK, CECLK, or the tributary receive clock. In T1 mode each jitter attenuator generates its output clock by adaptively dividing the 37.056 MHz XCLK signal according to the phase difference between the jitter attenuated clock and the input reference clock. Jitter fluctuations in the phase of the reference clock are attenuated by the phase-locked loop within each DJAT so that the frequency of the jitter attenuated clock is equal to the average frequency of the reference. To best fit the jitter attenuation transfer function recommended by TR 62411, phase fluctuations with a jitter frequency above 6.6 Hz are attenuated by 6 dB per octave of jitter frequency. Wandering phase fluctuations with frequencies below 6.6 Hz are tracked by the jitter attenuated clock. The jitter attenuated clock (ICLK[x] for the RJAT and transmit clock for the TJAT) are used to read data out of the FIFO. In E1 mode each jitter attenuator generates the jitter-free 2.048 MHz output clock by adaptively dividing the 49.152 MHz XCLK signal according to the phase difference between the jitter attenuated clock and input reference clock. Fluctuations in the phase of the input data clock are attenuated by the phaselocked loop within DJAT so that the frequency of the jitter attenuated clock is equal to the average frequency of the input data clock. Phase fluctuations with a jitter frequency above 8.8 Hz are attenuated by 6 dB per octave of jitter frequency. Wandering phase fluctuations with frequencies below 8.8 Hz are tracked by the jitter attenuated clock. To provide a smooth flow of data out of DJAT, the jitter attenuated clock is used to read data out of the FIFO. The TJAT and RJAT have programmable divisors in order to generate the jitter attenuated clock from the various reference sources. The divisors are set using the TJAT and RJAT Jitter Attenuator Divider N1 and N2 registers. The following formula must be met in order to select the values of N1 and N2: Fin/(N1 + 1) = Fout/(N2 + 1)
PROPRIETARY AND CONFIDENTIAL
86
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
where Fin is the input reference clock frequency and Fout is the output jitter attenuated clock frequency. The values on N1 and N2 can range between 1 and 256. Fin ranges from 8KHz to 2.048MHz in 8KHz increments. If the FIFO read pointer comes within one bit of the write pointer, DJAT will track the jitter of the input clock. This permits the phase jitter to pass through unattenuated, inhibiting the loss of data. Jitter Characteristics Each DJAT Block provides excellent jitter tolerance and jitter attenuation while generating minimal residual jitter. In T1 mode each DJAT can accommodate up to 28 UIpp of input jitter at jitter frequencies above 6 Hz. For jitter frequencies below 6 Hz, more correctly called wander, the tolerance increases 20 dB per decade. In E1 mode each DJAT can accommodate up to 35 UIpp of input jitter at jitter frequencies above 9 Hz. For jitter frequencies below 9 Hz, more correctly called wander, the tolerance increases 20 dB per decade. In most applications the each DJAT Block will limit jitter tolerance at lower jitter frequencies only. For high frequency jitter, above 10 kHz for example, other factors such as clock and data recovery circuitry may limit jitter tolerance and must be considered. For low frequency wander, below 10 Hz for example, other factors such as slip buffer hysteresis may limit wander tolerance and must be considered. The DJAT blocks meet the stringent low frequency jitter tolerance requirements of AT&T TR 62411, ITU-T Recommendation G.823 and thus allow compliance with this standard and the other less stringent jitter tolerance standards cited in the references. The DJAT exhibits negligible jitter gain for jitter frequencies below 6.6 Hz, and attenuates jitter at frequencies above 6.6 Hz by 20 dB per decade in T1 mode. It exhibits negligible jitter gain for jitter frequencies below 8.8 Hz, and attenuates jitter at frequencies above 8.8 Hz by 20 dB per decade in E1 mode. In most applications the DJAT Blocks will determine jitter attenuation for higher jitter frequencies only. Wander, below 10 Hz for example, will essentially be passed unattenuated through DJAT. Jitter, above 10 Hz for example, will be attenuated as specified, however, outgoing jitter may be dominated by the generated residual jitter in cases where incoming jitter is insignificant. This generated residual jitter is directly related to the use of 24X (37.056 MHz or 49.152 MHz) digital phase locked loop for transmit clock generation. DJAT meets the jitter transfer requirements of AT&T TR 62411. The DJAT allows the implied T1 jitter attenuation requirements for a TE or NT1 given in ANSI Standard T1.408, and the implied jitter attenuation requirements for a type II customer interface given in ANSI T1.403 to be met. The DJAT meets the E1 jitter attenuation requirements of the ITU-T Recommendations G.737, G.738, G.739 and G.742.
PROPRIETARY AND CONFIDENTIAL
87
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Jitter Tolerance Jitter tolerance is the maximum input phase jitter at a given jitter frequency that a device can accept without exceeding its linear operating range, or corrupting data. For T1 modes the DJAT input jitter tolerance is 29 Unit Intervals peak-topeak (UIpp) with a worst case frequency offset of 354 Hz. For E1 modes the input jitter tolerance is 35 Unit Intervals peak-to-peak (UIpp) with a worst case frequency offset of 308 Hz. In either mode jitter tolerance is 48 UIpp with no frequency offset. The frequency offset is the difference between the frequency of XCLK divided by 24 and that of the input data clock. Figure 9 - DJAT Jitter Tolerance T1 Modes 100 28 Jitter Amplitude, UIpp 10
acceptable DJAT minimum tolerance
29
1.0
unacceptable
0.2
0.1
0.01
1
4.9 10
100
0.3k
1k
10k
100k
Jitter Frequency, Hz
PROPRIETARY AND CONFIDENTIAL
88
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Figure 10
- DJAT Jitter Tolerance E1 Modes
The accuracy of the XCLK frequency and that of the reference clock used to generate the jitter attenuated clock have an effect on the minimum jitter tolerance. Given that the DJAT PLL reference clock accuracy can be 200 Hz from 1.544 MHz or be 103 Hz from 2.048 MHz, and that the XCLK input accuracy can be 100 ppm from 37.056 MHz or 100 ppm from 49.152 MHz, the minimum jitter tolerance for various differences between the frequency of PLL reference clock and XCLK / 24 are shown in Figure 11 and Figure 12. An XCLK input accuracy of 100 ppm is only acceptable if an accurate line rate reference is provided. If TJAT is left to free-run without a reference, or referenced to a derivative of XCLK, then XCLK accuracy must be 32 ppm.
PROPRIETARY AND CONFIDENTIAL
89
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Figure 11
- DJAT Minimum Jitter Tolerance vs. XCLK Accuracy T1 Modes
40 36 35
DJAT Minimum Jitter Tolerance UI pp
34
30
29
Max frequency offset (PLL Ref to XCLK)
25 100 XCLK Accuracy
200 0
250 32
300
354 100
Hz ppm
Figure 12
- DJAT Minimum Jitter Tolerance vs. XCLK Accuracy E1 Modes
45 42.4 40 DJAT Minimum Jitter Tolerance UI pp 39 34.9
35
Max frequency offset (PLL Ref to XCLK) XCLK Accuracy
Jitter Transfer
30 100 0
200 49
300 308 100
Hz ppm
The output jitter in T1 mode for jitter frequencies from 0 to 6.6 Hz is no more than 0.1 dB greater than the input jitter, excluding the residual jitter. Jitter
PROPRIETARY AND CONFIDENTIAL
90
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
frequencies above 6.6 Hz are attenuated at a level of 6 dB per octave, as shown in Figure 13.
Figure 13 - DJAT Jitter Transfer T1 Modes
0 -10 -20 -30 -40 -50
62411 min DJAT response 62411 max 43802 max
Jitter Gain (dB)
1 6.6
10
100 1k Jitter Frequency, Hz
10k
The output jitter in E1 mode for jitter frequencies from 0 to 8.8 Hz is no more than 0.1 dB greater than the input jitter, excluding the residual jitter. Jitter frequencies above 8.8 Hz are attenuated at a level of 6 dB per octave, as shown in Figure 14.
PROPRIETARY AND CONFIDENTIAL
91
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Figure 14
- DJAT Jitter Transfer E1 Modes
Frequency Range
In the non-attenuating mode for T1 rates, that is, when the FIFO is within one UI of overrunning or under running, the tracking range is 1.48 to 1.608 MHz. The guaranteed linear operating range for the jittered input clock is 1.544 MHz 200 Hz with worst case jitter (29 UIpp) and maximum XCLK frequency offset ( 100 ppm). The nominal range is 1.544 MHz 963 Hz with no jitter or XCLK frequency offset. In the non-attenuating mode for E1 rates the tracking range is 1.963 to 2.133 MHz. The guaranteed linear operating range for the jittered input clock is 2.048 MHz 1278 Hz with worst case jitter (42 UIpp) and maximum XCLK frequency offset ( 100 ppm).
9.19 Timing Options (TOPS)
The Timing Options block provides a means of selecting the source of the internal input clock to the TJAT block, the reference clock for the TJAT digital PLL, and the clock source used to derive the transmit clock to the M13 mux or SONET/SDH mapper.
PROPRIETARY AND CONFIDENTIAL
92
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
9.20 Pseudo Random Binary Sequence Generation and Detection (PRBS)
The Pseudo Random Binary Sequence Generator/Detector (PRBS) block is a software selectable PRBS generator and checker for 211-1, 215-1 or 220-1 PRBS polynomials for use in the T1 and E1 links. PRBS patterns may be generated in either the transmit or receive directions, and detected in the opposite direction. The PRBS block can perform an auto synchronization to the expected PRBS pattern and accumulates the total number of bit errors in two 24-bit counters. The error count accumulates over the interval defined by to the Global PMON Update Register. When an accumulation is forced, the holding register is updated, and the counter reset to begin accumulating for the next interval. The counter is reset in such a way that no events are missed. The data is then available in the Error Count registers until the next accumulation.
9.21 Pseudo Random Pattern Generation and Detection (PRGD)
The Pseudo Random Pattern Generator/Detector (PRGD) block is a software programmable test pattern generator, receiver, and analyzer for the DS3 payload. Patterns may be generated in the transmit direction, and detected in the receive direction. Two types of ITU-T O.151 compliant test patterns are provided : pseudo-random and repetitive. The PRGD can be programmed to generate any pseudo-random pattern with length up to 232-1 bits or any user programmable bit pattern from 1 to 32 bits in length. In addition, the PRGD can insert single bit errors or a bit error rate between 10-1 to 10-7. The PRGD can be programmed to check for the generated pseudo random pattern. The PRGD can perform an auto synchronization to the expected pattern and accumulates the total number of bits received and the total number of bit errors in two 32-bit counters. The counters accumulate either over intervals defined by writes to the Pattern Detector registers, upon writes to the Global PMON Update Register or automatically once a second. When an accumulation is forced, the holding registers are updated, and the counters reset to begin accumulating for the next interval. The counters are reset in such a way that no events are missed. The data is then available in the holding registers until the next accumulation.
9.22 DS3 Framer (DS3-FRMR)
The DS3 Framer (DS3-FRMR) Block integrates circuitry required for decoding a B3ZS-encoded signal and framing to the resulting DS3 bit stream. The DS3-FRMR is directly compatible with the M23 and C-bit parity DS3 applications.
PROPRIETARY AND CONFIDENTIAL
93
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
The DS3-FRMR decodes a B3ZS-encoded signal and provides indications of line code violations. The B3ZS decoding algorithm and the LCV definition can be independently chosen through software. A loss of signal (LOS) defect is also detected for B3ZS encoded streams. LOS is declared when inputs RPOS and RNEG contain zeros for 175 consecutive RCLK cycles. LOS is removed when the ones density on RPOS and/or RNEG is greater than 33% for 175 1 RCLK cycles. The framing algorithm examines five F-bit candidates simultaneously. When at least one discrepancy has occurred in each candidate, the algorithm examines the next set of five candidates. When a single F-bit candidate remains in a set, the first bit in the supposed M-subframe is examined for the M-frame alignment signal (i.e., the M-bits, M1, M2, and M3 are following the 010 pattern). Framing is declared, and out-of-frame is removed, if the M-bits are correct for three consecutive M-frames while no discrepancies have occurred in the F-bits. During the examination of the M-bits, the X-bits and P-bits are ignored. The algorithm gives a maximum average reframe time of 1.5 ms. While the DS3-FRMR is synchronized to the DS3 M-frame, the F-bit and M-bit positions in the DS3 stream are examined. An out-of-frame defect is detected when 3 F-bit errors out of 8 or 16 consecutive F-bits are observed (as selected by the M3O8 bit in the DS3 FRMR Configuration Register), or when one or more M-bit errors are detected in 3 out of 4 consecutive M-frames. The M-bit error criteria for OOF can be disabled by the MBDIS bit in the DS3 Framer Configuration register. The 3 out of 8 consecutive F-bits out-of-frame ratio provides more robust operation, in the presence of a high bit error rate, than the 3 out of 16 consecutive F-bits ratio. Either out-of-frame criteria allows an out-offrame defect to be detected quickly when the M-subframe alignment patterns or, optionally, when the M-frame alignment pattern is lost. Also while in-frame, line code violations, M-bit or F-bit framing bit errors, and Pbit parity errors are indicated. When C-bit parity mode is enabled, both C-bit parity errors and far end block errors are indicated. These error indications, as well as the line code violation and excessive zeros indication, are accumulated over 1 second intervals with the Performance Monitor (PMON). Note that the framer is an off-line framer, indicating both OOF and COFA events. Even if an OOF is indicated, the framer will continue indicating performance monitoring information based on the previous frame alignment. Three DS3 maintenance signals (a RED alarm condition, the alarm indication signal, and the idle signal) are detected by the DS3-FRMR. The maintenance detection algorithm employs a simple integrator with a 1:1 slope that is based on the occurrence of "valid" M-frame intervals. For the RED alarm, an M-frame is said to be a "valid" interval if it contains a RED defect, defined as an occurrence of an OOF or LOS event during that M-frame. For AIS and IDLE, an M-frame
PROPRIETARY AND CONFIDENTIAL
94
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
interval is "valid" if it contains AIS or IDLE, defined as the occurrence of less than 15 discrepancies in the expected signal pattern (1010... for AIS, 1100... for IDLE) while valid frame alignment is maintained. This discrepancy threshold ensures the detection algorithms operate in the presence of a 10-3 bit error rate. For AIS, the expected pattern may be selected to be: the framed "1010" signal; the framed arbitrary DS3 signal and the C-bits all zero; the framed "1010" signal and the C-bits all zero; the framed all-ones signal (with overhead bits ignored); or the unframed all-ones signal (with overhead bits equal to ones). Each "valid" Mframe causes an associated integration counter to increment; "invalid" M-frames cause a decrement. With the "slow" detection option, RED, AIS, or IDLE are declared when the respective counter saturates at 127, which results in a detection time of 13.5 ms. With the "fast" detection option, RED, AIS, or IDLE are declared when the respective counter saturates at 21, which results in a detection time of 2.23 ms (i.e., 1.5 times the maximum average reframe time). RED, AIS, or IDLE are removed when the respective counter decrements to 0. DS3 Loss of Frame detection is provided as recommended by ITU-T G.783 with programmable integration periods of 1ms, 2ms, or 3ms. While integrating up to assert LOF, the counter will integrate up when the framer asserts an Out of Frame condition and integrates down when the framer de-asserts the Out of Frame condition. Once an LOF is asserted, the framer must not assert OOF for the entire integration period before LOF is deasserted. Valid X-bits are extracted by the DS3-FRMR to provide indication of far end receive failure (FERF). A FERF defect is detected if the extracted X-bits are equal and are logic 0 (X1=X2=0); the defect is removed if the extracted X-bits are equal and are logic 1 (X1=X2=1). If the X-bits are not equal, the FERF status remains in its previous state. The extracted FERF status is buffered for 2 Mframes before being reported within the DS3 FRMR Status register. This buffer ensures a better than 99.99% chance of freezing the FERF status on a correct value during the occurrence of an out of frame. When the C-bit parity application is enabled, both the far end alarm and control (FEAC) channel and the path maintenance data link are extracted. Codes in the FEAC channel are detected by the Bit Oriented Code Detector (RBOC). HDLC messages in the Path Maintenance Data Link are received by the Data Link Receiver (RDLC). The DS3-FRMR can be enabled to automatically assert the RAI indication in the outgoing transmit stream upon detection of any combination of LOS, OOF or RED, or AIS. The DS3-FRMR can also be enabled to automatically insert C-bit Parity FEBE upon detection of receive C-bit parity error. The DS3-FRMR may be configured to generate interrupts on error events or status changes. All sources of interrupts can be masked or acknowledged via
PROPRIETARY AND CONFIDENTIAL
95
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
internal registers. Internal registers are also used to configure the DS3-FRMR. Access to these registers is via a generic microprocessor bus.
9.23 Performance Monitor Accumulator (DS3-PMON)
The Performance Monitor (PMON) Block interfaces directly with the DS3 Framer (DS3-FRMR). Saturating counters are used to accumulate:
* * * * * *
line code violation (LCV) events parity error (PERR) events path parity error (CPERR) events far end block error (FEBE) events excess zeros (EXZS) framing bit error (FERR) events
Due to the off-line nature of the DS3 Framer, PMON continues to accumulate performance meters even while the DS3-FRMR has declared OOF. When an accumulation interval is signaled by a write to the PMON register address space, the PMON transfers the current counter values into microprocessor accessible holding registers and resets the counters to begin accumulating error events for the next interval. The counters are reset in such a manner that error events occurring during the reset period are not missed. When counter data is transferred into the holding registers, an interrupt is generated, providing the interrupt is enabled. If the holding registers have not been read since the last interrupt, an overrun status bit is set. In addition, a register is provided to indicate changes in the PMON counters since the last accumulation interval. Whenever counter data is transferred into the holding registers, an interrupt is generated, providing the interrupt is enabled. If the holding registers have not been read since the last interrupt, an overrun status bit is set.
9.24 DS3 Transmitter (DS3-TRAN)
The DS3 Transmitter (DS3-TRAN) Block integrates circuitry required to insert the overhead bits into a DS3 bit stream and produce a B3ZS-encoded signal. The T3-TRAN is directly compatible with the M23 and C-bit parity DS3 formats.
PROPRIETARY AND CONFIDENTIAL
96
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
When configured for the C-bit parity application, all overhead bits are inserted. When configured for the M23 application, all overhead bits except the stuff control bits (the C-bits) are inserted; the C-bits are inserted by the upstream MX23 TSB. Status signals such as far end receive failure (FERF), the alarm indication signal, and the idle signal can be inserted when their transmission is enabled by internal register bits. FERF can also be automatically inserted on detection of any combination of LOS, OOF or RED, or AIS by the DS3-FRMR. A valid pair of P-bits is automatically calculated and inserted by the DS3-TRAN. When C-bit parity mode is selected, the path parity bits, and far end block error (FEBE) indications are automatically inserted. When enabled for C-bit parity operation, the FEAC channel is sourced by the XBOC bit-oriented code transmitter. The path maintenance data link messages are sourced by the TDPR data link transmitter. The DS3-TRAN supports diagnostic modes in which it inserts parity or path parity errors, F-bit framing errors, M-bit framing errors, invalid X or P-bits, line code violations, or all-zeros.
9.25 M23 Multiplexer (MX23)
The M23 Multiplexer (MX23) integrates circuitry required to asynchronously multiplex and demultiplex seven DS2 streams into, and out of, an M23 or C-bit Parity formatted DS3 serial stream. When multiplexing seven DS2 streams into an M23 formatted DS3 stream, the MX23 TSB performs rate adaptation to the DS3 by integral FIFO buffers, controlled by timing circuitry. The C-bits are also generated and inserted by the timing circuitry. Software control is provided to transmit DS2 AIS and DS2 payload loopback requests. The loopback request is coded by inverting one of the three C-bits (the default option is compatible with ANSI T1.107a Section 8.2.1 and TR-TSY-000009 Section 3.7). The TSB also supports generation of a C-bit Parity formatted DS3 stream by providing an internally generated DS2 rate clock corresponding to a 100% stuffing ratio. Integrated M13 applications are supported by providing an internally generated DS2 rate clock corresponding to a 39.1% stuffing ratio. When demultiplexing seven DS2 streams from an M23 formatted DS3, the MX23 performs bit destuffing via interpretation of the C-bits. The MX23 also detects and indicates DS2 payload loopback requests encoded in the C-bits. As per ANSI T1.107a Section 8.2.1 and TR-TSY-000009 Section 3.7, the loopback command is identified as C3 being the inverse of C1 and C2. Because TR-TSY-
PROPRIETARY AND CONFIDENTIAL
97
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
000233 Section 5.3.14.1 recommends compatibility with non-compliant existing equipment, the two other loopback command possibilities are also supported. As per TR-TSY-000009 Section 3.7, the loopback request must be present for five successive M-frames before declaration of detection. Removal of the loopback request is declared when it has been absent for five successive M-frames. DS2 payload loopback can be activated or deactivated under software control. During payload loopback the DS2 stream being looped back still continues unaffected in the demultiplex direction to the DS2 Framer. All seven demultiplexed DS2 streams can also be replaced with AIS on an individual basis under register control or they can be configured to be replaced automatically on detection of out of frame, loss of signal, RED alarm or alarm indication signal.
9.26 DS2 Framer (DS2-FRMR)
The FRMR DS2 Framer integrates circuitry required for framing to a DS2 bit stream and is directly compatible with the M12 DS2 application. The FRMR can also be configured to frame to a G.747 bit stream. The DS2 FRMR frames to a DS2 signal with a maximum average reframe time of less than 7 ms and frames to a G.747 signal with a maximum average reframe time of 1 ms. In DS2 mode, both the F-bits and M-bits must be correct for a significant period of time before frame alignment is declared. In G.747 mode, frame alignment is declared if the candidate frame alignment signal has been correct for 3 consecutive frames (in accordance with CCITT Rec. G.747 Section 4). Once in frame, the DS2 FRMR provides indications of the M-frame and Msubframe boundaries, and identifies the overhead bit positions in the incoming DS2 signal or provides indications of the frame boundaries and overhead bit positions in the incoming G.747 signal. Depending on configuration, declaration of DS2 out-of-frame occurs when 2 out of 4 or 2 out of 5 consecutive F-bits are in error (These two ratios are recommended in TR-TSY-000009 Section 4.1.2) or when one or more M-bit errors are detected in 3 out of 4 consecutive M-frames. The M-bit error criteria for OOF can be disabled via the MBDIS bit in the DS2 Framer configuration register. In G.747 mode, out-of-frame is declared when four consecutive frame alignment signals are incorrectly received (in accordance with CCITT Rec. G.747 Section 4). Note that the DS2 framer is an off-line framer, indicating both OFF and COFA. Error events continue to be indicated even when the FRMR is indicating OOF, based on the previous frame alignment. The RED alarm and alarm indication signal are detected by the DS2 FRMR in 9.9 ms for DS2 format and in 6.9 ms for G.747 format. The framer employs a simple integration algorithm (with a 1:1 slope) that is based on the occurrence of "valid" DS2 M-frame or G.747 frame intervals. For the RED alarm, a DS2 M-
PROPRIETARY AND CONFIDENTIAL
98
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
frame (or G.747 frame, depending upon the framing format selected) is said to be a "valid" interval if it contains a RED defect, defined as the occurrence of an OOF event during that M-frame (or G.747 frame). For AIS, a DS2 M-frame (or G.747 frame) is said to be a "valid" interval if it contains AIS, defined as the occurrence of less than 9 zeros while the framer is out of frame during that Mframe (or G.747 frame). The discrepancy threshold ensures the detection algorithm operates in the presence of bit error rates of up to 10-3. Each "valid" DS2 M-frame (or G.747 frame) causes an integration counter to increment; "nonvalid" DS2 M-frame (or G.747 frame) intervals cause a decrement. RED or AIS is declared if the associated integrator count saturates at 53, resulting in a detection time of 9.9 ms for DS2 and 6.9 ms for G.747. RED or AIS declaration is deasserted when the associated count decrements to 0. The DS2 X-bit or G.747 remote alarm indication (RAI) bit is extracted by the DS2 FRMR to provide an indication of far end receive failure. The FERF status is set to the current X/RAI state only if the two successive X/RAI bits were in the same state. The extracted FERF status is buffered for 6 DS2 M-frames or 6 G.747 frames before being reported within the DS2 FRMR Status register. This buffer ensures a virtually 100% probability of freezing the FERF status in a valid state during an out of frame occurrence in DS2 mode, and ensures a better than 99.9% probability of freezing the valid status during an OOF occurrence in G.747 mode. When an OOF occurs, the FERF value is held at the state contained in the last buffer location corresponding to the previous sixth M-frame or G.747 frame. This location is not updated until the OOF condition is deasserted. Meanwhile, the last four of the remaining five buffer locations are loaded with the frozen FERF state while the first buffer location corresponding to the current Mframe/ G.747 frame is continually updated every M-frame/G.747 frame based on the above FERF definition. Once correct frame alignment has been found and OOF is deasserted, the first buffer location will contain a valid FERF status and the remaining five buffer locations are enabled to be updated every M-frame or G.747 frame. DS2 M-bit and F-bit framing errors are indicated as are G.747 framing word errors (or bit errors) and G.747 parity errors. These error indications are accumulated for performance monitoring purposes in internal, microprocessor readable counters. The performance monitoring accumulators continue to count error indication even while the framer is indicating OOF. The DS2 FRMR may be configured to generate interrupts on error events or status changes. All sources of interrupts can be masked or acknowledged via internal registers. Internal registers are also used to configure the DS2 FRMR.
PROPRIETARY AND CONFIDENTIAL
99
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
9.27 M12 Multiplexer (MX12)
The MX12 M12 Multiplexer integrates circuitry required to asynchronously multiplex and demultiplex four DS1 streams into, and out of, an M12 formatted DS2 serial stream (as defined in ANSI T1.107 Section 7) and to support asynchronous multiplexing and demultiplexing of three 2048 kbit/s into and out of a G.747 formatted 6312 kbit/s high speed signal (as defined in CCITT Rec. G.747). When multiplexing four DS1 streams into an M12 formatted DS2 stream, the MX12 TSB performs logical inversion on the second and fourth tributary streams. Rate adaptation to the DS2 is performed by integral FIFO buffers, controlled by timing circuitry. The FIFO buffers accommodate in excess of 5.0 UIpp of sinusoidal jitter on the DS1 clocks for all jitter frequencies. X, F, M, and C bits are also generated and inserted by the timing circuitry. Software control is provided to transmit Far End Receive Failure (FERF) indications, DS2 AIS, and DS1 payload loopback requests. The loopback request is coded by inverting one of the three C-bits (the default option is compatible with ANSI T1.107a Section 8.2.1 and TR-TSY-000009 Section 3.7).Two diagnostic options are provided to invert the transmitted F or M bits. When demultiplexing four DS1 streams from an M12 formatted DS2, the MX12 performs bit destuffing via interpretation of the C-bits. The MX12 also detects and indicates DS1 payload loopback requests encoded in the C-bits. As per ANSI T1.107 Section 7.2.1.1 and TR-TSY-000009 Section 3.7, the loopback command is identified as C3 being the inverse of C1 and C2. Because TR-TSY000233 Section 5.3.14.1 recommends compatibility with non-compliant existing equipment, the two other loopback command possibilities are also supported. As per TR-TSY-000009 Section 3.7, the loopback request must be present for five successive M-frames before declaration of detection. Removal of the loopback request is declared when it has been absent for five successive M-frames. DS1 payload loopback can be activated or deactivated under software control. During payload loopback the DS1 stream being looped back still continues unaffected in the demultiplex direction. The second and fourth demultiplexed DS1 streams are logically inverted, and all four demultiplexed DS1 streams can be replaced with AIS on an individual basis. Similar functionality supports CCITT Recommendation G.747. The FIFO is still required for rate adaptation. The frame alignment signal and parity bit are generated and inserted by the timing circuitry. Software control is provided to transmit Remote Alarm Indication (RAI), high speed signal AIS, and the reserved bit. A diagnostic option is provided to invert the transmitted frame alignment signal and parity bit.
PROPRIETARY AND CONFIDENTIAL
100
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
When demultiplexing three 2048 kbit/s streams from a G.747 formatted 6312 kbit/s stream, the MX12 performs bit destuffing via interpretation of the C-bits. Tributary payload loopback can be activated or deactivated under software control. Although no remote loopback request has been defined for G.747, inversion of the third C-bit triggers a loopback request detection indication in anticipation of Recommendation G.747 refinement. All three demultiplexed 2048 kbit/s streams can be replaced with AIS on an individual basis.
9.28 Tributary Payload Processor (VTPP)
The tributary payload processor (VTPP) processes the virtual tributaries within an STS-1, AU3, or TUG3. The VTPP can be configured to process either VT1.5s or VT2s within an STS-1 or either TU11s or TU12s within an AU3 or TUG3. The number of tributaries managed by each VTPP ranges from 21 (when configured to process all VT2s or equivalently all TU12s) to 28 (when configured to process all VT1.5s or equivalently all TU11s). The Tributary payload processor is used in both the ingress and egress data paths. In the egress direction the pointer interpreter section of the VTPP can be bypassed on a per tributary basis to allow for pointer generator in the absence of valid pointers which is necessary when mapping floating transparent virtual tributaries from the SBI bus.
9.28.1 Clock Generator
The clock generator derives various clocks from the 19.44 MHz system clock and distributes them to other blocks within the tributary payload processor. The overall design is totally synchronous, with processing occurring at a 6.48 MHz rate in each tributary payload processor.
9.28.2 Incoming Timing Generator
The incoming timing generator identifies the incoming tributary being processed at any given point in time. Based on the configuration of the VTPP (it can process various mixes of tributary types), the incoming timing generator extracts the STS-1 SPE, VC3, or a single TUG3 from a VC4, and identifies the bytes within these envelopes that correspond to various types of overhead and those that carry specific tributaries to be processed. The H4 byte is identified for the incoming multiframe detector so that it can determine the incoming tributary multiframe boundaries. The identification of specific tributaries allows the pointer interpreter to be time-sliced across the mix of tributaries present in the incoming data stream. The identification of the V1-V3 bytes of VTs, or TUs allows the pointer interpreter to function.
PROPRIETARY AND CONFIDENTIAL
101
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
9.28.3 Incoming Multiframe Detector
The multiframe alignment sequence in the path overhead H4 byte is monitored for the bit patterns of 00, 01, 10, 11 in the two least significant bits. If an unexpected value is detected, the primary multiframe will be kept, and a second multiframe process will, in parallel, check for a phase shift. The primary process will enter out of multiframe state (OOM). A new multiframe alignment is chosen, and OOM state is exited when four consecutive correct multiframe patterns are detected. Loss of multiframe (LOM) is declared after residing in the OOM state at the ninth H4 byte without re-alignment. In counting to nine, the out of sequence H4 byte that triggered the transition to the OOM state is counted as the first. A new multiframe alignment is chosen, and LOM state is exited when four consecutive correct multiframe patterns are detected. Changes in multiframe alignments are detected and reported.
9.28.4 Pointer Interpreter
The pointer interpreter is a time-sliced state machine that can process up to 28 independent tributaries. The state vector is saved in RAM as directed by the incoming timing generator. The pointer interpreter processes the incoming tributary pointers such that all bytes within the tributary synchronous payload envelope can be identified and written into the unique payload first-in first-out buffer for the tributary in question. A marker that tags the V5 byte is passed through the payload buffer. The incoming timing generator directs the pointer interpreter to the correct payload buffer for the tributary being processed. The pointer interpreter processes the incoming pointers (V1/V2) as specified in the references. The pointer value is used to determine the location of the tributary path overhead byte (V5) in the incoming TUG3 or STS-1 (AU3) stream.
9.28.5 Payload Buffer
The payload buffer is a bank of FIFO buffers. It is synchronous in operation and is based on a time-sliced RAM. The three 19.44 MHz clock cycles in each 6.48 MHz period are shared between the read and write operations. The pointer interpreter writes tributary payload data and the V5 tag into the payload buffer. A 16 byte FIFO buffer is provided for each of the (up to 28) tributaries. Address information is also passed through the payload buffer to allow FIFO fill status to be determined by the pointer generator.
PROPRIETARY AND CONFIDENTIAL
102
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
9.28.6 Outgoing Timing Generator
The outgoing timing generator identifies the outgoing tributary byte being processed. Based on the configuration of the VTPP, the outgoing timing generator effectively constructs the STS-1 SPE, VC3, or VC4, and identifies the bytes within these envelopes that correspond to various types of overhead and bytes that carry specific tributaries. The identification of specific tributaries allows the pointer generator to be time-sliced across the mix of tributaries to be sourced in the outgoing data stream. The identification of the V1-V3 bytes of VTs, or TUs allows the pointer generator to function. The sequence of H4 bytes is generated by each tributary payload processor and inserted into the outgoing administrative units. The six most significant bits of H4 are set to logic 1. The sequence of the remaining two H4 bits is determined by the multiframe alignment.
9.28.7 Pointer Generator
The pointer generator block generates the tributary pointers (V1/V2) as specified in the references. The pointer value is used to determine the location of the tributary path overhead byte (V5) on the outgoing stream. The pointer generator is a time-sliced state machine that can process up to 28 independent tributaries. The state vector is saved in RAM at the address associated with the current tributary. The pointer generator fills the outgoing tributary synchronous payload envelopes with bytes read from the associated FIFO in the payload buffer for the current tributary. The pointer generator creates pointers in the V1-V3 bytes of the outgoing data stream. The marker that tags the V5 byte that is passed through the payload buffer is used to align the pointer. The outgoing timing generator directs the pointer generator to the FIFO in the payload buffer that is associated with the tributary being processed. The pointer generator monitors the fill levels of the payload buffers and inserts outgoing pointer justifications as necessary to avoid FIFO spillage. Normally, the pointer generator has a FIFO dead band of two bytes. The dead band can be collapse to one so that any incoming pointer justifications will be reflected by a corresponding outgoing justification with no attenuation. Signals are output by the pointer generator that identify outgoing V5 bytes and the tributary synchronous payload envelopes. On a per tributary basis, tributary path AIS and tributary idle (unequipped) can be inserted as controlled by microprocessor accessible registers. The idle code is selectable globally for the entire VC3 or TUG3 to be all-zeros or all-ones. It is also possible to force an inverted new data flag on individual tributaries for the purpose of diagnosing downstream pointer processors. Tributary path AIS is automatically inserted into outgoing tributaries
PROPRIETARY AND CONFIDENTIAL
103
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
if the pointer interpreter detects tributary path AIS on the corresponding incoming tributary.
9.29 Receive Tributary Path Overhead Processor (RTOP)
The tributary path overhead processor (RTOP) monitors the outgoing stream of the tributary payload processor (VTPP) and processes the tributaries within an STS-1, AU3, or TUG3. The RTOP can be configured to process all the VT1.5s or VT2s that can be carried in an STS-1 or all the TU11s or TU12s that can be carried in an AU3 or TUG3. The number of tributaries managed by each RTOP ranges from 21 (when configured to process all VT2s or all TU12s) to 28 (when configured to process all VT1.5s or all TU11s). The RTOP provides tributary performance monitoring of incoming tributaries. Bit interleaved parity of the incoming tributaries is computed and compared with the BIP-2 code encoded in the V5 byte of the tributary. Errors between the computed and received values are accumulated. RTOP also accumulates far end block error codes. Incoming path signal label is debounced and compared with the provisioned value. Path signal label unstable, path signal label mismatch and change of path signal label event are identified.
9.29.1 Clock Generator
The clock generator derives a 6.48 MHz clock from the 19.44 MHz system clock and distributes this to the tributary payload processor.
9.29.2 Timing Generator
The timing generator identifies the incoming tributary being processed at any given point in time. Based on the configuration of the RTOP (it can process various mixes of tributary types), the incoming timing generator extracts the STS1 SPE, VC3, or a single TUG3 from a VC4, and identifies the bytes within these envelopes that correspond to various types of overhead and those that carry specific tributaries to be processed. The identification of specific tributaries allows the error monitor and extract blocks to be time-sliced across the mix of tributaries present in the incoming data stream.
9.29.3 Error Monitor
The error monitor block is a time-sliced state machine. It relies on the timing generator block to identify the tributary being processed. The error monitor block contains a set of 12-bit counters that are used to accumulate tributary path BIP-2 errors, and a set of 11-bit counters to accumulate far end block errors (FEBE).
PROPRIETARY AND CONFIDENTIAL
104
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
The contents of the counters may be transferred to a holding RAM, and the counters reset under microprocessor control. Tributary path BIP-2 errors are detected by comparing the tributary path BIP-2 bits in the V5 byte extracted from the current multiframe, to the BIP-2 value computed for the previous multiframe. BIP-2 errors may be accumulated on a block or nibble basis as controlled by software configurable registers. Far end block errors (FEBEs) are detected by extracting the FEBE bit from the tributary path overhead byte (V5). Tributary path remote defect indication (RDI) and remote failure indication (RFI) are detected by extracting bit 8 and bit 4 respectively of the tributary path overhead byte (V5). The RDI is recognized when bit 8 of the V5 byte is set high for five or ten consecutive multiframes while RFI is recognized when bit 4 of V5 is set high for five or ten consecutive frames. The RDI and RFI bits may be treated as a two-bit code word. A code change is only recognized when the code is unchanged for five or ten frames. The tributary path signal label (PSL) found in the tributary path overhead byte (V5) is processed. An incoming PSL is accepted when it is received unchanged for five consecutive multiframes. The accepted PSL is compared with the associated provisioned value. The PSL match/mismatch state and UNEQ (unequipped) state is determined by the following:
Table 2 - Path Signal Label Mismatch State Accepted PSL PSLM State UNEQ State (Unequipped)
Expected PSL
000 000 000 000 001 001 001 001 PDI Code
000 001 PDI Code XXX 000, 001, PDI Code 000 001 PDI Code XXX 000, 001, PDI Code 000
Match Mismatch Mismatch Mismatch Mismatch Match Match Match Mismatch
Inactive Inactive Inactive Inactive Active (unequipped) Inactive Inactive Inactive Active (unequipped)
PROPRIETARY AND CONFIDENTIAL
105
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Expected PSL
Accepted PSL
PSLM State
UNEQ State (Unequipped)
PDI Code PDI Code PDI Code XXX 000, 001, PDI Code XXX 000, 001, PDI Code XXX 000, 001, PDI Code XXX 000, 001, PDI Code
001 PDI Code XXX 000, 001, PDI Code 000 001 XXX YYY
Match Match Mismatch Mismatch Match Match Mismatch
Inactive Inactive Inactive Active (unequipped) Inactive Inactive Inactive
Each time an incoming PSL differs from the one in the previous multiframe, the PSL unstable counter is incremented. Thus, a single bit error in the PSL in a sequence of constant PSL values will cause the counter to increment twice, once on the errored PSL and again on the first error-free PSL. The incoming PSL is considered unstable when the counter reaches five. The counter is cleared when the same PSL is received for five consecutive multiframes.
9.30 Receive Tributary Demapper (RTDM)
The Receive Tributary Demapper (RTDM) demaps up to 28 T1 or 21 E1 bit asynchronous mapped signals from an STS-1 SPE, TUG3 within a STM-1/VC4 or STM-1 VC3 payload. The bit asynchronous T1 mapping consists of 104 octets every 500 s (2 KHz) and is shown in Table 3. The bit asynchronous E1 mapping consists of 140 octets every 500us and is shown in Table 4.
Table 3 - Asynchronous T1 Tributary mapping
V5 RRRRRRIR 24 bytes - 8I J2 C1C2OOOOIR 24 bytes - 8I
PROPRIETARY AND CONFIDENTIAL
106
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
V5 Z6 C1C2OOOOIR 24 bytes - 8I Z7 C1C2RRRS1S2R 24 bytes - 8I
R: Fixed Stuff bit - set to logic `0' or `1' C: Stuff Control bit - set to logic `1' for stuff indication S: Stuff Opportunity bit - when stuff control bit is `0', stuff opportunity is I bit O: Overhead I: T1 payload information
Table 4
- Asynchronous E1 Tributary Mapping
V5 R 32 bytes - 8I R J2 C1C2OOOORR 32 bytes - 8I R Z6 C1C2OOOORR 32 bytes - 8I R Z7 C1C2RRRRRS1
PROPRIETARY AND CONFIDENTIAL
107
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
V5 S2I I I I I I I 31 bytes - 8I R
R: Fixed Stuff bit - set to logic `0' or `1' C: Stuff Control bit - set to logic `1' for stuff indication S: Stuff Opportunity bit - when stuff control bit is `0', stuff opportunity is I bit O: Overhead I: E1 payload information The RTDM buffers the tributary synchronous payload envelope bytes of the incoming tributaries in individual FIFOs to accommodate tributary pointer justifications. The RTDM performs majority voting on the tributary stuff control (C1, C2) bits. If the majority of each set of the stuff control bits indicate a stuff operation, then the associated stuff opportunity bit (S1, S2) will not carry T1 or E1 payload. Conversely, if the majority of the stuff control bits indicate a data operation, the appropriate stuff opportunity bit(s) will carry T1 or E1 payload. At each multiframe boundary, the RTDM indicates to the down stream parallel to serial converter (PISO) the status of the stuff control bits. For T1 streams, the parallel to serial converter can be controlled to generate 771, 772 or 773 T1 clock cycles. For E1 streams, the number of clock cycles is controllable to 1023, 1024 or 1025. The RTDM attenuates jitter introduced by pointer justification events. Tributary payload data is held in a FIFO. When a pointer justification is detected, the RTDM issues evenly spaced commands to the down stream parallel to serial converter block which makes 1/12 UI adjustments to the phase of its generated T1 output clock or 1/9 UI adjustments to the E1 clock. The number of commands sent per incoming pointer justification is based on the observation that four T1 or E1 frames are delivered or deleted for each full round of 104 VT1.5 (TU-11) or 140 VT2 (TU-12) pointer justifications.
9.31 Parallel In to Serial Out Converter (PISO)
The Parallel In to Serial Out Converter (PISO) serializes up to 28 T1 or 21 E1 tributaries which have been demapped from the STS-1 SPE or STM-1AU3 or
PROPRIETARY AND CONFIDENTIAL
108
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
VC3 via the Receive Tributary Demapper (RTDM). In conjunction with the Receive Tributary Demapper (RTDM) this block performs the desynchronizer function to provide a low jitter T1 or E1 serial clock and data. The Desynchronizer uses a combination of two clock generation techniques to desynchronize the demapped T1s and E1s. Incoming bit stuff events cause an extra bit of data to be generated or removed from the generated serial stream over the following 2KHz multi-frame. Pointer justifications are spread out by advancing or retarding the generated T1 or E1 clock phase. The 19.44MHz LREFCLK input is used to generate a nominal 1.544Mb/s or 2.048Mb/s clock over a 2KHz interval as indicated by the LDC1J1V1 input divided by four. A nominal T1 rate consists of 772 clocks in 500us. A nominal E1 rate consists of 1024 clocks in 500us. Stuff events, as indicated by the RTDM block, are compensated within the desynchronizer by generating three separate clocks to construct the faster or slower rate as shown in Table 5. A mixture of T1 clock cycles is generated using 12 REFCLK cycles (Fast T1 Cycles) and 13 REFCLK cycles (Slow T1 Cycles) to produce an overall rate of 1.544MHz over the 500us period. A mixture of E1 clock cycles is generated using 9 REFCLK cycles (Fast E1 cycles) and 10 REFCLK cycles (Slow E1 cycles) to produce an overall rate of 2.048MHz over the 500us period. Table 5 shows the number of fast and slow cycles required to generate all three T1 and E1 rates.
Table 5 Clock Rate - Desynchronizer Clock Generation Algorithm Fast T1 Cycles Slow T1 Overall Cycles T1 Cycles Fast E1 Cycles Slow E1 Cycles Overall E1 Cycles
Slow Nominal Fast
303 316 329
468 456 444
771 772 773
510 520 530
513 504 495
1023 1024 1025
Pointer justification events, as indicated by the RTDM block, are compensated within the desynchronizer by advancing or retarding the phase of the generated fast, slow and nominal clocks during the 2KHz period. Because pointer justification have a limited frequency of occurrence the phase adjustments are leaked out slowly. Twelve phase adjustments will remove or add an entire T1 clock whereas nine phase adjustments will remove or add an entire E1 clock. The number of phase adjustments needed per pointer justification is on average 89.077 for T1 or 65.829 for E1. These pointer adjustments are spread out over a 1 second period.
PROPRIETARY AND CONFIDENTIAL
109
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
9.32 DS3 Mapper Drop Side (D3MD)
The DS3 Mapper DROP Side (D3MD) block demaps a DS3 signal from an STS-1 (STM-0/AU3) payload. The asynchronous DS3 mapping consists of 9 rows every 125 s (8 KHz). Each row contains 621 information bits, 5 stuff control bits, 1 stuff opportunity bit, and 2 overhead communication channel bits. Fixed stuff bytes are used to fill the remaining bytes. The asynchronous DS3 mapping is shown in Table 6.
Table 6
J1 2 x 8R 2 x 8R 2 x 8R STS POH 2 x 8R 2 x 8R 2 x 8R 2 x 8R 2 x 8R 2 x 8R
- Asynchronous DS3 mapping to STS-1 (STM-0/AU3)
RRCIIIII RRCIIIII RRCIIIII RRCIIIII RRCIIIII RRCIIIII RRCIIIII RRCIIIII RRCIIIII 25 x 8I 25 x 8I 25 x 8I 25 x 8I 25 x 8I 25 x 8I 25 x 8I 25 x 8I 25 x 8I 2 x 8R 2 x 8R 2 x 8R 2 x 8R 2 x 8R 2 x 8R 2 x 8R 2 x 8R 2 x 8R CCRRRRRR CCRRRRRR CCRRRRRR CCRRRRRR CCRRRRRR CCRRRRRR CCRRRRRR CCRRRRRR CCRRRRRR 26 x 8I 26 x 8I 26 x 8I 26 x 8I 26 x 8I 26 x 8I 26 x 8I 26 x 8I 26 x 8I 2 x 8R 2 x 8R 2 x 8R 2 x 8R 2 x 8R 2 x 8R 2 x 8R 2 x 8R 2 x 8R CCRROORS CCRROORS CCRROORS CCRROORS CCRROORS CCRROORS CCRROORS CCRROORS CCRROORS 26 x 8I 26 x 8I 26 x 8I 26 x 8I 26 x 8I 26 x 8I 26 x 8I 26 x 8I 26 x 8I
R: Fixed Stuff bit - set to logic `0' or `1' C: Stuff Control bit - set to logic `1' for stuff indication S: Stuff Opportunity bit - when stuff control bit is `0', stuff opportunity is I bit O: Overhead communication channel I: DS3 payload information
9.32.1 DS3 Demapper
The D3MD performs majority vote on the received C-bits. If 3 out of 5 C-bits are `1's, the associated S bit is interpreted as a stuff bit. If 3 out of 5 C-bits are `0's, the associated S bit is interpreted as an Information bit. The information bits are written to an elastic store and the Fixed Stuff bits (R) are ignored. Given a path signal label mismatch (PSLM) or path signal label unstable (PSLU), the D3MD ignores the STS-1 (STM-0/AU3) SPE and writes a DS3 AIS pattern to the elastic store. In addition, the desynchronization algorithm assumes a nominal
PROPRIETARY AND CONFIDENTIAL
110
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
ratio of data to stuff bits carried in the S bits (1 out of 3 S bits is assumed to be an information (data) bit). DS3 AIS is shown in Table 7.
Table 7
X (1) X (1) P (p) P (p) M (0) M (1) M (0) D F (1) D C (0) D F (0) D C (0) D F (0) D C (0) D F (1) D D D D D D D
- DS3 AIS format.
F (1) F (1) F (1) F (1) F (1) F (1) D D D D D D C (0) C (0) C (0) C (0) C (0) C (0) D D D D D D F (0) F (0) F (0) F (0) F (0) F (0) D D D D D D C (0) C (0) C (0) C (0) C (0) C (0) D D D D D D F (0) F (0) F (0) F (0) F (0) F (0) D D D D D D C (0) C (0) C (0) C (0) C (0) C (0) D D D D D D F (1) F (1) F (1) F (1) F (1) F (1) D D D D D D
*
valid M-frame alignment bits (M-bits), M-subframe alignment bits (F-bits), and parity bit of the preceding M-frame (P-bits). The two P-bits are identical, either both are zeros or ones. all the C-bits in the M-frame are set to zeros the X-bits are set to ones the information bit (84 Data bits with repeating sequence of 1010..)
* * *
9.32.2 DS3 Demapper Elastic Store
The elastic store block is provided to compensate for frequency differences between the DS-3 stream extracted from the STS-1 (STM-0/AU3) SPE and the incoming CLK52M. The DS3 Demapper extracts I bits from the STS-1 (STM-0/AU3) SPE and writes the bits into a 128 bit (16 byte) elastic store. Eight bytes are provided for SONET/SDH overhead (3 bytes for TOH, 1 byte for a positive stuff, 1 byte for POH) and DS3 reserve stuffing bits (2 bytes for R bits, and 3 overhead bits which is rounded-up to 1 byte). The remaining 8 bytes are provided for path pointer adjustments. Data is read out of the Elastic Store using a divide by 8 version of the input CLK52M clock. If an overflow or underflow condition occurs, an interrupt is optionally asserted and the Elastic Store read and write address are reset to the startup values (logically 180 degrees apart).
PROPRIETARY AND CONFIDENTIAL
111
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
9.32.3 DS3 Desynchronizer
The Desynchronizer monitors the Elastic Store level to control the de-stuffing algorithm to avoid overflow and underflow conditions. The Desynchronizer assumes either a 51.84 MHz clock (provided internally) or a 44.928 MHz clock (provided via input CLK52M). When using a 44.928 MHz CLK52M clock, the DS3 clock is generated using a fixed 8 KHz interval. The 8KHz interval is subdivided into 9 rows. Each row contains either 621 or 622 clock periods. The DS3RICLK contains 624 pulses at 72KHz (9*8KHZ). To generate 621 pulses, a gap pattern of 207 clocks + 1 clock gap + 207 clocks + 1 clock gap + 207 clocks + 1 clock gap is used. To generate 622 pulses, a gap pattern of 207 clocks + 1 clock gap + 207 clocks + 1 clock gap + 208 clocks is used. When using a 51.84 MHz CLK52M clock, the DS3 clock is generated using similar gapping patterns. To generate 621 pulses per row, a gapping pattern of 63 * (7 clocks + 1 clock gap) + 36 * (5 clocks + 1 clock gap) is used. To generate 622 pulses per row, a gapping pattern of 63 * (7 clocks + 1 clock gap) + 35 * (5 clocks + 1 clock gap) + 6 clocks is used. Table 8 illustrates the gap patterns used to generate the desynchronized DS3 clock under the normal, DS3 AIS, faster and slower status. The faster pattern is used to drain the elastic store to avoid overflows. The slower pattern is used to allow the elastic store to fill to avoid underflows.
PROPRIETARY AND CONFIDENTIAL
112
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Table 8
- DS3 desynchronizer clock gapping algorithm. Normal or DS3 AIS Run Faster Run Slower
Row Number
1 2 3 4 5 6 7 8 9
621 621 622 621 621 622 621 621 622
621 621 622 621 622 622 621 622 622
621 621 622 621 621 621 621 621 621
9.33 Transmit Tributary Path Overhead Processor (TTOP)
The Transmit Tributary Path Overhead Processor (TTOP) generates the path overhead for up to 28 VT1.5/TU-11s or 21 VT2/TU-12s. When configured for SONET compatible operation, the TTOP inserts the four tributary path overhead bytes (V5, J2, Z6, and Z7) to each tributary. The TTOP may also be configured for SDH compatible operation. The incoming STM-1 stream may carry three AU3s or an AU4 with three TUG3s. The TTOP computes the BIP-2 code in the current tributary SPE and inserts the result into the BIP-2 bits of the V5 byte in the next tributary SPE. The tributary path signal label in the V5 byte of each tributary can be sourced from internal registers. The tributary far end block error bit in the V5 byte of each tributary is inserted based of the BIP error count detected at a companion RTOP TSB. The tributary remote failure indication and remote defect indication bits in the V5 or the Z7 byte of each tributary is inserted based on the tributary alarm status from the companion Tributary Remote Alarm Processor, TRAP, TSB. The TTOP inserts the tributary trail trace identifier into the J2 byte. Each tributary is provided with a 64-byte buffer to store the identifier. One shadow buffer is available for temporary replacement of a selected transmitted TTI while the 64-byte identifier buffer is being updated. Data is retrieved sequentially from the active buffer at each J2 byte position. The shadow buffer can be programmed with new messages without timing constraints when inactive. An inactive 64-byte identifier buffer can also be programmed with new messages
PROPRIETARY AND CONFIDENTIAL
113
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
without timing constraints. Programming for TTI buffers is done one buffer at a time by first programming the shadow buffer, switching to the shadow buffer for the desired tributary, updating the desired tributary identifier buffer and finally switching back from the shadow buffer to the tributary buffer. Switching between the shadow buffer and normal buffer is synchronized to the start of each identifier on a per-tributary basis.
9.34 Transmit Remote Alarm Processor (TRAP)
When configured for SONET compatible operation, the TRAP SONET/SDH Transmit Remote Alarm Processor processes remote alarm indications of tributaries in an STS-3 stream. The virtual tributaries within an STS-1 stream may be configured to accept either VT1.5 or VT2 tributary types. The TRAP may also be configured for SDH compatible operation. The incoming STM-1 stream may carry three AU3s or an AU4 with three TUG3s. The TRAP may be configured to insert tributary remote defect indications (RDI-V) and tributary remote error indications (REI-V) via the TTOP block. These indications may originate from three sources: (1) Based on alarms detected in tributaries received on the Telecom Drop bus, LDDATA[7:0]. The exact behavior is configured using the SONET/SDH Master Tributrary Remote Defect Indication Control Register and the SONET/SDH Master Tributary Auxiliary Remote Defect Indication Register. (2) Based on two independent serial alarm ports, RADEAST and RADWEST. REI indications are generated based on the sampled BIP-2 error values. RDI indications are based on the sampled RDI (Remote Defect Indication) and RFI (Auxiliary Remote Defect Indication) values. (3) Using the FORCEEN feature in the TRAP Control Registers to manually force desired values using the RDI (Remote Defect Indication) and RFI (Auxiliary Remote Defect Indication) bits. The source of alarm status can be configured on a per-tributary basis. As well, alarm information from tributaries in any of the three sources of remote alarms can be mapped to arbitrary tributaries in the outgoing data stream via the Indirect Remote Alarm Tributary Register and the Indirect Datapath Tributary Register of the TRAP block. Two methods of encoding tributary remote alarms are supported: Non-extended RDI and Extended RDI. This selection is made on a per-tributary basis by setting the ERDI bits of the TRAP Control registers and the TTOP control registers. In Non-extended RDI mode, RDI indications are encoded as a one bit
PROPRIETARY AND CONFIDENTIAL
114
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
value (RDI, Remote Defect Indication) reflected in the V5 byte of the outgoing tributrary path overhead. In Extended RDI mode, RDI indications are encoded as a two bit value (RDI, Remote Defect Indication and RFI, Auxiliary Remote Defect Indication), and are reflected in both the V5 byte and Z7 byte of the outgoing tributary path overhead. Specifically, the outgoing path overhead bits are mapped as follows:
Path Overhead bits
Non-extended RDI (ERDI=0)
Extended RDI (ERDI=1)
V5 bit 3 V5 bit 8 Z7 bit 5 Z7 bit 6 Z7 bit 7
REI RDI 0 0 0
REI RDI RDI RFI NOT(RFI)
In all cases, the RDI-V state will be sent for a minimum of 10 multiframes before changing, unless a higher priority alarm is required.
9.35 Transmit Tributary Mapper (TTMP)
The Transmit Tributary Mapper block bit asynchronously maps up to 28 T1 or 21 E1 streams into an STS-1 SPE, TUG3 in a STM-1/VC4 or STM-1/VC3 payload. The TTMP compensates for any frequency differences between the incoming individual serial bit rates and the available STS-1 or STM-1/VC3 payload capacity. The asynchronous T1 mapping consists of 104 octets every 500 s (2 KHz). The asynchronous E1 mapping consists of 140 octets every 500 s (2 KHz). Refer to the RTDM block for a description of the asynchronous T1 and E1 mappings. The tributary mapper is a time-sliced state machine which uses a payload buffer as an elastic store. The T1 or E1 streams are read from the payload buffer, and mapped into VT1.5 Payloads and VT2 Payloads using bit asynchronous mapping only. The Tributary Mapper compensates for phase and frequency offsets using bit stuffing. A jitter-reducing control loop is used to monitor the Payload Buffer depth
PROPRIETARY AND CONFIDENTIAL
115
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
and reduce mapping jitter to 1.0 UI. To reduce mapping jitter even further, a dither technique is inserted between the control loop and the stuff bit generator resulting in an acceptable desynchronizer mapping jitter of about 0.3 UI. The Tributary Mapper may optionally act as a time switch. When Time Switch Enable is active, the association of Tributary Mapper VT Payloads to logical FIFO data streams is software configurable. There are two pages in the time switch configuration RAM. One page is software selectable to be the active page and the other the stand-by page. The configuration in the active page is used to associate outgoing VT Payloads to logical FIFOs. The stand-by page can be programmed to the next switch configuration. Change of page selection is synchronized to incoming stream frame boundaries. When Time Switch Enable is inactive, the association of outgoing VT Payloads to logical FIFOs is fixed. The TTMP outputs the STS-1, TUG3 in a STM-1/VC4 or STM-1/VC3 with the bit asynchronous mapped T1s or E1s onto an internal bus for further processing by the Transmit Tributary Payload Processor block.
9.36 Serial In to Parallel Out Converter (SIPO)
The Serial In to Parallel Out Converter (SIPO) accepts serial data from up to 28 T1 or 21 E1 sources and converts these streams to byte serial format. The bytes are passed to the Transmit Tributary Mapper (TTMP) for bit asynchronous mapping into the STS-1.
9.37 DS3 Mapper ADD Side (D3MA)
The DS3 Mapper ADD Side (D3MA) block maps a DS3 signal into an STS-1 (STM-0/AU3) payload and compensate for any frequency differences between the incoming DS3 serial bit rate (TICLK) and the available STS-1 (STM-0/AU3) SPE mapped payload capacity. The asynchronous DS3 mapping consists of 9 rows every 125 s (8 KHz). Each row contains 621 information bits, 5 stuff control bits, 1 stuff opportunity bit, and 2 overhead communication channel bits. Fixed stuff bytes are used to fill the remaining bytes. Please refer to section 9.32 for a description of the DS3 mapping.
9.37.1 DS3 Mapper Serializer
High speed serial data from the DS3-TRAN block is deserialized and written into the Elastic Store.
PROPRIETARY AND CONFIDENTIAL
116
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
9.37.2 DS3 Mapper Elastic Store
The elastic store block is provided to compensate for frequency differences between the DS3 stream from the DS3-TRAN block and the STS-1 (STM-0/AU3) SPE capacity. The DS3 Serializer writes data into the elastic store at the TICLK/8 rate while data is read out at the stuffed STS-1 (STM-0/AU3) byte rate. If an overflow or underflow condition occurs, an interrupt is optionally asserted and the Elastic Store read and write address are reset to the startup values (logically 180 degrees apart). The Elastic store is 128 bits (16 bytes) to allow for a fixed read/write pointer lag of 7 bytes (3 bytes for TOH, 1 byte for POH, 2 bytes for R bits, and 3 overhead bits which is rounded-up to 1 byte). Four bytes are also added on either side for positive and negative threshold detection.
9.37.3 DS3 Synchronizer
The DS3 Synchronizer performs the mapping of the DS3 into the STS-1 (STM-0/AU3) SPE. The DS3 Synchronizer monitors the Elastic Store level to control the stuffing algorithm to avoid overflow (i.e. run faster) and underflow (i.e. run slower) conditions. The fill level of the elastic store is monitored and stuff opportunities in the DS3 mapping are used to center the Elastic Store. To consume a stuff opportunity, the five C-bits on a row are set to ones and the S bit is used to carry an DS3 information bit. When the S bit is not used to carry information, the C-bits on the row are set to zeros. The DS3 synchronizer uses a fixed bit leaking algorithm which leaks 8 bits of phase buildup in 500 s. The 8kHz STS-1 (STM-0/AU3) frame interval is subdivided into 9 rows. Each row contains one stuff opportunity. Table 9 illustrates the stuffing implementation where S means stuff bit and I means an information bit (DS3 data).
PROPRIETARY AND CONFIDENTIAL
117
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Table 9
- DS3 synchronizer bit stuffing algorithm. Normal or DS3 AIS Run Faster Run Slower
Row Number
1 2 3 4 5 6 7 8 9
S S I S S I S S I
S S I S I I S I I
S S I S S S S S S
Under microprocessor control, the incoming DS3 stream can be overwritten with the framed DS3 AIS. When asserting DS3 AIS, a nominal stuff pattern is used as illustrated above. Please refer to the D3MD functional description section for a description of the DS3 AIS frame. The D3MA outputs the STS-1 (STM-0/AU3) with the mapped DS3 onto the Line Add bus, LADATA[7:0].
9.38 Egress System Interface (ESIF)
The Egress System Interface (ESIF) block provides system side serial clock and data access as well as H-MVIP access for up to 28 T1 or 21 E1 transmit streams. There are several master and slave clocking modes for serial clock and data system side access to the T1 and E1 streams. When enabled for 8.192Mb/s H-MVIP there are three separate interfaces for data, CAS signaling and CCS signaling. The H-MVIP signaling interfaces can be used in combination with the serial clock and data and SBI interface in certain applications. Control of the system side interface is global to TEMUX and is selected through the SYSOPT[2:0] bits in the Global Configuration register at address 0001H. The system interface options are serial clock and data, H-MVIP, SBI bus, SBI bus with CAS or CCS H-MVIP and serial clock and data with CCS H-MVIP. Two Clock Master modes provide a serial clock and data egress interface with per link clocking provided by TEMUX. The clock master modes are Clock Master: NxChannel and Clock Master: Clear Channel. Four Clock slave modes provide three serial clock and data egress interfaces and a H-MVIP interface all with
PROPRIETARY AND CONFIDENTIAL
118
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
externally sourced clocking. The slave modes are Clock Slave: EFP Enabled, Clock Slave: External Signaling, Clock Slave: Clear Channel and Clock Slave: HMVIP. The egress serial clock and data interface clocking modes are selected via the EMODE[2:0] bits in the T1/E1 Egress Serial Interface Mode Select register. In all egress Clock Master modes the transmit clock can be sourced from either the common transmit clock, CTCLK, one of the two recovered clocks, RECVCLK1 and RECVCLK2, or the received clock for that link. The selection between CTCLK, RECVCLK1 and RECVCLK2 as the reference transmit clock is the same for all T1/E1 framers. Jitter attenuation can be applied to all master mode clocks with the TJAT.
Figure 17
CTCLK
- Clock Master: NxChannel
Receive CLK[1:28]
ED[1:28] ECLK[1:28]
ED[x] Tim ed to ECLK[x]
ESIF Egress System Inte rface
T1-XBAS/E1-TRAN BasicTransm itter: Fram e Gene ration, Alarm Insertio n, Signaling Insertion, Trunk Conditioning Line Coding
T JAT Digital PLL
Transmit C LK[1 :28]
Transm it D ata[1 :28]
TRANSM ITTER
Clock Master: NxChannel mode does not indicate frame alignment to the upstream device. Instead, ECLK[x] is gapped on a per channel basis so that a subset of the 24 channels in a T1 frame or 32 channels in an E1 frame are inserted on ED[x]. Channel insertion is controlled by the IDLE_CHAN bits in the TPSC block's Egress Control Bytes. The framing bit position is always gapped, so the number of ECLK[x] pulses is controllable from 0 to 192 pulses per T1 frame or 0 to 256 pulses per E1 frame on a per-channel basis. The parity functions should not be enabled in NxChannel mode.
Figure 18
CTCLK
- Clock Master: Clear Channel
Receive CLK[1:28]
ED[1:28] ECLK[1:28]
ED[x] Tim ed to ECLK[x]
ESIF Egress System Inte rface
TJAT Digital PLL
Transmit C LK[1 :28]
Transmit D ata[1 :28]
TRANSM ITTER
PROPRIETARY AND CONFIDENTIAL
119
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Clock Master: Clear Channel mode has no frame alignment therefore no frame alignment is indicated to the upstream device. ECLK[x] is a continuous clock at 1.544Mb/s for T1 links or 2.048Mb/s for E1 links.
Figure 19 - Clock Slave: EFP Enabled
TRANSMITTER
ED[1:28] EFP[1:28] CEFP CECLK
ESIF Egress System Interface
T1-XBAS/E1-TRAN BasicTransm itter: Frame Generation, Alarm Insertion, Signaling Insertion, Trunk Conditioning Line Coding
TJAT Digital PLL TJAT FIFO
Transmit C LK[1:28]
Transm it D ata[1:28]
Inputs Tim ed to CECLK
In Clock Slave: EFP Enabled mode, the egress interface is clocked by the common egress clock, CECLK. The transmitter is either frame-aligned or superframe-aligned to the common egress frame pulse, CEFP, via the CEMFP bit in the Master Egress Slave Mode Serial Interface Configuration register. EFP[x] is configurable to indicate the frame alignment or the superframe alignment of ED[x]. CECLK can be enabled to be either a 1.544 MHz clock for T1 links or a 2.048 MHz clock for T1 and E1 links. The CECLK2M bit in the Master Egress Slave Mode Serial Interface Configuration register selects the 2.048MHz clock for T1 operation.
Figure 20 - Clock Slave: External Signaling
TRANSMITTER
ED[1:28] ESIG[1:28] CEFP CECLK
ESIF Egress System Interface
T1-XBAS/E1-TRAN BasicTransm itter: Frame Generation, Alarm Insertion, Signaling Insertion, Trunk Conditioning Line Coding
TJAT Digital PLL TJAT FIFO
Transmit C LK[1:28]
Transm it D ata[1:28]
Inputs Tim ed to CECLK
In Clock Slave: External Signaling mode, the egress interface is clocked by the common egress clock, CECLK. The transmitter is either frame-aligned or superframe-aligned to the common egress frame pulse, CEFP, via the CEMFP bit in the Master Egress Slave Mode Serial Interface Configuration register. The ESIG[x] signal contains the robbed-bit signaling data to be inserted into Transmit
PROPRIETARY AND CONFIDENTIAL
120
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Data[x], with the four least significant bits of each channel on ESIG[x] representing the signaling state (ABCD or ABAB in T1 SF mode). EFP[x] is not available in this mode.
Figure 21 - Clock Slave: Clear Channel
TRANSMITTER
ED[1:28]
ESIF Egress System Interface
TJAT Digital PLL TJAT FIFO
Transmit C LK[1:28]
ECLK[1:28]
Transm it D ata[1:28]
Input Tim ed to ECLK[x]
In Clock Slave: Clear Channel mode, the egress interface is clocked by the externally provided egress clock, ECLK[x]. ECLK[x] must be a 1.544 MHz clock for T1 links or a 2.048 MHz clock for E1 links. In this mode the T1/E1 framers are bypassed except for the TJAT which may or may not be bypassed depending on the setting of the TJATBYP bit in the T1/E1 Egress Line Interface Options register. Typically the TJAT would be bypassed unless jitter attenuation is required on ECLK[x].
Figure 22 - Clock Slave: H-MVIP
TRANSMITTER
MVED[1:7] CASED[1:7] CCSED CMVFP CMVFPC CMV8MCLK ESIF Egress System Inte rface T1-XBAS/E1-TRAN BasicTransm itte r: Frame Generation, Alarm Insertio n, Signaling Insertion, Trunk Co nditioning Line Coding TJAT Digital PLL TJAT FIFO Transmit C LK[1:28]
Transm it D ata[1:28]
Inputs Tim ed to CMV8MCLK
When Clock Slave: H-MVIP mode is enabled a 8.192Mb/s H-MVIP egress interface multiplexes up to 672 channels from 28 T1s or 21 E1s, up to 672 channel associated signaling (CAS) channels from 28 T1s or 21 E1s and common channel signaling from up to 28 T1s or 21 E1s. The H-MVIP interfaces use common clocks, CMV8MCLK and CMVFPC, and frame pulse, CMVFPB, for synchronization.
PROPRIETARY AND CONFIDENTIAL
121
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Seven H-MVIP data signals, MVED[1:7], share pins with serial PCM data inputs, ED[x], to provide H-MVIP access for up to 672 data channels. The H-MVIP mapping is fixed such that each group of four nearest neighbor T1 or E1 links make up the individual 8.192Mb/s H-MVIP signal. The multiplexed data input is shared with the lowest numbered T1 or E1 serial PCM link in the bundle, for example MVED[2] combines the DS0s or timeslots of ED[5,6,7,8] and is pin multiplexed with ED[5]. This mode is selected when the SYSOPT[2:0] bits in the Global Configuration register are set to H-MVIP. A separate seven signal H-MVIP interface is for access to the channel associated signaling for 672 channels. The CAS H-MVIP interface is time division multiplexed exactly the same way as the data channels. The CAS HMVIP is synchronized with the H-MVIP data channels when SYSOPT[2:0] is set to H-MVIP mode. Over a T1 or E1 multi-frame the four CAS bits per channel are repeated with each data byte. Four stuff bits are used to pad each CAS nibble (ABCD bits) out to a full byte in parallel with each data byte. The egress CAS HMVIP interface, CASED[1:7], is multiplexed with seven serial PCM egress data pins, ED[2,6,10,14,18,22,26]. The CAS H-MVIP interface can be used in parallel with the SBI Add bus as an alternative method for accessing the CAS bits while data transfer occurs over the SBI bus. This is selected when the SYSOPT[2:0] bits in the Global Configuration register are set to "SBI Interface with CAS or CCS H-MVIP Interface" and the ECCSEN bit in the T1/E1 Egress Serial Interface Mode Select register is set to 0. A separate H-MVIP interface consisting of a single signal is used to time division multiplex the common channel signaling (CCS) for all T1s and E1s and additionally the V5 channels in E1 mode. The CCS H-MVIP interface, CCSED, is not multiplexed with any other pins. CCSED can be used in parallel with the Clock Slave:H-MVIP mode when SYSOPT[2:0] is set to "H-MVIP Interface" and the ECCSEN bit in the T1/E1 Egress Serial Interface Mode Select register is set to 1, a Clock Slave serial interface when SYSOPT[2:0] is set to "Serial Clock and Data Interface with CCS H-MVIP Interface", or the SBI Add bus when SYSOPT[2:0] is set to "SBI Interface with CAS or CCS H-MVIP Interface" and the ECCSEN bit is set to 1. The V5 channels in E1 mode can also be enabled over CCSEN when the ETS15EN and ETS31EN bits in the T1/E1 Egress Serial Interface Mode Select register are set to 1. When accessing the CAS or CCS signaling via the H-MVIP interface in parallel with the SBI interface a transmit signaling elastic store is used to adapt any timing differences between the data interface and the CAS or CCS H-MVIP interface.
PROPRIETARY AND CONFIDENTIAL
122
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Figure 23
- Clock Master: Serial Data and H-MVIP CCS
TRANSMITTER
ED[1:28] EFP[1:28] ICLK[1:28]
ED[x] Inputs Timed to ICLK[x]
CCSED CMVFP CMVFPC CMV8MCLK
ESIF Egress System Interface
T1-XBAS/E1-TRAN BasicTransmitter: Frame Generation, Alarm Insertion, Signaling Insertion, Trunk Conditioning Line Coding
TJAT Digital PLL TJAT FIFO
Transmit CLK[1:28]
Transmit Data[1:28]
Inputs Timed to CMV8MCLK
When Clock Master: Serial Data and H-MVIP CCS mode is enabled, payload data may be sourced through the egress serial interface, while common channel signaling is sourced in parallel through the H-MVIP interface. The H-MVIP egress interface multiplexes common channel signaling from up to 28 T1s or 21 E1s. The H-MVIP interfaces use common clocks, CMV8MCLK and CMVFPC, and frame pulse, CMVFPB, for synchronization. Common channel signaling over H-MVIP uses a Clock Slave serial interface, selected when SYSOPT[2:0] is set to "Serial Clock and Data Interface with CCS H-MVIP Interface". CCSED is a single dedicated input pin sampled by CMV8MCLK, used to time division multiplex the common channel signaling (CCS) for all T1s and E1s and additionally the V5 channels in E1 mode. The V5 channels in E1 mode can also be enabled over CCSED when the ETS15EN and ETS31EN bits in the T1/E1 Egress Serial Interface Mode Select register are set to 1. The ingress clock, ICLK[x], is a 1.544MHz or 2.048MHz clock generated from the 16.384MHz CMV8MCLK. (Note that in T1 mode, this clock does not divide down to T1 rate evenly, resulting in a gappy clock. The minimum period is 10 times that of CMV8MCLK.) ICLK[x] is pulsed for each bit in the 193 bit T1 or 256 bit E1 frame (i.e. NxDS0 controls are not applicable in this mode). Payload data on ID[x] is output relative to this clock. The ingress frame alignment is indicated by TEMUX on IFP[x], again timed to ICLK[x]. Note that several of the serial PCM egress data pins ED[x] are multiplexed with the egress data H-MVIP data interface. ED[1,5,9,13,17,21,25] share pins with the H-MVIP data signals MVED[1:7]. ED[2,6,10,14,18,22,26] share pins with the H-MVIP CAS signals CASED[1:7].
PROPRIETARY AND CONFIDENTIAL
123
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
9.39 Ingress System Interface (ISIF)
The Ingress System Interface (ISIF) block provides system side serial clock and data access as well as MVIP access for up to 28 T1 or 21 E1 receive streams. There are several master and slave clock modes for serial clock and data system side access to the T1 and E1 streams. When enabled for 8.192Mb/s H-MVIP there are three separate interfaces for data and signaling. The H-MVIP signaling interfaces can be used in combination with the serial clock and data and SBI interface in certain applications. Control of the system side interface is global to TEMUX and is selected through the SYSOPT[2:0] bits in the Global Configuration register at address 0001H. The system interface options are serial clock and data, H-MVIP, SBI bus, SBI bus with CAS or CCS H-MVIP and serial clock and data with CCS H-MVIP. Three Clock Master modes provide a serial clock and data ingress interface with clocking provided by TEMUX. The clock master modes are Clock Master: Full T1/E1, Clock Master : NxChannel, Clock Master: Clear Channel. Two Clock slave modes provide two serial clock and data ingress interfaces and a H-MVIP interface. All Clock slave modes accept externally sourced clocking. The clock slave modes are: Clock Slave: External Signaling or Clock Slave: H-MVIP. The ingress serial clock and data interface clocking modes are selected via the IMODE[1:0] bits in the T1/E1 Ingress Serial Interface Mode Select register. Clock Master: NxChannel and Clock Master: Full T1/E1 use the same IMODE[1:0] selection and are differentiated by the INXCHAN[1:0] bits in the same ragister as IMODE[1:0].
Figure 24 - Clock Master: Full T1/E1
ID[1:28] IFP[1:28]
ID[x], IFP[x] Tim ed to IC LK [1:28]
ISIF Ingress System Interface
FRAM Framer: Slip Bu ffer RAM FRM R Framer: Fram e Alignmen t, Alarm Extraction
RECEIVER
RJAT Digita l Jitter Attenuator
Receive Data[1:28] Receive CLK[1:28]
ICLK[1:28]
In Clock Master: Full T1/E1 mode, the elastic store is bypassed and the ingress clock (ICLK[x]) is a jitter attenuated version of the 1.544 MHz or 2.048 MHz receive clock coming from either the M13 multiplex or SONET/SDH demapper. Jitter attenuation is selectable by the RJATBYP bit in the T1/E1 Receive Options register. ICLK[x] is pulsed for each bit in the 193 bit T1 or 256 bit E1 frame. The ingress data appears on ID[x] and the ingress frame alignment is indicated by
PROPRIETARY AND CONFIDENTIAL
124
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
IFP[x]. In this mode, demultiplexed or demapper T1 or E1 data passes through the TEMUX unchanged during out-of-frame conditions, similar to an offline framer system. When the TEMUX is the clock master in the ingress direction, the elastic store is used to buffer between the ingress and egress clocks to facilitate per-Channel loopback.
Figure 25 - Clock Master: NxChannel
ID[1:28] IFP[1:28] ICLK[1:28]
ID[x], IFP[x] Tim ed to gapped ICLK [1:28]
ISIF Ingress System Inte rface
FRAM Fram er: Slip Bu ffer RAM FRM R Framer: Fram e Alignmen t, Alarm Extraction
RECEIVER
RJAT Digita l Jitter Attenuator
Receive Data[1:28] Receive CLK[1:28]
In Clock Master: NxChannel mode, ICLK[x] is a gapped version of the jitter attenuated 1.544 MHz or 2.048 MHz receive clock coming from either the M13 multiplex or SONET/SDH demapper. ICLK[x] is gapped on a per channel basis so that a subset of the 24 channels in the T1 frame or 32 channels in an E1 frame is extracted on ID[x]. IFP[x] indicates frame alignment but has no clock since it is gapped during the framing bits. Channel extraction is controlled by the RPSC block. The framing bit position is always gapped, so the number of ICLK[x] pulses is controllable from 0 to 192 pulses per T1 frame or 0 to 256 pulses per E1 frame on a per-channel basis. In this mode, demultiplexed or demapped T1 or E1 streams pass through the TEMUX unchanged during out-offrame conditions. The parity functions are not usable in NxChannel mode. When the TEMUX is the clock master in the ingress direction, the elastic store is used to buffer between the ingress and egress clocks to facilitate per-Channel loopback.
Figure 26 - Clock Master: Clear Channel
ID[x]Timed to IC LK [x]
RECEIVER
ISI F Ingress Syst em Inte rfac e
ID[1 :28] ICLK[ 1:28]
RJAT Digita l Jitter Attenuator
Receive Data[1:28] Receive CLK[1:28]
PROPRIETARY AND CONFIDENTIAL
125
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
In Clock Master: Clear Channel mode, the elastic store is bypassed and the ingress clock (ICLK[x]) is a jitter attenuated version of the 1.544 MHz or 2.048 MHz receive clock coming from either the M13 multiplex or SONET/SDH demapper. The ingress data appears on ID[x] which no frame alignment indication. Per channel loopbacks are not available in Clear channel mode. The RCVCLRCH mode bit in the T1/E1 Receive Options register must be set to 1 in Clock master: Clear Channel mode.
Figure 28
CICLK CIFP
- Clock Slave: External Signaling
ELST Elastic Store
FRAM Framer: Slip Buffer RAM FRM R Framer: Frame Alignmen t, Alarm Extraction
RECEIVER
ID[1:28] IFP[1:28] ISIG[1:28 ]
ID[x], IFP[x], ISIG[x] Tim ed to CICLK
ISIF Ingress System Inte rface
RJAT Digita l Jitter Attenuator
Receive Data[1:28] Receive CLK[1:28]
In Clock Slave: External Signaling mode, the elastic store is enabled to permit CICLK to specify the ingress-side timing. The ingress data on ID[x] and signaling ISIG[x] are bit aligned to the 1.544 MHz or 2.048 MHz common ingress clock (CICLK) and are frame aligned to the common ingress frame pulse (CIFP). CICLK can be enabled to be a 1.544 MHz clock or a 2.048 MHz clock. ISIG[x] contains the robbed-bit signaling state (ABCD or ABAB) in the lower four bits of each channel. IFP[x] indicates either the frame or superframe alignment on ID[x].
Figure 29 - Clock Slave: H-MVIP
RECEIVER
FRAM Framer: Slip Bu ffer RA M FRMR Framer: Frame A lignmen t, Alarm Ext raction RJAT Digita l Jitter Attenuator Receive Data[1:28] Receive CLK[1:28]
MVID[1 :7] CASID [1:7] CCSID CMVFP CMVFPC CMV8MCLK
Inp ut s Ti me d to C M V8 MC LK
ELST Elas tic Store ISI F Ingress Syst em Inte rfac e
When Clock Slave: H-MVIP mode is enabled a 8.192Mb/s H-MVIP ingress interface multiplexes up to 672 channels from 28 T1s or 21 E1s, up to 672 channel associated signaling (CAS) channels from 28 T1s or 21 E1s and
PROPRIETARY AND CONFIDENTIAL
126
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
common channel signaling (CCS) from up to 28 T1s or 21 E1s. The H-MVIP interfaces use common clocks, CMV8MCLK and CMVFPC, and frame pulse, CMVFPB, for synchronization. The three ingress H-MVIP interfaces operate independently except that using any one of these forces the T1 or E1 framer to operate in synchronous mode, meaning that elastic stores are used. Seven H-MVIP data signals, MVID[1:7], share pins with serial PCM data outputs, ID[x], to provide H-MVIP access for up to 672 data channels. The H-MVIP mapping is fixed such that each group of four nearest neighbor T1 or E1 links make up the individual 8.192Mb/s H-MVIP signal. The multiplexed data input is shared with the lowest numbered T1 or E1 serial PCM link in the bundle, for example MViD[2] combines the DS0s or timeslots of ID[5,6,7,8] and is pin multiplexed with ID[5]. This mode is selected when the SYSOPT[2:0] bits in the Global Configuration register are set to H-MVIP. A separate H-MVIP interface consisting of seven pins is for access to the channel associated signaling for all of the 672 data channels. The CAS is time division multiplexed exactly the same way as the data channels and is synchronized with the H-MVIP data channels. Over a T1 or E1 multi-frame the four CAS bits per channel are repeated with each data byte. Four stuff bits are used to pad each CAS nibble (ABCD bits) out to a full byte in synchronization with each data byte. The ingress CAS H-MVIP interface, CASID[1:7], is multiplexed with seven serial PCM ingress data pins, ID[2,6,10,14,18,22,26]. The CAS H-MVIP interface can be used in parallel with the SBI Drop bus as an alternative method for accessing the CAS bits while data transfer occurs over the SBI bus. This is selected when the SYSOPT[2:0] bits in the Global Configuration register are set to "SBI Interface with CAS or CCS H-MVIP Interface" and the ICCSSEL bit in the T1/E1 Ingress Serial Interface Mode Select register is set to 0. A separate H-MVIP interface consisting of a single signal is used to time division multiplex the common channel signaling (CCS) for all T1s and E1s and additionally the V5 channels in E1 mode. The CCS H-MVIP interface, CCSID, is not multiplexed with any other pins. CCSID can be used in parallel with the Clock Slave:H-MVIP mode when SYSOPT[2:0] is set to "H-MVIP Interface" and the ICCSSEL bit in the T1/E1 Ingress Serial Interface Mode Select register is set to 1, a Clock Slave serial interface when SYSOPT[2:0] is set to "Serial Clock and Data Interface with CCS H-MVIP Interface", or the SBI Add bus when SYSOPT[2:0] is set to "SBI Interface with CAS or CCS H-MVIP Interface" and the ICCSSEL bit is set to 1.
PROPRIETARY AND CONFIDENTIAL
127
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
When accessing the CAS or CCS signaling via the H-MVIP interface in parallel with serial clock and data or SBI interfaces a receive signaling elastic store is used to adapt any timing differences between the data interface and the CAS or CCS H-MVIP interface.
Figure 30
ID[1:28] IFP[1:28] ICLK[1:28]
- Clock Slave: Serial Data and H-MVIP CCS
RECEIVER
Outputs Timed to ICLK[x]
ELST Elastic Store ISIF Ingress System Interface
FRAM Framer: Slip Buffer RAM FRMR Framer: Frame Alignment, Alarm Extraction RJAT Digital Jitter Attenuator
Receive Data[1:28] Receive CLK[1:28]
CCSID CMVFP CMVFPC CMV8MCLK
Inputs Timed to CMV8MCLK
When Clock Slave: H-MVIP mode is enabled, payload data may be extracted throught the ingress serial interface, while common channel signaling is extracted in parallel through the H-MVIP interface. The H-MVIP ingress interface multiplexes common channel signalling from up to 28 T1s or 21 E1s. The H-MVIP interfaces use common clocks, CMV8MCLK and CMVFPC, and frame pulse, CMVFPB, for synchronization. Common channel signaling over H-MVIP uses a Clock Slave serial interface, selected when SYSOPT[2:0] is set to "Serial Clock and Data Interface with CCS H-MVIP Interface". CCSID is a singal dedicated output pin, output relative to CMV8MCLK, used to time division multiplex the common channel signaling (CCS) for all T1s and E1s, and additionally the V5 channels in E1 mode. The ingress clock, ICLK[x], is a 1.544MHz or 2.048MHz clock generated from the 16.384MHz CMV8MCLK. (Note that in T1 mode, this clock does not divide down to T1 rate evenly, resulting in a gappy clock. The minimum period is 10 times that of CMV8MCLK.) ICLK[x] is pulsed for each bit in the 193 bit T1 or 256 bit E1 frame (i.e. NxDS0 controls are not applicable in this mode). Payload data on ED[x] is sampled by this clock. The egress frame alignment is indicated by TEMUX on EFP[x], again timed to ICLK[x]. Note that several of the serial PMC ingress data pins ID[x] are multiplexed with the ingress data H-MVIP interface. ID[1,5,9,13,17,21,25] share pins with the HMVIP data signals MVID[1:7]. ID[2,6,10,14,18,22,26] share pins with the H-
PROPRIETARY AND CONFIDENTIAL
128
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
MVIP CAS signals CASID[1:7]. Note also that in this mode, a receive signaling elastic store is used to adapt any timing differences between the data interface and the CCS H-MVIP interface.
9.40 Extract Scaleable Bandwidth Interconnect (EXSBI)
The Extract Scaleable Bandwidth Interconnect block demaps up to 28 1.544Mb/s links, 21 2.048Mb/s links or a single 44.736Mb/s link from the SBI shared bus. The 1.544Mb/s links can be unframed when used in a straight multiplexer or mapper application, or they can be T1 framed and channelized for insertion into the DS3 multiplex or SONET/SDH mapping. The 2.048Mb/s links can be unframed when used in a straight mapper application, or they can be E1 framed and channelized for insertion into the SONET/SDH mapping. The 44.736Mb/s link can also be unframed for mapping into SONET/SDH or it can be DS3 unchannelized when the TEMUX is used as a DS3 framer. All egress links extracted from the SBI bus can be timed from the source or from the TEMUX. When Timing is from the source the EXSBI commands the PISO to generate 1.544Mb/s, 2.048Mb/s or 44.736Mb/s clocks slaved to the arrival rate of the data or from timing link rate adjustments provided from the source and carried with the links over the SBI bus. The 1.544Mb/s clock is synthesized from the 19.44MHz reference clock, SREFCLK, by dividing the clock by either 12 or 13 in a fixed sequence that produces the nominal 1.544Mb/s rate. The 2.048Mb/s clock is synthesized from the 19.44MHz reference clock by dividing the clock by either 9 or 10 in a fixed sequence that produces the nominal 2.048Mb/s rate. Timing adjustments are made over 500uS intervals and are done by either advancing or retarding the phase or by adding or deleting a whole 1.544Mb/s or 2.048Mb/s clock cycle over the 500uS period. The 44.736Mb/s clock is synthesized from the 51.84MHz or 44.928MHz reference clock, CLK52M. Using either reference clock frequency, the 44.736Mb/s rate is generated by gapping the reference clock in a fixed way. Timing adjustments are performed by adding or deleting four clocks over the 500uS period. When the TEMUX is the SBI egress clock master for a link, clocks are sourced within the TEMUX. Based on buffer fill levels, the EXSBI sends link rate adjustment commands to the link source indicating that it should send one additional or one fewer bytes of data during the next 500uS interval. Failure of the source to respond to these commands will ultimately result in overflows or underflows which can be configured to generate per link interrupts. Channelized T1s extracted from the SBI bus optionally have the channel associated signaling (CAS) bits explicitly defined and carried in parallel with the
PROPRIETARY AND CONFIDENTIAL
129
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
DS0s, but only if the SBI interface is configured for synchronous mode operation.
9.41 Insert Scaleable Bandwidth Interconnect (INSBI)
The Insert Scaleable Bandwidth Interconnect block maps up to 28 1.544Mb/s links, 21 2.048Mb/s links or a single 44.736Mb/s link into the SBI shared bus. The 1.544Mb/s links can be unframed when sourced directly from the DS3 multiplexer or SONET/SDH mapper, or they can be T1 channelized when sourced by the T1 framers. The 2.048Mb/s links can be unframed when sourced directly from the SONET/SDH mapper, or they can be E1 channelized when sourced by the E1 framers. The 44.736Mb/s link can also be unframed when sourced directly from the DS3 interface or from the DS3 mapper. The 44.736Mb/s link can be an unchannelized DS3 when sourced from the DS3 framer. Links inserted into the SBI bus can be timed from the TEMUX or from the far end. The INSBI makes link rate adjustments by adding or deleting an extra byte of data over a 500uS interval based on buffer fill levels. Timing adjustments made by the INSBI are detected by the receiving SBI interface by explicit signals in the SBI bus structure. The INSBI optionally sends link rate information across the SBI bus. This information is used by the receiving SBI interface to create a recovered link clock which is based on small clock phase adjustments signaled by the INSBI. Channelized T1s inserted into the SBI bus optionally have the channel associated signaling (CAS) bits explicitly defined and carried in parallel with the DS0s or timeslots, but only if the SBI interface is configured for synchronous mode operation. When enabled for CAS insertion the INSBI takes a byte serial stream of CAS bits from the SBISIPO and inserts them into the SBI bus structure.
9.42 Scaleable Bandwidth Interconnect PISO (SBIPISO)
The Scaleable Bandwidth Interconnect Parallel to Serial converter (SBIPISO) generates up to 28 T1s, 21 E1s or a DS3 serial clock and data signals from the byte serial stream provided by the Extract SBI block. The generated clock rate can be controlled with commands from the EXSBI. In clock slave mode the generated clock will be increased or decreased in small increments based on FIFO fill levels within the EXSBI or directly with clock rate commands from the far end device who is mastering the clock across the SBI bus. In clock master mode the SBIPISO controls the bit rate by accepting data from the EXSBI at the rate of the individual T1, E1 or DS3 clocks sourced into it.
PROPRIETARY AND CONFIDENTIAL
130
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
In addition the SBIPISO generates serial CAS signaling streams, frame pulses and multiframe pulses for all T1s, E1s and DS3.
9.43 Scaleable Bandwidth Interconnect SIPO (SBISIPO)
The Scaleable Bandwidth Interconnect Serial to Parallel converter (SBISIPO) sinks up to 28 T1s, 21 E1s or a DS3 serial clock and data signals and generates a byte serial stream to the Insert SBI block. The SBISIPO measures the serial clock against the SBI reference clock and sends this information to the INSBI block and in turn across the SBI bus to the clock generation slave, SBIPISO. In this way an accurate representation of the input clock rate is communicated across the SBI bus. In addition the SBISIPO generates byte serial streams from serial CAS signaling signals, frame pulses and multiframe pulses for all T1s, E1s and DS3.
9.44 JTAG Test Access Port
The JTAG Test Access Port block provides JTAG support for boundary scan. The standard JTAG EXTEST, SAMPLE, BYPASS, IDCODE and STCTEST instructions are supported. The TEMUX identification code is 083150CD hexadecimal.
9.45 Microprocessor Interface
The Microprocessor Interface Block provides normal and test mode registers, the interrupt logic, and the logic required to connect to the Microprocessor Interface. The normal mode registers are required for normal operation, and test mode registers are used to enhance the testability of the TEMUX. The Register Memory Map in Table 10 shows where the normal mode registers are accessed. The registers are organized so that backward software compatibility with existing PMC devices is optimized. The resulting register organization splits into sections: Master configuration registers, 28 sets of T1/E1 Framer registers, DS3 M13 multiplexing registers, SONET/SDH mapping registers and SBI registers. On power up reset the TEMUX defaults to 28 T1 framers multiplexed into the M13 multiplexer using the DS3 M23 multiplex format. For proper operation some register configuration is necessary. System side access defaults to the SBI bus without any tributaries enabled which will leave the SBI Drop bus tristated. By default interrupts will not be enabled, automatic alarm generation is disabled, a dual rail DS3 LIU interface is expected and an external transmit reference clock is required.
PROPRIETARY AND CONFIDENTIAL
131
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Table 10 Address
- Register Memory Map Register
0000H 0001H 0002H 0003H 0004H 0005H 0006H 0007H000FH 00010H 0011H 0012H 0013H 0014H 0015H001FH 0020H 0021H 0022H 0023H 0024H 0025H 0026H 0027H 0028H
Global Reset Global Configuration Revision/Global PMON Update Master Recovered Clock#1/Reference Clock Select Recovered Clock#2 Select Master Common Egress Serial and H-MVIP Interface Configuration Master Common Ingress Serial and H-MVIP Interface Configuration Reserved Master Clock Monitor #1 Master Clock Monitor #2 Master Clock Monitor #3 Master Clock Monitor #4 Master Clock Monitor #5 Reserved Master Interrupt Source Master Interrupt Status T1/E1 #1-8 Master Interrupt Status T1/E1 #9-16 Master Interrupt Status T1/E1 #17-24 Master Interrupt Status T1 #25-28 Master Interrupt Status SDH Master Interrupt Status Source SBI Reserved Master Interrupt Status DS3
PROPRIETARY AND CONFIDENTIAL
132
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Address
Register
0029H 002AH 002BH 002CH 002DH 002EH 002FH 0030H007FH
0080H00FFH
Master Interrupt Status DS2 Master Interrupt Status MX12 Reserved Master SBIDET0 Collision Detect LSB Master SBIDET0 Collision Detect MSB Master SBIDET1 Collision Detect LSB Master SBIDET1 Collision Detect MSB Reserved
T1/E1 Framer Slice #1
0080H 0081H 0082H 0083H 0084H 0085H 0086H 0087H 0088H 0089H 008AH 008BH 008CH 008DH 008EH 008FH 0090H 0091H
T1/E1 Master Configuration Reserved T1/E1 Receive Options T1/E1 Alarm Configuration T1/E1 Egress Line Interface Configuration T1/E1 Master Ingress Serial Interface Mode Select T1/E1 Master Egress Serial Interface Mode Select T1/E1 Master Ingress Parity and Alarm Enable T1/E1 Master Egress Parity Enable T1/E1 Master Serial Interface Configuration T1/E1 Transmit Framing and Bypass Options T1/E1 Interrupt Source #1 T1/E1 Interrupt Source #2 T1/E1 Diagnostics T1/E1 PRBS Positioning and HDLC Control Reserved RJAT Interrupt Status RJAT Reference Clock Divisor N1 Control
PROPRIETARY AND CONFIDENTIAL
133
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Address
Register
0092H 0093H 0094H 0095H 0096H 0097H 0098H 0099H 009AH 009BH 009CH 009DH 009EH009FH 00A0H 00A1H 00A2H00A7H 00A8H 00A9H 00AAH00AFH 00B0H 00B1H 00B2H 00B3H 00B4H 00B5H 00B6H
RJAT Output Clock Divisor N2 Control RJAT Configuration TJAT Interrupt Status TJAT Reference Clock Divisor N1 Control TJAT Output Clock Divisor N2 Control TJAT Configuration RX-ELST Configuration RX-ELST Interrupt Enable/Status RX-ELST Idle Code RX-ELST Reserved TX-ELST Configuration TX-ELST Interrupt Enable/Status TX-ELST Reserved RXCE Ingress Data Link Control RXCE Ingress Data Link Bit Select RXCE Reserved TXCI Egress Data Link Control TXCI Egress Data Link Bit Select TXCI Reserved RPSC Configuration RPSC P Access Status RPSC Channel Indirect Address/Control RPSC Channel Indirect Data Buffer TPSC Configuration TPSC P Access Status TPSC Channel Indirect Address/Control
PROPRIETARY AND CONFIDENTIAL
134
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Address
Register
00B7H 00B8H 00B9H 00BAH 00BBH 00BCH 00BDH 00BEH 00BFH 00C0H 00C1H 00C2H 00C3H 00C4H 00C5H 00C6H00C7H 00C8H 00C9H 00CAH 00CBH 00CCH 00CDH 00CEH00CFH 00D0H 00D1H 00D2H 00D3H
TPSC Channel Indirect Data Buffer PMON Interrupt Enable/Status PMON Framing Bit Error Count PMON OOF/COFA/Far End Block Error Count (LSB) PMON OOF/COFA/Far End Block Error Count (MSB) PMON Bit Error/CRCE Count (LSB) PMON Bit Error/CRCE Count (MSB) PMON Reserved PMON Reserved RDLC Configuration RDLC Interrupt Control RDLC Status RDLC Data RDLC Primary Address Match RDLC Secondary Address Match Reserved TDPR Configuration TDPR Upper Transmit Threshold TDPR Lower Transmit Threshold TDPR Interrupt Enable TDPR Interrupt Status/UDR Clear TDPR Transmit Data Reserved PRBS Generator/Checker Control PRBS Checker Interrupt Enable/Status PRBS Pattern Select PRBS Reserved
PROPRIETARY AND CONFIDENTIAL
135
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Address
Register
00D4H 00D5H 00D6H 00D7H 00D8H 00D9H 00DAH 00DBH 00DCH 00DDH 00DEH 00DFH 00E0H 00E1H 00E2H 00E3H 00E4H 00E5H 00E6H 00E7H 00E8H 00E9H 00EAH00EBH 00ECH 00EDH 00EEH
PRBS Error Count Register #1 PRBS Error Count Register #2 PRBS Error Count Register #3 PRBS Reserved SIGX Configuration/Change of Signaling State SIGX Channel Indirect Status/Change of Signaling State SIGX Channel Indirect Address/Control/ Change of Signaling State SIGX Channel Indirect Data Buffer/Change of Signaling State RX-SIG-ELST Configuration RX- SIG-ELST Interrupt Enable/Status RX- SIG-ELST Idle Code RX- SIG-ELST Reserved T1 ALMI Configuration T1 ALMI Interrupt Enable T1 ALMI Interrupt Status T1 ALMI Alarm Detection Status T1 XBOC Control T1 XBOC Code T1 RBOC Enable T1 RBOC Code Status T1 XBAS Configuration T1 XBAS Alarm Transmit T1 XBAS Reserved T1 FRMR Configuration T1 FRMR Interrupt Enable T1 FRMR Interrupt Status
PROPRIETARY AND CONFIDENTIAL
136
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Address
Register
00EFH 00F0H 00F1H 00F2H 00F3H 00F4H 00F5H 00F6H 00F7H 00E0H 00E1H 00E2H 00E3H 00E4H 00E5H 00E6H 00E7H 00E8H 00E9H 00EAH 00EBH 00ECH 00EDH 00EEH 00EFH 00F0H 00F1H 00F2H
T1 FRMR Reserved T1 APRM Configuration/Control T1 APRM Manual Load T1 APRM Interrupt Status T1 APRM One Second Content Octet 2 T1 APRM One Second Content Octet 3 T1 APRM One Second Content Octet 4 T1 APRM One Second Content MSB (Octet 5) T1 APRM One Second Content LSB (Octet 6) E1 FRMR Frame Alignment Options E1 FRMR Maintenance Mode Options E1 FRMR Framing Status Interrupt Enable E1 FRMR Maintenance/Alarm Status Interrupt Enable E1 FRMR Framing Status Interrupt Indication E1 FRMR Maintenance/Alarm Status Interrupt Indication E1 FRMR Framing Status E1 FRMR Maintenance/Alarm Status E1 FRMR International/National Bits E1 FRMR CRC Error Count - LSB E1 FRMR CRC Error Count - MSB E1 FRMR National Bit Codeword Interrupt Enables E1 FRMR National Bit Codeword Interrupts E1 FRMR National Bit Codewords E1 FRMR Frame Pulse/Alarm Interrupt Enables E1 FRMR Frame Pulse/Alarm Interrupt E1 TRAN Configuration E1 TRAN Transmit Alarm/Diagnostic Control E1 TRAN International Control
PROPRIETARY AND CONFIDENTIAL
137
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Address
Register
00F3H 00F4H 00F5H 00F6H 00F7H 00F8H00FFH
0100H017FH 0180H01FFH 0200H027FH 0280H02FFH 0300H037FH 0380H03FFH 0400H047FH 0480H04FFH 0500H057FH 0580H05FFH 0600H067FH 0680H06FFH
E1 TRAN Extra Bits Control E1 TRAN Interrupt Enable E1 TRAN Interrupt Status E1 TRAN National Bit Codeword Select E1 TRAN National Bit Codeword Reserved
T1/E1 Framer Slice #2 T1/E1 Framer Slice #3 T1/E1 Framer Slice #4 T1/E1 Framer Slice #5 T1/E1 Framer Slice #6 T1/E1 Framer Slice #7 T1/E1 Framer Slice #8 T1/E1 Framer Slice #9 T1/E1 Framer Slice #10 T1/E1 Framer Slice #11 T1/E1 Framer Slice #12 T1/E1 Framer Slice #13
PROPRIETARY AND CONFIDENTIAL
138
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Address 0700H077FH 0780H07FFH 0800H087FH 0880H08FFH 0900H097FH 0980H09FFH 0A00H0A7FH 0A80H0AFFH 0B00H0B7FH
Register T1/E1 Framer Slice #14 T1/E1 Framer Slice #15 T1/E1 Framer Slice #16 T1/E1 Framer Slice #17 T1/E1 Framer Slice #18 T1/E1 Framer Slice #19 T1/E1 Framer Slice #20 T1/E1 Framer Slice #21 T1 Framer Slice #22
0B00H 0B01H 0B02H 0B03H 0B04H 0B05H 0B06H 0B07H 0B08H 0B09H 0B0AH 0B0BH 0B0CH
T1/E1 Master Configuration Reserved T1/E1 Receive Options T1/E1 Ingress Line Interface Configuration T1/E1 Egress Line Interface Configuration T1/E1 Master Ingress Serial Interface Mode Select T1/E1 Master Egress Serial Interface Mode Select T1/E1 Master Ingress Parity and Alarm Enable T1/E1 Master Egress Parity Enable T1/E1 Master Serial Interface Configuration T1/E1 Transmit Framing and Bypass Options T1/E1 Interrupt Source #1 T1/E1 Interrupt Source #2
PROPRIETARY AND CONFIDENTIAL
139
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Address
Register
0B0DH 0B0EH 0B0FH 0B10H 0B11H 0B12H 0B13H 0B14H 0B15H 0B16H 0B17H 0B18H 0B19H 0B1AH 0B1BH 0B1CH 0B1DH 0B1EH0B1FH 0B20H 0B21H 0B22H0B27H 0B28H 0B29H 0B2AH0B2FH 0B30H 0B31H
T1/E1 Diagnostics T1/E1 PRBS Positioning and HDLC Control Reserved RJAT Interrupt Status RJAT Reference Clock Divisor N1 Control RJAT Output Clock Divisor N2 Control RJAT Configuration TJAT Interrupt Status TJAT Reference Clock Divisor N1 Control TJAT Output Clock Divisor N2 Control TJAT Configuration RX-ELST Configuration RX-ELST Interrupt Enable/Status RX-ELST Idle Code RX-ELST Reserved TX-ELST Configuration TX-ELST Interrupt Enable/Status TX-ELST Reserved RXCE Ingress Data Link Control RXCE Ingress Data Link Bit Select RXCE Reserved TXCI Egress Data Link Control TXCI Egress Data Link Bit Select TXCI Reserved RPSC Configuration RPSC P Access Status
PROPRIETARY AND CONFIDENTIAL
140
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Address
Register
0B32H 0B33H 0B34H 0B35H 0B36H 0B37H 0B38H 0B39H 0B3AH 0B3BH 0B3CH 0B3DH 0B3EH 0B3FH 0B40H 0B41H 0B42H 0B43H 0B44H 0B45H 0B46H0B47H 0B48H 0B49H 0B4AH 0B4BH 0B4CH 0B4DH
RPSC Channel Indirect Address/Control RPSC Channel Indirect Data Buffer TPSC Configuration TPSC P Access Status TPSC Channel Indirect Address/Control TPSC Channel Indirect Data Buffer PMON Interrupt Enable/Status PMON Framing Bit Error Count PMON OOF/COFA/Far End Block Error Count (LSB) PMON OOF/COFA/Far End Block Error Count (MSB) PMON Bit Error/CRCE Count (LSB) PMON Bit Error/CRCE Count (MSB) PMON Reserved PMON Reserved RDLC Configuration RDLC Interrupt Control RDLC Status RDLC Data RDLC Primary Address Match RDLC Secondary Address Match Reserved TDPR Configuration TDPR Upper Transmit Threshold TDPR Lower Transmit Threshold TDPR Interrupt Enable TDPR Interrupt Status/UDR Clear TDPR Transmit Data
PROPRIETARY AND CONFIDENTIAL
141
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Address
Register
0B4EH0B4FH 0B50H 0B51H 0B52H 0B53H 0B54H 0B55H 0B56H 0B57H 0B58H 0B59H 0B5AH 0B5BH 0B5CH 0B5DH 0B5EH 0B5FH 0B60H 0B61H 0B62H 0B63H 0B64H 0B65H 0B66H 0B67H 0B68H
Reserved PRBS Generator/Checker Control PRBS Checker Interrupt Enable/Status PRBS Pattern Select PRBS Reserved PRBS Error Count Register #1 PRBS Error Count Register #2 PRBS Error Count Register #3 PRBS Reserved SIGX Configuration/Change of Signaling State SIGX Channel Indirect Status/Change of Signaling State SIGX Channel Indirect Address/Control/ Change of Signaling State SIGX Channel Indirect Data Buffer/Change of Signaling State RX-SIG-ELST Configuration RX- SIG-ELST Interrupt Enable/Status RX- SIG-ELST Idle Code RX- SIG-ELST Reserved T1 ALMI Configuration T1 ALMI Interrupt Enable T1 ALMI Interrupt Status T1 ALMI Alarm Detection Status T1 XBOC Control T1 XBOC Code T1 RBOC Enable T1 RBOC Code Status T1 XBAS Configuration
PROPRIETARY AND CONFIDENTIAL
142
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Address
Register
0B69H 0B6AH0B6BH 0B6CH 0B6DH 0B6EH 0B6FH 0B70H 0B71H 0B72H 0B73H 0B74H 0B75H 0B76H 0B77H 0B78H0B7FH
0B80H0BFFH 0C00H0C7FH 0C80H0CFFH 0D00H0D7FH 0D80H0DFFH 0E00H0E7FH
T1 XBAS Alarm Transmit T1 XBAS Reserved T1 FRMR Configuration T1 FRMR Interrupt Enable T1 FRMR Interrupt Status T1 FRMR Reserved T1 APRM Configuration/Control T1 APRM Manual Load T1 APRM Interrupt Status T1 APRM One Second Content Octet 2 T1 APRM One Second Content Octet 3 T1 APRM One Second Content Octet 4 T1 APRM One Second Content MSB (Octet 5) T1 APRM One Second Content LSB (Octet 6) Reserved
T1 Framer Slice #23 T1 Framer Slice #24 T1 Framer Slice #25 T1 Framer Slice #26 T1 Framer Slice #27 T1 Framer Slice #28
0E80H0FFFH
Reserved
PROPRIETARY AND CONFIDENTIAL
143
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Address 1000H10FFH
Register DS3 FRAMER and M13 Multiplexer
1000H 1001H 1002H 1003H 1004H 1005H 1006H 1007H 1008H 1009H 100AH100BH 100CH 100DH 100EH 100FH 1010H 1011H 1012H 1013H 1014H 1015H 1016H 1017H 1018H 1019H 101AH
DS3 Master Reset DS3 Master Data Source DS3 Master Unchannelized Interface Options DS3 Master Transmit Line Options DS3 Master Receive Line Options DS3 Master Alarm Enable DS2 Master Alarm Enable / DS3 Network Requirement Bit Reserved DS3 TRAN Configuration DS3 TRAN Diagnostic DS3 TRAN Reserved DS3 FRMR Configuration DS3 FRMR Interrupt Enable/Additional Configuration DS3 FRMR Interrupt Status DS3 FRMR Status DS3 PMON Performance Meters DS3 PMON Interrupt Enable/Status DS3 PMON Reserved DS3 PMON Reserved DS3 PMON Line Code Violation Event Count LSB DS3 PMON Line Code Violation Event Count MSB DS3 PMON Framing Bit Error Event Count LSB DS3 PMON Framing Bit Error Event Count MSB DS3 PMON Excessive Zeros LSB DS3 PMON Excessive Zeros MSB DS3 PMON Parity Error Event Count LSB
PROPRIETARY AND CONFIDENTIAL
144
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Address
Register
101BH 101CH 101DH 101EH 101FH 1020H 1021H 1022H 1023H 1024H 1025H 1026H1027H 1028H 1029H 102AH 102BH 102CH 102DH 102EH102FH 1030H 1031H 1032H 1033H 1034H 1035H1037H 1038H
DS3 PMON Parity Error Event Count MSB DS3 PMON Path Parity Error Event Count LSB DS3 PMON Path Parity Error Event Count MSB DS3 PMON FEBE Event Count LSB DS3 PMON FEBE Event Count MSB DS3 TDPR Configuration DS3 TDPR Upper Transmit Threshold DS3 TDPR Lower Interrupt Threshold DS3 TDPR Interrupt Enable DS3 TDPR Interrupt Status/UDR Clear DS3 TDPR Transmit Data DS3 TDPR Reserved DS3 RDLC Configuration DS3 RDLC Interrupt Control DS3 RDLC Status DS3 RDLC Data DS3 RDLC Primary Address Match DS3 RDLC Secondary Address Match DS3 RDLC Reserved PRGD Control PRGD Interrupt Enable/Status PRGD Length PRGD Tap PRGD Error Insertion PRGD Reserved PRGD Pattern Insertion Register #1
PROPRIETARY AND CONFIDENTIAL
145
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Address
Register
1039H 103AH 103BH 103CH 103DH 103EH 103FH 1040H 1041H 1042H 1043H 1044H 1045H 1046H 1047H 1048H 1049H 104AH 104BH 104CH105FH 1060H 1061H 1062H 1063H 1064H 1065H 1066H
PRGD Pattern Insertion Register #2 PRGD Pattern Insertion Register #3 PRGD Pattern Insertion Register #4 PRGD Pattern Detector Register #1 PRGD Pattern Detector Register #2 PRGD Pattern Detector Register #3 PRGD Pattern Detector Register #4 MX23 Configuration MX23 Demux AIS Insert MX23 Mux AIS Insert MX23 Loopback Activate MX23 Loopback Request Insert MX23 Loopback Request Detect MX23 Loopback Request Interrupt MX23 Reserved FEAC XBOC Control FEAC XBOC Code FEAC RBOC Configuration/Interrupt Enable FEAC RBOC Interrupt Status Reserved DS2 FRMR #1 Configuration DS2 FRMR #1 Interrupt Enable DS2 FRMR #1 Interrupt Status DS2 FRMR #1 Status DS2 FRMR #1 Monitor Interrupt Enable/Status DS2 FRMR #1 FERR Count DS2 FRMR #1 PERR Count (LSB)
PROPRIETARY AND CONFIDENTIAL
146
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Address
Register
1067H 1068H106FH 1070H 1071H 1072H 1073H 1074H 1075H1077H 1078H107FH 1080H1087H 1088H108FH 1090H1097H 1098H109FH 10A0H10A7H 10A8H10AFH 10B0H10B7H 10B8H10BFH 10C0H10C7H 10C8H10CFH
DS2 FRMR #1 PERR Count (MSB) Reserved MX12 #1 Configuration and Control MX12 #1 Loopback Code Select MX12 #1 Mux/Demux AIS Insert MX12 #1 Loopback Activate MX12 #1 Loopback Interrupt MX12 #1 Reserved Reserved DS2 FRMR #2 Registers Reserved MX12 #2 Registers Reserved DS2 FRMR #3 Registers Reserved MX12 #3 Registers Reserved DS2 FRMR #4 Registers Reserved
PROPRIETARY AND CONFIDENTIAL
147
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Address
Register
10D0H10D7H 10D8H10DFH 10E0H10E7H 10E8H10EFH 10F0H10F7H 10F8H10FFH 1100H1107H 1108H110FH 1110H1117H 1118H111FH 1120H1127H 1128H112FH 1130H1137H 1138H11FFH
1200H16FFH
MX12 #4 Registers Reserved DS2 FRMR #5 Registers Reserved MX12 #5 Registers Reserved DS2 FRMR #6 Registers Reserved MX12 #6 Registers Reserved DS2 FRMR #7 Registers Reserved MX12 #7 Registers Reserved
SONET/SDH Mapper and Demapper
1200H 1201H 1202H
SONET/SDH Master Configuration SONET/SDH Master Ingress Configuration SONET/SDH Master Egress Configuration
PROPRIETARY AND CONFIDENTIAL
148
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Address
Register
1203H 1204H 1205H 1206H 1207H 1208H 1209H 120AH 120BH 120CH121FH 1220H123FH 1240H 1241H 1242H 1243H 1244H 1245H 1246H 1247H 1248H 1249H 124AH 124BH 124CH 124DH
SONET/SDH Master Ingress VTPP Configuration SONET/SDH Master Egress VTPP Configuration SONET/SDH Master RTOP Configuration SONET/SDH Master Tributary Alarm AIS Control SONET/SDH Master Tributary Remote Defect Indication Control SONET/SDH Master Tributary Auxiliary Remote Defect Indication Control SONET/SDH Master DS3 Clock Generation Control SONET/SDH Master Loopback Control SONET/SDH Telecom Bus Signal Monitor, Accumulation Trigger SONET/SDH Reserved Ingress PISO Reserved VTPP Ingress, TU #1 in TUG2 #1, Configuration and Status VTPP Ingress, TU #1 in TUG2 #1, Alarm Status VTPP Ingress, TU #1 in TUG2 #2, Configuration and Status VTPP Ingress, TU #1 in TUG2 #2, Alarm Status VTPP Ingress, TU #1 in TUG2 #3, Configuration and Status VTPP Ingress, TU #1 in TUG2 #3, Alarm Status VTPP Ingress, TU #1 in TUG2 #4, Configuration and Status VTPP Ingress, TU #1 in TUG2 #4, Alarm Status VTPP Ingress, TU #1 in TUG2 #5, Configuration and Status VTPP Ingress, TU #1 in TUG2 #5, Alarm Status VTPP Ingress, TU #1 in TUG2 #6, Configuration and Status VTPP Ingress, TU #1 in TUG2 #6, Alarm Status VTPP Ingress, TU #1 in TUG2 #7, Configuration and Status VTPP Ingress, TU #1 in TUG2 #7, Alarm Status
PROPRIETARY AND CONFIDENTIAL
149
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Address
Register
124EH 124FH 1250H125DH 125EH 125FH 1260H126DH 126EH 126FH 1270H127DH 127EH 127FH 1280H 1281H 1282H 1283H 1284H 1285H 1286H 1287H 1288H128EH 128FH 1290H1296H
VTPP Ingress, TU #1 in TUG2 #1 to TUG2 #7, LOP Interrupt VTPP Ingress, TU #1 in TUG2 #1 to TUG2 #7, AIS Interrupt VTPP Ingress, TU #2 in TUG2 #1 to TUG2 #7, Configuration and Status/Alarm Status VTPP Ingress, TU #2 in TUG2 #1 to TUG2 #7, LOP Interrupt VTPP Ingress, TU #2 in TUG2 #1 to TUG2 #7 AIS Interrupt VTPP Ingress, TU #3 in TUG2 #1 to TUG2 #7, Configuration and Status/Alarm Status VTPP Ingress, TU #3 in TUG2 #1 to TUG2 #7, LOP Interrupt VTPP Ingress, TU #3 in TUG2 #1 to TUG2 #7, AIS Interrupt VTPP Ingress, TU #4 in TUG2 #1 to TUG2 #7, Configuration and Status/Alarm Status VTPP Ingress, TU #4 in TUG2 #1 to TUG2 #7, LOP Interrupt VTPP Ingress, TU #4 in TUG2 #1 to TUG2 #7, AIS Interrupt RTDM TU #1 in TUG2 #1 of TUG3 #1, Control RTDM TU #1 in TUG2 #2 of TUG3 #1, Control RTDM TU #1 in TUG2 #3 of TUG3 #1, Control RTDM TU #1 in TUG2 #4 of TUG3 #1, Control RTDM TU #1 in TUG2 #5 of TUG3 #1, Control RTDM TU #1 in TUG2 #6 of TUG3 #1, Control RTDM TU #1 in TUG2 #7 of TUG3 #1, Control RTDM Reserved RTDM TU #2 in TUG2 #1 to TUG#7 of TUG3 #1, Control RTDM Reserved RTDM TU #3 in TUG2 #1 to TUG#7 of TUG3 #1, Control
PROPRIETARY AND CONFIDENTIAL
150
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Address
Register
1297H 1298H129EH 129FH 12A0H12BEH 12BFH 12C0H12DEH 12DFH 12E0H 12E1H 12E2H 12E3H 12E4H 12E5H 12E6H 12E7H 12E8H 12E9H 12EAH 12EBH 12ECH12FFH 1300H 1301H 1302H 1303H 1304H
RTDM Reserved RTDM TU #4 in TUG2 #1 to TUG#7 of TUG3 #1, Control RTDM Reserved RTDM TUs #1-4, in TUG2s #1-7 of TUG3 #2, Control RTDM Reserved RTDM TUs #1-4, in TUG2s #1-7 of TUG3 #3, Control RTDM Reserved RTDM Pointer Justification Rate Control RTDM Reserved RTDM Time Switch Page Control RTDM Indirect Time Switch Tributary RAM Status and Control RTDM Indirect Time Switch Internal Link RTDM Indirect Time Switch Tributary RTDM Demap State Vector RAM Address RTDM Demap State Vector RAM Control and Data RTDM Demap Debug State Vector RAM Data RTDM Demap State Vector RAM Data RTDM Demap State Vector RAM Data RTDM Demap State Vector RAM Data Reserved RTOP TU #1 in TUG2 #1, Configuration RTOP TU #1 in TUG2 #1, Configuration and Alarm Status RTOP TU #1 in TUG2 #1, Expected Path Signal Label RTOP TU #1 in TUG2 #1, Accepted Path Signal Label RTOP TU #1 in TUG2 #1, BIP-2 Error Count LSB
PROPRIETARY AND CONFIDENTIAL
151
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Address
Register
1305H 1306H 1307H 1308H130FH 1310H1317H 1318H131FH 1320H1327H 1328H132FH 1330H1337H 1338H 1339H 133AH 133BH 133CH 133DH 133EH133FH 1340H1347H 1348H134FH 1350H1357H 1358H135FH
RTOP TU #1 in TUG2 #1, BIP-2 Error Count MSB RTOP TU #1 in TUG2 #1, FEBE Error Count LSB RTOP TU #1 in TUG2 #1, FEBE Error Count MSB RTOP TU #1 in TUG2 #2, Configuration and Status Registers RTOP TU #1 in TUG2 #3, Configuration and Status Registers RTOP TU #1 in TUG2 #4, Configuration and Status Registers RTOP TU #1 in TUG2 #5, Configuration and Status Registers RTOP TU #1 in TUG2 #6, Configuration and Status Registers RTOP TU #1 in TUG2 #7, Configuration and Status Registers RTOP TU #1 in TUG2 #1 to TUG2 #7, COPSL Interrupt RTOP TU #1 in TUG2 #1 to TUG2 #7, PSLM Interrupt RTOP TU #1 in TUG2 #1 to TUG2 #7, PSLU Interrupt RTOP TU #1 in TUG2 #1 to TUG2 #7, RDI Interrupt RTOP TU #1 in TUG2 #1 to TUG2 #7, RFI Interrupt RTOP TU #1 in TUG2 #1 to TUG2 #7, Inband Error Reporting Configuration RTOP Reserved RTOP TU #2 in TUG2 #1, Configuration and Status Registers RTOP TU #2 in TUG2 #2, Configuration and Status Registers RTOP TU #2 in TUG2 #3, Configuration and Status Registers RTOP TU #2 in TUG2 #4, Configuration and Status Registers
PROPRIETARY AND CONFIDENTIAL
152
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Address
Register
1360H1367H 1368H136FH 1370H1377H 1378H 1379H 137AH 137BH 137CH 137DH 137EH137FH 1380H1387H 1388H138FH 1390H1397H 1398H139FH 13A0H13A7H 13A8H13AFH 13B0H13B7H 13B8H 13B9H 13BAH
RTOP TU #2 in TUG2 #5, Configuration and Status Registers RTOP TU #2 in TUG2 #6, Configuration and Status Registers RTOP TU #2 in TUG2 #7, Configuration and Status Registers RTOP TU #2 in TUG2 #1 to TUG2 #7, COPSL Interrupt RTOP TU #2 in TUG2 #1 to TUG2 #7, PSLM Interrupt RTOP TU #2 in TUG2 #1 to TUG2 #7, PSLU Interrupt RTOP TU #2 in TUG2 #1 to TUG2 #7, RDI Interrupt RTOP TU #2 in TUG2 #1 to TUG2 #7, RFI Interrupt RTOP TU #2 in TUG2 #1 to TUG2 #7, Inband Error Reporting Configuration RTOP Reserved RTOP TU #3 in TUG2 #1, Configuration and Status Registers RTOP TU #3 in TUG2 #2, Configuration and Status Registers RTOP TU #3 in TUG2 #3, Configuration and Status Registers RTOP TU #3 in TUG2 #4, Configuration and Status Registers RTOP TU #3 in TUG2 #5, Configuration and Status Registers RTOP TU #3 in TUG2 #6, Configuration and Status Registers RTOP TU #3 in TUG2 #7, Configuration and Status Registers RTOP TU #3 in TUG2 #1 to TUG2 #7, COPSL Interrupt RTOP TU #3 in TUG2 #1 to TUG2 #7, PSLM Interrupt RTOP TU #3 in TUG2 #1 to TUG2 #7, PSLU Interrupt
PROPRIETARY AND CONFIDENTIAL
153
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Address
Register
13BBH 13BCH 13BDH 13BEH13BFH 13C0H13C7H 13C8H13CFH 13D0H13D7H 13D8H13DFH 13E0H13E7H 13E8H13EFH 13F0H13F7H 13F8H 13F9H 13FAH 13FBH 13FCH 13FDH 13FEH13FFH 1400H 1401H 1402H
RTOP TU #3 in TUG2 #1 to TUG2 #7, RDI Interrupt RTOP TU #3 in TUG2 #1 to TUG2 #7, RFI Interrupt RTOP TU #3 in TUG2 #1 to TUG2 #7, Inband Error Reporting Configuration RTOP Reserved RTOP TU #4 in TUG2 #1, Configuration and Status Registers RTOP TU #4 in TUG2 #2, Configuration and Status Registers RTOP TU #4 in TUG2 #3, Configuration and Status Registers RTOP TU #4 in TUG2 #4, Configuration and Status Registers RTOP TU #4 in TUG2 #5, Configuration and Status Registers RTOP TU #4 in TUG2 #6, Configuration and Status Registers RTOP TU #4 in TUG2 #7, Configuration and Status Registers RTOP TU #4 in TUG2 #1 to TUG2 #7, COPSL Interrupt RTOP TU #4 in TUG2 #1 to TUG2 #7, PSLM Interrupt RTOP TU #4 in TUG2 #1 to TUG2 #7, PSLU Interrupt RTOP TU #4 in TUG2 #1 to TUG2 #7, RDI Interrupt RTOP TU #4 in TUG2 #1 to TUG2 #7, RFI Interrupt RTOP TU #4 in TUG2 #1 to TUG2 #7, InBand Error Reporting Configuration RTOP Reserved VTPP Egress, TU #1 in TUG2 #1, Configuration and Status VTPP Egress, TU #1 in TUG2 #1, Alarm Status VTPP Egress, TU #1 in TUG2 #2, Configuration and Status
PROPRIETARY AND CONFIDENTIAL
154
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Address
Register
1403H 104H 1405H 1406H 1407H 1408H 1409H 140AH 140BH 140CH 140DH 140EH 140FH 1410H141DH 141EH 141FH 1420H142DH 142EH 142FH 1430H143DH 143EH 143FH 1440H147FH
VTPP Egress, TU #1 in TUG2 #2, Alarm Status VTPP Egress, TU #1 in TUG2 #3, Configuration and Status VTPP Egress, TU #1 in TUG2 #3, Alarm Status VTPP Egress, TU #1 in TUG2 #4, Configuration and Status VTPP Egress, TU #1 in TUG2 #4, Alarm Status VTPP Egress, TU #1 in TUG2 #5, Configuration and Status VTPP Egress, TU #1 in TUG2 #5, Alarm Status VTPP Egress, TU #1 in TUG2 #6, Configuration and Status VTPP Egress, TU #1 in TUG2 #6, Alarm Status VTPP Egress, TU #1 in TUG2 #7, Configuration and Status VTPP Egress, TU #1 in TUG2 #7, Alarm Status VTPP Egress, TU #1 in TUG2 #1 to TUG2 #7, LOP Interrupt VTPP Egress, TU #1 in TUG2 #1 to TUG2 #7, AIS Interrupt VTPP Egress, TU #2 in TUG2 #1 to TUG2 #7, Configuration and Status/Alarm Status VTPP Egress, TU #2 in TUG2 #1 to TUG2 #7, LOP Interrupt VTPP Egress, TU #2 in TUG2 #1 to TUG2 #7 AIS Interrupt VTPP Egress, TU #3 in TUG2 #1 to TUG2 #7, Configuration and Status/Alarm Status VTPP Egress, TU #3 in TUG2 #1 to TUG2 #7, LOP Interrupt VTPP Egress, TU #3 in TUG2 #1 to TUG2 #7, AIS Interrupt VTPP Egress, TU #4 in TUG2 #1 to TUG2 #7, Configuration and Status/Alarm Status VTPP Egress, TU #4 in TUG2 #1 to TUG2 #7, LOP Interrupt VTPP Egress, TU #4 in TUG2 #1 to TUG2 #7, AIS Interrupt Reserved
PROPRIETARY AND CONFIDENTIAL
155
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Address
Register
1480H 1481H 1482H 1483H 1484H 1485H 1486H 1487H 1488H148EH 148FH 1490H1496H 1497H 1498H149EH 149FH 14A0H14BFH 14C0H14DFH 14E0H 14E 1H 14E2H 14E3H 14E4H14E7H
TRAP TU #1 in TUG2 #1 of TU3 #1, Control TRAP TU #1 in TUG2 #2 of TU3 #1, Control TRAP TU #1 in TUG2 #3 of TU3 #1, Control TRAP TU #1 in TUG2 #4 of TU3 #1, Control TRAP TU #1 in TUG2 #5 of TU3 #1, Control TRAP TU #1 in TUG2 #6 of TU3 #1, Control TRAP TU #1 in TUG2 #7 of TU3 #1, Control TRAP TU #1 in TUG2 #1 to TUG2 #7 of TUG3 #1, Egress AIS Control TRAP TU #2 in TUG2 #1 to TUG#7 of TU3 #1, Control TRAP TU#2 in TUG2 #1 to TUG2 #7 of TU3 #1, Egress AIS Control TRAP TU #3 in TUG2 #1 to TUG#7 of TU3 #1, Control TRAP TU#3 in TUG2 #1 to TUG2 #7 of TU3 #1, Egress AIS Control TRAP TU #4 in TUG2 #1 to TUG#7 of TU3 #1, Control TRAP TU#4 in TUG2 #1 to TUG2 #7 of TU3 #1, Egress AIS Control TRAP TUs #1 to 4 in TUG2s #1 to 7 of TUG3 #2, Control and Egress AIS Control TRAP TUs #1 to 4 in TUG2s #1 to 7 of TUG3 #3, Control and Egress AIS Control TRAP Indirect Remote Alarm Page Address TRAP Indirect Remote Alarm Tributary Address TRAP Indirect Datapath Tributary Data TRAP RDI Control TRAP Reserved
PROPRIETARY AND CONFIDENTIAL
156
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Address
Register
14E8H 14E9H14EEH 14EFH 14F0H14F6H 14F7H 14F8H14FEH 14FFH 1500H 1501H 1502H 1503H 1504H 1505H 1506H 1507H 1508H150EH 150FH 1510H1516H 1517H 1518H151EH 151FH
TRAP Remote Parallel Alarm Port TUG2 #1 of TUG3 #1 Configuration TRAP Remote Parallel Alarm Port TUG2 #2 to TUG2 #7 of TUG3 #1 Configuration TRAP Reserved TRAP Remote Parallel Alarm Port TUG2 #1 to TUG2 #7 of TUG3 #2 Configuration TRAP Reserved TRAP Remote Parallel Alarm Port TUG2 #1 to TUG2 #7 of TUG3 #3 Configuration TRAP Reserved TTOP TU #1 in TUG2 #1 of TUG3 #1, Control TTOP TU #1 in TUG2 #2 of TUG3 #1, Control TTOP TU #1 in TUG2 #3 of TUG3 #1, Control TTOP TU #1 in TUG2 #4 of TUG3 #1, Control TTOP TU #1 in TUG2 #5 of TUG3 #1, Control TTOP TU #1 in TUG2 #6 of TUG3 #1, Control TTOP TU #1 in TUG2 #7 of TUG3 #1, Control TTOP TU #1 in TUG2 #1 to TUG2 #7 of TUG3 #1BIP Diagnostic Control TTOP TU #2 in TUG2 #1 to TUG#7 of TUG3 #1, Control TTOP TU #2 in TUG2 #1 to TUG2 #7 of TUG3 #,1BIP Diagnostic Control TTOP TU #3 in TUG2 #1 to TUG#7 of TUG3 #1, Control TTOP TU #3 in TUG2 #1 to TUG2 #7 of TUG3 #1,BIP Diagnostic Control TTOP TU #4 in TUG2 #1 to TUG#7 of TUG3 #1, Control TTOP TU #4 in TUG2 #1 to TUG2 #7 of TUG3 #1, BIP Diagnostic Control
PROPRIETARY AND CONFIDENTIAL
157
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Address
Register
1520H153FH 1540H155FH 1560H 1561H 1562H 1563H 1564H 1565H 1566H 1567H 1568H157FH 1580H 1581H 1582H 1583H 1584H 1585H 1586H 1587H 1588H158EH 158FH 1590H1596H 1597H 1598H159EH
TTOP TUs #1 to 4 in TUG2s #1 to 7 of TUG3 #2, Control and BIP Diagnostic Control TTOP TUs #1 to 4 in TUG2s #1 to 7 of TUG3 #3, Control and BIP Diagnostic Control TTOP TUG3 #1Control TTOP TUG3 #2Control TTOP TUG3 #3Control Reserved TTOP Trail Trace Identifier Page Select TTOP Indirect Trail Trace Identifier Tributary Select TTOP Indirect Trail Trace Identifier Buffer Address TTOP Indirect Trail Trace Identifier Buffer Data Reserved TTMP TU #1 in TUG2 #1 of TUG3 #1, Tributary Control TTMP TU #1 in TUG2 #2 of TUG3 #1, Tributary Control TTMP TU #1 in TUG2 #3 of TUG3 #1, Tributary Control TTMP TU #1 in TUG2 #4 of TUG3 #1, Tributary Control TTMP TU #1 in TUG2 #5 of TUG3 #1, Tributary Control TTMP TU #1 in TUG2 #6 of TUG3 #1, Tributary Control TTMP TU #1 in TUG2 #7 of TUG3 #1, Tributary Control Reserved TTMP TU #2 in TUG2 #1 to TUG#7 of TUG3 #1, Tributary Control Reserved TTMP TU #3 in TUG2 #1 to TUG#7 of TUG3 #1, Tributary Control Reserved TTMP TU #4 in TUG2 #1 to TUG#7 of TUG3 #1, Tributary Control
PROPRIETARY AND CONFIDENTIAL
158
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Address
Register
159FH 15A0H15BFH 15C0H15DFH 15E0H 15E1H 15E2H 15E3H 15E4H 15E5H 15E6H 15E7H 15E8H 15E9H15F5H 15F6H15FFH 1600H163FH 1640H 1641H 1642H 1643H 1644H 1645H 1646H 1647H 1648H16FFH
Reserved TTMP TUs #1 to 4 in TUG2s #1 to 7 of TUG3 #2, Tributary Control TTMP TUs #1 to 4 in TUG2s #1 to 7 of TUG3 #3, Tributary Control TTMP Reserved TTMP Time Switch Page Control TTMP Indirect Time Switch RAM Control and Status TTMP Indirect Time Switch Tributary Address TTMP Indirect Time Switch Tributary Data TTMP Telecom Interface Configuration TTMP FIFO Depth TTMP MAP SVRam Capture Address TTMP MAP SVRam Control Signals and Bistinit Abort TTMP MAP SVRam Data Reserved Egress SIPO Reserved D3MD Control D3MD Interrupt Status D3MD Interrupt Enable Reserved D3MA Control D3MA Interrupt Status D3MA Interrupt Enable Reserved Reserved
PROPRIETARY AND CONFIDENTIAL
159
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Address 1700H179FH
Register SBI Interface
1700H 1701H 1702H 1703H170FH 1710H 1711H 1712H 1713H 1714H 1715H 1716H 1717H 1718H171DH 171EH 171FH 1720H 1721H 1722H 1723H 1724H 1725H 1726H 1727H172FH 1731H
SBI Master Reset / Bus Signal Monitor SBI Master Configuration SBI Bus Master Configuration SBI Reserved EXSBI Control EXSBI FIFO Underrun Interrupt Status EXSBI FIFO Overrun Interrupt Status EXSBI Tributary RAM Indirect Access Address EXSBI Tributary RAM Indirect Access Control EXSBI Reserved EXSBI Tributary Control Indirect Access Data EXSBI SBI Parity Error Interrupt Status EXSBI Reserved EXSBI Depth Check Interrupt Status EXSBI Extract External ReSynch Interrupt Status INSBI Control INSBI FIFO Underrun Interrupt Status INSBI FIFO Overrun Interrupt Status INSBI Tributary Register Indirect Access Address INSBI Tributary Register Indirect Access Control INSBI Reserved INSBI Tributary Control Indirect Access Data INSBI Reserved INSBI Depth Check Interrupt Status
PROPRIETARY AND CONFIDENTIAL
160
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Address
Register
1732H 1733H173FH 1740H175FH 1780H179FH 1780H1FFFH
INSBI Insert External ReSynch Interrupt Status INSBI Reserved SBI SIPO Reserved SBI PISO Reserved Reserved
For all register accesses, CSB must be low.
PROPRIETARY AND CONFIDENTIAL
161
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
10
NORMAL MODE REGISTER DESCRIPTION
Normal mode registers are used to configure and monitor the operation of the TEMUX. Normal mode registers (as opposed to test mode registers) are selected when TRS (A[13]) is low. Notes on Normal Mode Register Bits: 1) Writing values into unused register bits typically has no effect. However, to ensure software compatibility with future, feature-enhanced versions of the product, unused register bit must be written with logic 0. Reading back unused bits can produce either a logic 1 or a logic 0; hence unused register bits should be masked off by software when read. 2) All configuration bits that can be written into can also be read back. This allows the processor controlling the TEMUX to determine the programming state of the block. 3) Writeable normal mode register bits are cleared to logic 0 upon reset unless otherwise noted. 4) Writing into read-only normal mode register bit locations does not affect TEMUX operation unless otherwise noted. The register descriptions are contained in a separate TEMUX register description document.
PROPRIETARY AND CONFIDENTIAL
162
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
11
TEST FEATURES DESCRIPTION
The TEMUX contains test features for both production testing and board testing. Simultaneously asserting the CSB, RDB and WRB inputs causes all output pins and the data bus to be held in a high-impedance state. This test feature may be used for board testing. Test mode registers are used to apply test vectors during production testing of the TEMUX. Test mode registers (as opposed to normal mode registers) are selected when TRS (A[13]) is high.
Test Mode Register Memory Map Address Register
0000H1FFFH 2000H
2080H20FFH
Normal Mode Registers Master Test Register
T1/E1 Framer Slice #1
2090H2093H 2094H2097H 2098H209BH 209CH209FH 20A0H20A7H 20A8H20AFH 20B0H20B3H 20B4H20B7H
RJAT Test Registers TJAT Test Registers RX-ELST Test Registers TX-ELST Test Registers RXCE Test Registers TXCI Test Registers RPSC Test Registers TPSC Test Registers
PROPRIETARY AND CONFIDENTIAL
163
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
20B8H20BFH 20C0H20C7H 20C8H20CFH 20D0H20D7H 20D8H20DBH 20DCH20DFH 20E0H20E3H 20E4H20E5H 20E6H20E7H 20E8H20EBH 20ECH20EFH 20F0H20F7H 20E0H20EFH 20F0H20F7H 20F8H20FFH
2100H217FH 2180H21FFH
PMON Test Registers RDLC Test Registers TDPR Test Registersn PRBS Test Registers SIGX Test Registers RX-SIG-ELST Test Registers T1 ALMI Test Registers T1 XBOC Test Registers T1 RBOC Test Registers T1 XBAS Test Registers T1 FRMR Test Registers T1 APRM Test Registers E1 FRMR Test Registers E1 TRAN Test Registers Reserved
T1/E1 Framer Slice #2 T1/E1 Framer Slice #3
PROPRIETARY AND CONFIDENTIAL
164
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
2200H227FH 2280H22FFH 2300H237FH 2380H23FFH 2400H247FH 2480H24FFH 2500H257FH 2580H25FFH 2600H267FH 2680H26FFH 2700H277FH 2780H27FFH 2800H287FH 2880H28FFH 2900H297FH 2980H29FFH 2A00H2A7FH
T1/E1 Framer Slice #4 T1/E1 Framer Slice #5 T1/E1 Framer Slice #6 T1/E1 Framer Slice #7 T1/E1 Framer Slice #8 T1/E1 Framer Slice #9 T1/E1 Framer Slice #10 T1/E1 Framer Slice #11 T1/E1 Framer Slice #12 T1/E1 Framer Slice #13 T1/E1 Framer Slice #14 T1/E1 Framer Slice #15 T1/E1 Framer Slice #16 T1/E1 Framer Slice #17 T1/E1 Framer Slice #18 T1/E1 Framer Slice #19 T1/E1 Framer Slice #20
PROPRIETARY AND CONFIDENTIAL
165
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
2A80H2AFFH 2B00H2B7FH 2B80H2BFFH 2C00H2C7FH 2C80H2CFFH 2D00H2D7FH 2D80H2DFFH 2E00H2E7FH
T1/E1 Framer Slice #21 T1 Framer Slice #22 T1 Framer Slice #23 T1 Framer Slice #24 T1 Framer Slice #25 T1 Framer Slice #26 T1 Framer Slice #27 T1 Framer Slice #28
2E80H2FFFH
3000H30FFH
Reserved
DS3 FRAMER and M13 Multiplexer
3000H3007h 3008H300BH 300CH300FH 3010H301FH 3020H3027H 3028H3029H 3030H303FH
Reserved DS3 TRAN Test Registers DS3 FRMR Test Registers DS3 PMON Test Registers DS3 TDPR Test Registers DS3 RDLC Test Registers PRGD Test Registers
PROPRIETARY AND CONFIDENTIAL
166
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
3040H3047H 3048H304BH 304CH305FH 3060H3067H 3068H306FH 3070H3077H 3078H307FH 3080H3087H 3088H308FH 3090H3097H 3098H309FH 30A0H30A7H 30A8H30AFH 30B0H30B7H 30B8H30BFH 30C0H30C7H 30C8H30CFH
MX23 Test Registers FEAC XBOC Test Registers Reserved DS2 FRMR #1 Test Registers Reserved MX12 #1 Test Registers Reserved DS2 FRMR #2 Test Registers Reserved MX12 #2 Test Registers Reserved DS2 FRMR #3 Test Registers Reserved MX12 #3 Test Registers Reserved DS2 FRMR #4 Test Registers Reserved
PROPRIETARY AND CONFIDENTIAL
167
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
30D0H30D7H 30D8H30DFH 30E0H30E7H 30E8H30EFH 30F0H30F7H 30F8H30FFH 3100H3107H 3108H310FH 3110H3117H 3118H311FH 3120H3127H 3128H312FH 3130H3137H 3138H31FFH
3200H36FFH
MX12 #4 Test Registers Reserved DS2 FRMR #5 Test Registers Reserved MX12 #5 Test Registers Reserved DS2 FRMR #6 Test Registers Reserved MX12 #6 Test Registers Reserved DS2 FRMR #7 Test Registers Reserved MX12 #7 Test Registers Reserved
SONET/SDH Mapper and Demapper
3200H321F 3220H323FH
Reserved PISO Test Registers
PROPRIETARY AND CONFIDENTIAL
168
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
3240H327FH 3280H32FFH 3300H33FFH 3400H347FH 3480H34FFH 3500H357FH 3580H35FFH 3600H363FH 3640H3643H 3644H3647H 3648H36FFH
3700H379FH
Ingress VTPP Test Registers RTDM Test Registers RTOP Test Registers Egress VTPP Test Registers TRAP Test Registers TTOP Test Registers TTMP Test Registers SIPO Test Registers D3MD Test Registers D3MA Test Registers Reserved
SBI Interface
3700H370FH 3710H371FH 3720H373FH 3740H375FH 3780H379FH
Reserved EXSBI Test Registers INSBI Test Registers SBI SIPO Test Registers SBI PISO Test Registers
PROPRIETARY AND CONFIDENTIAL
169
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
3780H3FFFH
Reserved
Notes on Register Bits: 1) Writing values into unused register bits has no effect. Reading back unused bits can produce either a logic one or a logic zero; hence unused bits should be masked off by software when read. 2) Writeable register bits are not initialized upon reset unless otherwise noted.
PROPRIETARY AND CONFIDENTIAL
170
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Register 2000H: Master Test Register Bit Type Function Default
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 W W R/W W R/W
Unused Unused Unused PMCTST DBCTRL IOTST HIZDATA HIZIO
X X X X X X X X
This register is used to select TEMUX test features. All bits, except for PMCTST, are reset to zero by a hardware reset of the TEMUX; a software reset of the TEMUX does not affect the state of the bits in this register. PMCTST: The PMCTST bit is used to configure the TEMUX for PMC's manufacturing tests. When PMCTST is set to logic 1, the TEMUX microprocessor port becomes the test access port used to run the PMC "canned" manufacturing test vectors. The PMCTST bit is logically "ORed" with the IOTST bit, and can only be cleared by setting CSB to logic 1. DBCTRL: The DBCTRL bit is used to pass control of the data bus drivers to the CSB pin while IOTST is a logic 1. When the DBCTRL bit is set to logic 1, the CSB pin controls the output enable for the data bus. While the DBCTRL bit is set, holding the CSB pin high causes the TEMUX to drive the data bus and holding the CSB pin low tri-states the data bus. The DBCTRL bit overrides the HIZDATA bit. The DBCTRL bit is used to measure the drive capability of the data bus driver pads. When IOTST and PMCTST are both logic 0, the DBCTRL bit is ignored. IOTST: The IOTST bit is used to allow normal microprocessor access to the test registers and control the test mode in each TSB block in the TEMUX for board level testing. When IOTST is a logic 1, all blocks are held in test mode and the microprocessor may write to a block's test mode 0 registers to
PROPRIETARY AND CONFIDENTIAL
171
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
manipulate the outputs of the block and consequently the device outputs (refer to the "Test Mode 0 Details" in the "Test Features" section). HIZIO: The HIZIO bit controls the tri-state modes of the output pins of the TEMUX. While the HIZIO bit is a logic 1, all output pins of the TEMUX, except the data bus, are held in a high-impedance state. The microprocessor interface is still active. HIZDATA: The HIZDATA bit controls the tri-state modes of the TEMUX. While the HIZIO bit is a logic 1, all output pins of the TEMUX, except the data bus, are held in a high-impedance state. While the HIZDATA bit is a logic 1, the data bus is also held in a high-impedance state which inhibits microprocessor read cycles.
11.1 JTAG Test Port
The TEMUX JTAG Test Access Port (TAP) allows access to the TAP controller and the 4 TAP registers: instruction, bypass, device identification and boundary scan. Using the TAP, device input logic levels can be read, device outputs can be forced, the device can be identified and the device scan path can be bypassed. For more details on the JTAG port, please refer to the Operations section.
Table 11 - Instruction Register
Length - 3 bits
Instructions Selected Register Instruction Code IR[2:0]
EXTEST IDCODE SAMPLE BYPASS BYPASS STCTEST BYPASS BYPASS
Boundary Scan Identification Boundary Scan Bypass Bypass Boundary Scan Bypass Bypass
000 001 010 011 100 101 110 111
PROPRIETARY AND CONFIDENTIAL
172
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Table 12
- Identification Register
Length Version number Part Number Manufacturer's identification code Device identification
11.1.1 Boundary Scan Register
32 bits 5H 8315H 0CDH 583150CDH
The boundary scan register is made up of 286 boundary scan cells, divided into inout observation (IN_CELL), output (OUT_CELL) and bidirectional (IO_CELL) cells. These cells are detailed in the following pages. The first 32 cells form the ID code register and carry the code 083150CDH. The cells are arranged as follows:
Table 13 Pin/Enable - Boundary Scan Chain Register Bit Cell Type Device I.D.
HIZ ICLK[28] ICLK[27] ICLK[20] ICLK[19] IFP[19] ECLK[28]_OEN ECLK[28] ECLK[27]_OEN ECLK[27] ECLK[20]_OEN ECLK[20] ECLK[19]_OEN ECLK[19] ECLK[12]_OEN
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14
OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL
-
PROPRIETARY AND CONFIDENTIAL
173
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Pin/Enable
Register Bit
Cell Type
Device I.D.
ECLK[12] ECLK[11]_OEN ECLK[11] IFP[12] IFP[11] ICLK[12] ICLK[11] ID[12] ID[11] ID[26]_CASID[7] ID[25]_MVID[7] ICLK[26] ICLK[25] IFP[26] IFP[25] ECLK[26]_OEN ECLK[26] ECLK[25]_OEN ECLK[25] ED[26]_CASED[7] ED[25]_MVED[7] ED[18]_CASED[5] CTCLK CECLK_CMV8MCLK CEFP_CMVFPB CICLK_CMVFPC CIFP CCSED
15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42
IO_CELL OUT_CELL IO_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL
-
PROPRIETARY AND CONFIDENTIAL
174
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Pin/Enable
Register Bit
Cell Type
Device I.D.
ED[17]_MVED[5] CLK52M ED[10]_CASED[3] CCSID ECLK[18]_OEN ECLK[18] ECLK[17]_OEN ECLK[17] ECLK[10]_OEN ECLK[10] ED[9]_MVED[3] ICLK[18] ICLK[17] ID[18]_CASID[5] ID[17]_MVID[5] IFP[18] IFP[17] IFP[10] IFP[9] IFP[2] ID[10]_CASID[3] ID[9]_MVID[3] ICLK[10] ICLK[9] ECLK[9]_OEN ECLK[9] ECLK[2]_OEN ECLK[2]
43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70
IN_CELL IN_CELL IN_CELL OUT_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL IN_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL
-
PROPRIETARY AND CONFIDENTIAL
175
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Pin/Enable
Register Bit
Cell Type
Device I.D.
ICLK[2] ED[2]_CASED[1]_TFPI_TMFPI ECLK[1]_TGAPCLK_OEN ECLK[1]_TGAPCLK ED[1]_MVED[1]_TDATI ID[1]_MVID[1]_RDATO ID[2]_CASID[1]_ROVRHD ICLK[1]_RSCLK IFP[1]_RFPO_RMFPO TICLK RCLK RPOS_RDAT RNEG_RLCV TCLK TPOS_TDAT TNEG_TMFP LADATA[0]_OEN LADATA[0] LADATA[1]_OEN LADATA[1] LADATA[2]_OEN LADATA[2] LADATA[3]_OEN LADATA[3] LADATA[4]_OEN LADATA[4] LADATA[5]_OEN LADATA[5]
71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98
OUT_CELL IN_CELL OUT_CELL IO_CELL IN_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL IN_CELL IN_CELL IN_CELL IN_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL
-
PROPRIETARY AND CONFIDENTIAL
176
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Pin/Enable
Register Bit
Cell Type
Device I.D.
LADATA[6]_OEN LADATA[6] LADATA[7]_OEN LADATA[7] LADP_OEN LADP LAPL_OEN LAPL LAC1J1V1 LAOE LREFCLK LDAIS LAC1 LDTPL LDDATA[0] LDDATA[1] LDDATA[2] LDDATA[3] LDDATA[4] LDDATA[5] LDDATA[6] LDDATA[7] LDDP LDPL LDV5 LDC1J1V1 RADEAST RADEASTCLK
99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126
OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL
-
PROPRIETARY AND CONFIDENTIAL
177
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Pin/Enable
Register Bit
Cell Type
Device I.D.
RADEASTFP RADWEST RADWESTCLK RADWESTFP ICLK[3] ICLK[4] ID[3] ECLK[3]_OEN ECLK[3] ECLK[4]_OEN ECLK[4] ECLK[5]_OEN ECLK[5] IFP[3] IFP[4] IFP[5] IFP[6] IFP[13] IFP[14] ICLK[5] ICLK[6] ECLK[6]_OEN ECLK[6] ECLK[13]_OEN ECLK[13] ECLK[14]_OEN ECLK[14] ECLK[21]_OEN
127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154
IN_CELL IN_CELL IN_CELL IN_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL
-
PROPRIETARY AND CONFIDENTIAL
178
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Pin/Enable
Register Bit
Cell Type
Device I.D.
ECLK[21] ECLK[22]_OEN ECLK[22] ECLK[7]_OEN ECLK[7] ECLK[8]_OEN ECLK[8] IFP[21] IFP[22] ID[4] ID[5]_MVID[2] ID[6]_CASID[2] ID[13]_MVID[4] ID[14]_CASID[4] ED[3] ED[4] ED[5]_MVED[2] ED[6]_CASED[2] ED[13]_MVED[4] ED[14]_CASED[4] ID[21]_MVID[6] ID[22]_CASID[6] ICLK[13] ICLK[14] IFP[7] IFP[8] IFP[15] IFP[16]
155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182
IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL
-
PROPRIETARY AND CONFIDENTIAL
179
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Pin/Enable
Register Bit
Cell Type
Device I.D.
IFP[23] IFP[24] ICLK[21] ICLK[22] ICLK[7] ICLK[8] ID[7] ID[8] ICLK[15] ICLK[16] ICLK[23] ICLK[24] ED[22]_CASED[6] ED[21]_MVED[6] RECVCLK1 RECVCLK2 XCLK ECLK[15]_OEN ECLK[15] ECLK[16]_OEN ECLK[16] ECLK[23]_OEN ECLK[23] ECLK[24]_OEN ECLK[24] RSTB A[13] A[12]
183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210
OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL IN_CELL IN_CELL OUT_CELL OUT_CELL IN_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL IN_CELL IN_CELL IN_CELL
-
PROPRIETARY AND CONFIDENTIAL
180
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Pin/Enable
Register Bit
Cell Type
Device I.D.
A[11] A[10] A[9] A[8] A[7] A[6] A[5] A[4] A[3] A[2] A[1] A[0] RDB WRB ALE INTB CSB D[0]_OEN D[0] D[1]_OEN D[1] D[2]_OEN D[2] D[3]_OEN D[3] D[4]_OEN D[4] D[5]_OEN
211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238
IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL OUT_CELL IN_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL
-
PROPRIETARY AND CONFIDENTIAL
181
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Pin/Enable
Register Bit
Cell Type
Device I.D.
D[5] D[6]_OEN D[6] D[7]_OEN D[7] ID[15]_SDDATA[0]_OEN ID[15]_SDDATA[0] ID[16]_SDDATA[1]_OEN ID[16]_SDDATA[1] ID[19]_SDDATA[2]_OEN ID[19]_SDDATA[2] ID[20]_SDDATA[3]_OEN ID[20]_SDDATA[3] ID[23]_SDDATA[4]_OEN ID[23]_SDDATA[4] ID[24]_SDDATA[5]_OEN ID[24]_SDDATA[5] ID[27]_SDDATA[6]_OEN ID[27]_SDDATA[6] ID[28]_SDDATA[7]_OEN ID[28]_SDDATA[7] IFP[20]_SDDP_OEN IFP[20]_SDDP IFP[28]_SDV5_OEN IFP[28]_SDV5 IFP[27]_SDPL_OEN IFP[27]_SDPL SAJUST_REQ_OEN
239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266
IO_CELL OUT_CELL IO_CELL OUT_CELL IO_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL OUT_CELL
1 0 1 1 0 0 1 1 0 0 0 0 1
PROPRIETARY AND CONFIDENTIAL
182
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Pin/Enable
Register Bit
Cell Type
Device I.D.
SAJUST_REQ SBIACT_OEB SBIACT SBIDET[0] ED[7]_SBIDET[1] SREFCLK SC1FP_OEN SC1FP ED[15]_SADATA[0] ED[16]_SADATA[1] ED[19]_SADATA[2] ED[20]_SADATA[3] ED[23]_SADATA[4] ED[24]_SADATA[5] ED[27]_SADATA[6] ED[28]_SADATA[7] ED[8]_SADP ED[12]_SAPL ED[11]_SAV5 TDO TDI TCK TMS TRSTB
Notes:
267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285
OUT_CELL OUT_CELL OUT_CELL IN_CELL IN_CELL IN_CELL OUT_CELL IO_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL IN_CELL TAP Output TAP Input TAP Clock TAP Input TAP Input
0 1 0 1 0 0 0 1 1 0 0 0 0 0 1 1 0 1 0 -
1. Register bit 285 is the first bit of the scan chain (closest to TDI). 2. Enable cell pinname_OEN, tristates pin pinname when set high.
PROPRIETARY AND CONFIDENTIAL
183
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
3. Enable cell HIZ, tristates all pins that do not have an individual pinname_OEN enable signal.
PROPRIETARY AND CONFIDENTIAL
184
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
12
OPERATION
12.1 DS3 Frame Format
The TEMUX provides support for both the C-bit parity and M23 DS3 framing formats. The DS3 frame format is shown in Figure 13.
Figure 31
M-subframe 1 X 1 M-subframe 2 X 2 M-subframe 3 P 1 M-subframe 4 P 2 M-subframe 5 M1 M-subframe 6 M2 M-subframe 7 M3
- DS3 Frame Structure
84 bits F1 F1 F1 F1 F1 F1 F1 84 bits C1 C1 C1 C1 C1 C1 C1 84 bits F2 F2 F2 F2 F2 F2 F2 84 bits C2 C2 C2 C2 C2 C2 C2 84 bits F3 F3 F3 F3 F3 F3 F3 84 bits C3 C3 C3 C3 C3 C3 C3 84 bits F4 F4 F4 F4 F4 F4 F4 84 bits
Xx: X-Bit Channel *
*
Transmit: The TEMUX inserts the FERF signal on the X-bits. FERF generation is controlled by either the FERF bit of the DS3 TRAN Configuration register or by detection of OOF, RED, LOS and AIS, as configured by the TEMUX Master DS3 Alarm Enable register. Receive: The TEMUX monitors the state and detects changes in the state of the FERF signal on the X-bits.
Px: P-Bit Channel * *
Transmit: The TEMUX calculates the parity for the payload data over the previous M-frame and inserts it into the P1 and P2 bit positions. Receive: The TEMUX calculates the parity for the received payload. Errors are accumulated in the DS3 PMON Parity Error Event Count registers.
Mx: M-Frame Alignment Signal * *
Transmit: The TEMUX generates the M-frame alignment signal (M1 = 0, M2 = 1, M3 = 0). Receive: The TEMUX finds M-frame alignment by searching for the F-bits and the M-bits. Out-of-frame is removed if the M-bits are correct for three consecutive M-frames while no discrepancies have occurred in the F-bits. M-bit errors are counted in the DS3 PMON Framing Bit Error Event Count
PROPRIETARY AND CONFIDENTIAL
185
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
registers. When one or more M-bit errors are detected in 3 out of 4 consecutive M-frames, an out-of-frame defect is asserted (if MBDIS in the DS3 Framer Configuration register is a logic 0).
Fx: M-Subframe Alignment Signal * *
Transmit: The TEMUX generates the M-Subframe Alignment signal (F1=1, F2=0, F3=0, F4=1). Receive: The TEMUX finds M-frame alignment by searching for the F-bits and the M-bits. Out-of-frame is removed if the M-bits are correct for three consecutive M-frames while no discrepancies have occurred in the F-bits. F-bit errors are counted in the DS3 PMON Framing Bit Error Event Count registers. An out-of frame defect is asserted if 3 F-bit errors out of 8 or 16 consecutive F-bits are observed (as selected by the M3O8 bit in the DS3 FRMR Configuration register).
Cx: C-Bit Channels *
*
Transmit: When configured for M23 applications, the C-bits are forced to logic 1 with the exception of the C-bit Parity ID bit (the first C-bit of the first M-subframe), which is forced to toggle every M-frame. When configured for C-bit parity applications, the C-bit Parity ID bit is forced to logic 1. The second C-bit in M-subframe 1 is set to logic 1. The third C-bit in M-subframe 1 provides a far-end alarm and control (FEAC) signal. The FEAC channel is sourced by the DS3 XBOC block. The 3 Cbits in M-subframe 3 carry path parity information. The value of these 3 Cbits is the same as that of the P-bits. The 3 C-bits in M-subframe 4 are the FEBE bits. FEBE transmission is controlled by the DFEBE bit in the DS3 TRAN Diagnostic register and by the detection of receive framing bit and path parity errors. The 3 C-bits in M-subframe 5 contain the 28.2 kbit/s path maintenance datalink. These bits are inserted from the DS3 TDPR HDLC controller. The C-bits in M-subframes 2, 6, and 7 are unused and are set to logic 1. Receive: The CBITV register bit in the DS3 FRMR Status register is used to report the state of the C-bit parity ID bit, and hence whether a M23 or Cbit parity DS3 signal stream is being received. The FEAC channel on the third C-bit in M-subframe 1 is detected by the DS3 RBOC block. Path parity errors and detected FEBEs on the C-bits in M-subframes 3 and 4 are reported in the DS3 PMON Path Parity Error Event Count and FEBE Event Count registers respectively. The path maintenance datalink signal is extracted by theDS3 RDLC HDLC receiver (if enabled).
PROPRIETARY AND CONFIDENTIAL
186
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
12.2 Servicing Interrupts
The TEMUX will assert INTB to logic 0 when a condition which is configured to produce an interrupt occurs. To find which condition caused this interrupt to occur, the procedure outlined below should be followed: 1. Read the bits of the TEMUX Master Interrupt Source register (0020H) to identify which of the eight interrupt registers (0021H-0028H) needs to be read to identify the interrupt. For example, a logic one read in the DS3INT register bit indicates that an interrupt identified in the Master Interrupt Source DS3 register produced the interrupt. 2. Read the bits of the second level Master Interrupt Source register to identify the interrupt source. 3. Service the interrupt. 4. If the INTB pin is still logic 0, then there are still interrupts to be serviced. Otherwise, all interrupts have been serviced. Wait for the next assertion of INTB
12.3 Using the Performance Monitoring Features
The PMON blocks are provided for performance monitoring purposes. The DS3 PMON block is used to monitor DS3 performance primitives. The PMON blocks within each T1/E1 Framer slice are used to monitor T1 or E1 performance primitives. The counters in the DS3 PMON block has been sized as not to saturate if polled every second. The T1/E1 PMON event counters are of sufficient length so that the probability of counter saturation over a one second interval is very small (less than 0.001%). An accumulation interval is initiated by writing to one of the PMON event counter register addresses or by writing to the Master Revision/Global PMON Update register. After initiating an accumulation interval, 3.5 recovered clock periods (RCLK for the DS3 PMON) must be allowed to elapse to permit the PMON counter values to be properly transferred before the PMON registers may be read. The odds of any one of the T1/E1 counters saturating during a one second sampling interval go up as the bit error rate (BER) increases. At some point, the probability of counter saturation reaches 50%. This point varies, depending upon the framing format and the type of event being counted. The BER at which the probability of counter saturation reaches 50% is shown for various counters in Table 14 for E1 mode, and in Table 15 for T1 mode.
PROPRIETARY AND CONFIDENTIAL
187
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Table 14
- PMON Counter Saturation Limits (E1 mode) BER
Counter
FER CRCE FEBE
Table 15
4.0 X 10-3 cannot saturate cannot saturate
- PMON Counter Saturation Limits (T1 mode) Format BER
Counter
FER CRCE
SF ESF SF ESF
1.6 x 10-3 6.4 x 10-2 1.28 x 10-1 cannot saturate
Below these 50% points, the relationship between the BER and the counter event count (averaged over many one second samples) is essentially linear. Above the 50% point, the relationship between BER and the average counter event count is highly non-linear due to the likelihood of counter saturation. The following figures show this relationship for various counters and framing formats. These graphs can be used to determine the BER, given the average event count. In general, if the BER is above 10-3, the average counter event count cannot be used to determine the BER without considering the statistical effect of occasional counter saturation. Figure 32 illustrates the expected count values for a range of Bit Error Ratios in E1 mode.
PROPRIETARY AND CONFIDENTIAL
188
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Figure 32
9 Bit Error Rate (x 10 -3 ) 8 7 6 5 4 3 2 1 0
- FER Count vs. BER (E1 mode)
Average Count Over Many 1 Second Intervals
0
50
100
150
200
250
Framing Bit Error Count Per Second
Since the maximum number of CRC sub-multiframes that can occur in one second is 1000, the 10-bit FEBE and CRCE counters cannot saturate in one second. Despite this, there is not a linear relationship between BER and CRC-4 block errors due to the nature of the CRC-4 calculation. At BERs below 10-4, there tends to be no more than one bit error per sub-multiframe, so the number of CRC-4 errors is generally equal to the number of bit errors, which is directly related to the BER. However, at BERs above 10-4, each CRC-4 error is often due to more than one bit error. Thus, the relationship between BER and CRCE count becomes non-linear above a 10-4 BER. This must be taken into account when using CRC-4 counts to determine the BER. Since FEBEs are indications of CRCEs at the far end, and are accumulated identically to CRCEs, the same explanation holds for the FEBE event counter. The bit error rate for E1 can be calculated from the one-second PMON CRCE count by the following equation:
ae 8 ae oo c log c 1- CRCE / c e 8000 c 8*256 c c e
Bit Error Rate = 1 - 10
PROPRIETARY AND CONFIDENTIAL
189
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Figure 33
- CRCE Count vs. BER (E1 mode)
1.00E-02 1.00E-03 Bit Error Rate 1.00E-04 1.00E-05 1.00E-06 1.00E-07 0 200 400 600 CRCE 800 1000 1200
Figure 34 illustrates the expected count values for a range of Bit Error Ratios in T1 mode.
Figure 34
9
Bit Error Rate (x 10 -2 )
- FER Count vs. BER (T1 ESF mode)
Average Count Over Many 1 Second Intervals
8 7 6 5 4 3 2 1 0 0
50
100
150
200
250
Framing Bit Error Count Per Second
Since the maximum number of ESF superframes that can occur in one second is 333, the 9-bit BEE counter cannot saturate in one second in ESF framing format. Despite this, there is not a linear relationship between BER and BEE count, due to the nature of the CRC-6 calculation. At BERs below 10-4, there tends to be no more than one bit error per superframe, so the number of CRC-6 errors is generally equal to the number of bit errors, which is directly related to the BER.
PROPRIETARY AND CONFIDENTIAL
190
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
However, at BERs above 10-4, each CRC-6 error is often due to more than one bit error. Thus, the relationship between BER and BEE count becomes nonlinear above a 10-4 BER. This must be taken into account when using ESF CRC-6 counts to determine the BER. The bit error rate for T1 ESF can be calculated from the one-second PMON CRCE count by the following equation:
ae 24 ae oo c log c 1- BEE / c e 8000 c 24*193 c c e
Bit Error Rate = 1 - 10 Figure 35
- CRCE Count vs. BER (T1 ESF mode)
1.00E-02 1.00E-03 Bit Error Rate 1.00E-04 1.00E-05 1.00E-06 1.00E-07 0 50 100 150 200 250 300 350 CRCE
For T1 SF format, the CRCE and FER counts are identical, but the FER counter is smaller and should be ignored.
PROPRIETARY AND CONFIDENTIAL
191
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Figure 36
20
Bit Error Rate (x 10-2 )
- CRCE Count vs. BER (T1 SF mode)
Average Count Over Many 1 Second Intervals
18 16 14 12 10 8 6 4 2 0 0 200 400
600
800
1000
1200
Bit Error Event Count Per Second
12.4 Using the Internal FDL Transmitter
It is important to note that access rate to the TDPR registers is limited by the rate of the internal high-speed system clock which is either the DS3, DS1 or E1 clock. Consecutive accesses to the TDPR Configuration, TDPR Interrupt Status/UDR Clear, and TDPR Transmit Data register should be accessed (with respect to WRB rising edge and RDB falling edge) at a rate no faster than 1/8 that of the selected TDPR high-speed system clock. This time is used by the high-speed system clock to sample the event, write the FIFO, and update the FIFO status. Instantaneous variations in the high-speed reference clock frequencies (e.g. jitter in the line clock) must be considered when determining the procedure used to read and write the TDPR registers. Upon reset of the TEMUX, the TDPR should be disabled by setting the EN bit in the TDPR Configuration Register to logic 0 (default value). An HDLC all-ones Idle signal will be sent while in this state. The TDPR is enabled by setting the EN bit to logic 1. The FIFOCLR bit should be set and then cleared to initialize the TDPR FIFO. The TDPR is now ready to transmit. To initialize the TDPR, the TDPR Configuration Register must be properly set. If FCS generation is desired, the CRC bit should be set to logic 1. If the block is to be used in interrupt driven mode, then interrupts should be enabled by setting the FULLE, OVRE, UDRE, and LFILLE bits in the TDPR Interrupt Enable register to logic 1. The TDPR operating parameters in the TDPR Upper Transmit Threshold and TDPR Lower Interrupt Threshold registers should be set to the desired values. The TDPR Upper Transmit Threshold sets the value at which the TDPR automatically begins the transmission of HDLC packets, even if no complete packets are in the FIFO. Transmission will continue until the current
PROPRIETARY AND CONFIDENTIAL
192
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
packet is transmitted and the number of bytes in the TDPR FIFO falls to, or below, this threshold level. The TDPR will always transmit all complete HDLC packets (packets with EOM attached) in its FIFO. Finally, the TDPR can be enabled by setting the EN bit to logic 1. If no message is sent after the EN bit is set to logic 1, continuous flags will be sent. The TDPR can be used in a polled or interrupt driven mode for the transfer of data. In the polled mode the processor controlling the TDPR must periodically read the TDPR Interrupt Status register to determine when to write to the TDPR Transmit Data register. In the interrupt driven mode, the processor controlling the TDPR uses the INTB output, the one of the TEMUX Master Interrupt Source registers, and the TEMUX TDPR Interrupt Status registers to identify TDPR interrupts which determine when writes can or must be done to the TDPR Transmit Data register.
Interrupt Driven Mode:
The TDPR automatically transmits a packet once it is completely written into the TDPR FIFO. The TDPR also begins transmission of bytes once the FIFO level exceeds the programmable Upper Transmit Threshold. The CRC bit can be set to logic 1 so that the FCS is generated and inserted at the end of a packet. The TDPR Lower Interrupt Threshold should be set to such a value that sufficient warning of an underrun is given. The FULLE, LFILLE, OVRE, and UDRE bits are all set to logic 1 so an interrupt on INTB is generated upon detection of a FIFO full state, a FIFO depth below the lower limit threshold, a FIFO overrun, or a FIFO underrun. The following procedure should be followed to transmit HDLC packets: 1. Wait for a complete packet to be transmitted. Once data is available to be transmitted, then go to step 2. 2. Write the data byte to the TDPR Transmit Data register. 3. If all bytes of the packet have been written to the Transmit Data register, then set the EOM bit in the TDPR Configuration register to logic 1. Go to step 1. 4. If there are more bytes in the packet to be sent, then go to step 2. While performing steps 1 to 4, the processor should monitor for interrupts generated by the TDPR. When an interrupt is detected, the TDPR Interrupt Routine detailed in the following text should be followed immediately. The TDPR will force transmission of the packet information when the FIFO depth exceeds the threshold programmed with the UTHR[6:0] bits in the TDPR Upper Transmit Threshold register. Unless an error condition occurs, transmission will
PROPRIETARY AND CONFIDENTIAL
193
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
not stop until the last byte of all complete packets is transmitted and the FIFO depth is at or below the threshold limit. The user should watch the FULLI and LFILLI interrupts to prevent overruns and underruns.
TDPR Interrupt Routine:
Upon assertion of INTB, the source of the interrupt must first be identified by reading the TEMUX Master Interrupt Source register (0020H) followed by reading one of the second level master interrupt source registers T1E1INT1, T1E1INT2, T1E1INT3, T1E1INT4 or DS3INT. Once the source of the interrupt has been identified as the TDPR in use, then the following procedure should be carried out: 1. Read the TDPR Interrupt Status register. 2. If UDRI=1, then the FIFO has underrun and the last packet transmitted has been corrupted and needs to be retransmitted. When the UDRI bit transitions to logic 1, one Abort sequence and continuous flags will be transmitted. The TDPR FIFO is held in reset state. To re-enable the TDPR FIFO and to clear the underrun, the TDPR Interrupt Status/UDR Clear register should be written with any value. 3. If OVRI=1, then the FIFO has overflowed. The packet of which the last byte written into the FIFO belongs to, has been corrupted and must be retransmitted. Other packets in the FIFO are not affected. Either a timer can be used to determine when sufficient bytes are available in the FIFO or the user can wait until the LFILLI interrupt is set, indicating that the FIFO depth is at the lower threshold limit. If the FIFO overflows on the packet currently being transmitted (packet is greater than 128 bytes long), OVRI is set, an Abort signal is scheduled to be transmitted, the FIFO is emptied, and then flags are continuously sent until there is data to be transmitted. The FIFO is held in reset until a write to the TDPR Transmit Data register occurs. This write contains the first byte of the next packet to be transmitted. 4. If FULLI=1 and FULL=1, then the TDPR FIFO is full and no further bytes can be written. When in this state, either a timer can be used to determine when sufficient bytes are available in the FIFO or the user can wait until the LFILLI interrupt is set, indicating that the FIFO depth is at the lower threshold limit. If FULLI=1 and FULL=0, then the TDPR FIFO had reached the FULL state earlier, but has since emptied out some of its data bytes and now has space available in its FIFO for more data.
PROPRIETARY AND CONFIDENTIAL
194
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
5. If LFILLI=1 and BLFILL=1, then the TDPR FIFO depth is below its lower threshold limit. If there is more data to transmit, then it should be written to the TDPR Transmit Data register before an underrun occurs. If there is no more data to transmit, then an EOM should be set at the end of the last packet byte. Flags will then be transmitted once the last packet has been transmitted. If LFILLI=1 and BLFILL=0, then the TDPR FIFO had fallen below the lowerthreshold state earlier, but has since been refilled to a level above the lowerthreshold level.
Polling Mode:
The TDPR automatically transmits a packet once it is completely written into the TDPR FIFO. The TDPR also begins transmission of bytes once the FIFO level exceeds the programmable Upper Transmit Threshold. The CRC bit can be set to logic 1 so that the FCS is generated and inserted at the end of a packet. The TDPR Lower Interrupt Threshold should be set to such a value that sufficient warning of an underrun is given. The FULLE, LFILLE, OVRE, and UDRE bits are all set to logic 0 since packet transmission is set to work with a periodic polling procedure. The following procedure should be followed to transmit HDLC packets: 1. Wait until data is available to be transmitted, then go to step 2. 2. Read the TDPR Interrupt Status register. 3. If FULL=1, then the TDPR FIFO is full and no further bytes can be written. Continue polling the TDPR Interrupt Status register until either FULL=0 or BLFILL=1. Then, go to either step 4 or 5 depending on implementation preference. 4. If BLFILL=1, then the TDPR FIFO depth is below its lower threshold limit. Write the data into the TDPR Transmit Data register. Go to step 6. 5. If FULL=0, then the TDPR FIFO has room for at least 1 more byte to be written. Write the data into the TDPR Transmit Data register. Go to step 6. 6. If more data bytes are to be transmitted in the packet, then go to step 2. If all bytes in the packet have been sent, then set the EOM bit in the TDPR Configuration register to logic 1. Go to step 1.
PROPRIETARY AND CONFIDENTIAL
195
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
12.5 Using the Internal Data Link Receiver
It is important to note that the access rate to the RDLC registers is limited by the rate of the internal high-speed system clock which is either the DS3, DS1 or E1 system clock. Consecutive accesses to the RDLC Status and RDLC Data registers should be accessed at a rate no faster than 1/10 that of the selected RDLC high-speed system clock. This time is used by the high-speed system clock to sample the event and update the FIFO status. Instantaneous variations in the high-speed reference clock frequencies (e.g. jitter in the receive line clock) must be considered when determining the procedure used to read RDLC registers. On power up of the system, the RDLC should be disabled by setting the EN bit in the Configuration Register to logic 0 (default state). The RDLC Interrupt Control register should then be initialized to enable the INTB output and to select the FIFO buffer fill level at which an interrupt will be generated. If the INTE bit is not set to logic 1, the RDLC Status register must be continuously polled to check the interrupt status (INTR) bit. After the RDLC Interrupt Control register has been written, the RDLC can be enabled at any time by setting the EN bit in the RDLC Configuration register to logic 1. When the RDLC is enabled, it will assume the link status is idle (all ones) and immediately begin searching for flags. When the first flag is found, an interrupt will be generated, and a dummy byte will be written into the FIFO buffer. This is done to provide alignment of link up status with the data read from the FIFO. When an abort character is received, another dummy byte and link down status is written into the FIFO. This is done to provide alignment of link down status with the data read from the FIFO. It is up to the controlling processor to check the COLS bit in the RDLC Status register for a change in the link status. If the COLS bit is set to logic 1, the FIFO must be emptied to determine the current link status. The first flag and abort status encoded in the PBS bits is used to set and clear a Link Active software flag. When the last byte of a properly terminated packet is received, an interrupt is generated. While the RDLC Status register is being read the PKIN bit will be logic 1. This can be a signal to the external processor to empty the bytes remaining in the FIFO or to just increment a number-of-packets-received count and wait for the FIFO to fill to a programmable level. Once the RDLC Status register is read, the PKIN bit is cleared to logic 0 . If the RDLC Status register is read immediately after the last packet byte is read from the FIFO, the PBS[2] bit will be logic 1 and the CRC and non-integer byte status can be checked by reading the PBS[1:0] bits.
PROPRIETARY AND CONFIDENTIAL
196
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
When the FIFO fill level is exceeded, an interrupt is generated. The FIFO must be emptied to remove this source of interrupt. The RDLC can be used in a polled or interrupt driven mode for the transfer of frame data. In the polled mode, the processor controlling the RDLC must periodically read the RDLC Status register to determine when to read the RDLC Data register. In the interrupt driven mode, the processor controlling the RDLC uses the TEMUX INTB output and the TEMUX Master Interrupt Source registers to determine when to read the RDLC Data register. In the case of interrupt driven data transfer from the RDLC to the processor, the INTB output of the TEMUX is connected to the interrupt input of the processor. The processor interrupt service routine verifies what block generated the interrupt by reading the TEMUX Master Interrupt Source register followed by one of the second level master interrupt source registers to identify one of the 29 HDLC receivers as the interrupt source. Once it has identified that the RDLC has generated the interrupt, it processes the data in the following order: 1. Read the RDLC Status register. The INTR bit should be logic 1. 2. If OVR = 1, then discard the last frame and go to step 1. Overrun causes a reset of FIFO pointers. Any packets that may have been in the FIFO are lost. 3. If COLS = 1, then set the EMPTY FIFO software flag. 4. If PKIN = 1, increment the PACKET COUNT. If the FIFO is desired to be emptied as soon as a complete packet is received, set the EMPTY FIFO software flag. If the EMPTY FIFO software flag is not set, FIFO emptying will delayed until the FIFO fill level is exceeded. 5. Read the RDLC Data register. 6. Read the RDLC Status register. 7. If OVR = 1, then discard last frame and go to step 1. Overrun causes a reset of FIFO pointers. Any packets that may have been in the FIFO are lost. 8. If COLS = 1, then set the EMPTY FIFO software flag. 9. If PKIN = 1, increment the PACKET COUNT. If the FIFO is desired to be emptied as soon as a complete packet is received, set the EMPTY FIFO software flag. If the EMPTY FIFO software flag is not set, FIFO emptying will delayed until the FIFO fill level is exceeded. 10. Start the processing of FIFO data. Use the PBS[2:0] packet byte status bits to decide what is to be done with the FIFO data.
PROPRIETARY AND CONFIDENTIAL
197
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
If PBS[2:0] = 001, discard data byte read in step 5 and set the LINK ACTIVE software flag. If PBS[2:0] = 010, discard the data byte read in step 5 and clear the LINK ACTIVE software flag. If PBS[2:0] = 1XX, store the last byte of the packet, decrement the PACKET COUNT, and check the PBS[1:0] bits for CRC or NVB errors before deciding whether or not to keep the packet. If PBS[2:0] = 000, store the packet data. 11. If FE = 0 and INTR = 1 or FE = 0 and EMPTY FIFO = 1, go to step 5 else clear the EMPTY FIFO software flag and leave this interrupt service routine to wait for the next interrupt. The link state is typically a local software variable. The link state is inactive if the RDLC is receiving all ones or receiving bit-oriented codes which contain a sequence of eight ones. The link state is active if the RDLC is receiving flags or data. If the RDLC data transfer is operating in the polled mode, processor operation is exactly as shown above for the interrupt driven mode, except that the entry to the service routine is from a timer, rather than an interrupt.
PROPRIETARY AND CONFIDENTIAL
198
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Figure 37
- Typical Data Frame
BIT: 8
0
7
1
6
1
5
1
4
1
3
1
2
1
1
0
FLAG
Address (high) (low)
CONTROL
data bytes received and transferred to the FIFO Buffer
Frame Check Sequence 0 1 1 1 1 1 1 0
FLAG
Bit 1 is the first serial bit to be received. When enabled, the primary, secondary and universal addresses are compared with the high order packet address to determine a match.
Figure 38
DATA INT FE LA
- Example Multi-Packet Operational Sequence
FF F D D D D F D D D D D D D D DD A FF F F DD D D FF 1 2 3 45 6 7
F A D INT
- flag sequence (01111110) - abort sequence (01111111) - packet data bytes - active high interrupt output
PROPRIETARY AND CONFIDENTIAL
199
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
FE LA
- internal FIFO empty status - state of the LINK ACTIVE software flag
Figure 38 shows the timing of interrupts, the state of the FIFO, and the state of the Data Link relative the input data sequence. The cause of each interrupt and the processing required at each point is described in the following paragraphs. The actual interrupt signal, INTB, is active low and will be the inverse of the INT signal shown in figure 16. Also in this example, the programmable fill level set point is set at 8 bytes by writing this value into the INTC[6:0] bits of the RDLC Interrupt Control register. At points 1 and 5 the first flag after all ones or abort is detected. A dummy byte is written in the FIFO, FE goes low, and an interrupt goes active. When the interrupt is detected by the processor it reads the dummy byte, the FIFO becomes empty, and the interrupt is removed. The LINK ACTIVE (LA) software flag is set to logic 1. At points 2 and 6 the last byte of a packet is detected and interrupt goes high. When the interrupt is detected by the processor, it reads the data and status registers until the FIFO becomes empty. The interrupt is removed as soon as the RDLC Status register is read, since the FIFO fill level of 8 bytes has not been exceeded. It is possible to store many packets in the FIFO and empty the FIFO when the FIFO fill level is exceeded. In either case the processor should use this interrupt to count the number of packets written into the FIFO. The packet count or a software time-out can be used as a signal to empty the FIFO. At point 3 the FIFO fill level of 8 bytes is exceeded and interrupt goes high. When the interrupt is detected by the processor it must read the data and status registers until the FIFO becomes empty and the interrupt is removed. At points 4 or 7 an abort character is detected, a dummy byte is written into the FIFO, and interrupt goes high. When the interrupt is detected by the processor it must read the data and status registers until the FIFO becomes empty and the interrupt is removed. The LINK ACTIVE software flag is cleared.
12.6 T1 Automatic Performance Report Format Table 16 - Performance Report Message Structure and contents
Octet No. 1 2 3 4
Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 FLAG SAPI C/R EA TEI EA CONTROL
PROPRIETARY AND CONFIDENTIAL
200
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
5 6 7 8 9 10 11 12 13 14 15 Notes:
G3 FE G3 FE G3 FE G3 FE
LV SE LV SE LV SE LV SE
G4 LB G4 LB G4 LB G4 LB
U1 U2 G1 R U1 U2 G1 R U1 U2 G1 R U1 U2 G1 R FCS FCS FLAG
G5 G2 G5 G2 G5 G2 G5 G2
SL Nm SL Nm SL Nm SL Nm
G6 NI G6 NI G6 NI G6 NI
1. The order of transmission of the bits is LSB (Bit 1) to MSB (Bit 8).
Table 17 Octet No. - Performance Report Message Structure Notes Octet Contents Interpretation
1 2 3 4 5,6 7,8 9,10 11,12 13,14 15
01111110 00111000 00111010 00000001 00000011 Variable Variable Variable Variable Variable 01111110
Opening LAPD Flag From CI: TEI=0,EA=1 Unacknowledged Frame Data for latest second (T') Data for Previous Second(T'-1) Data for earlier Second(T'-2) Data for earlier Second(T'-3) CRC16 Frame Check Sequence Closing LAPD flag SAPI=14, C/R=0, EA=0 From carrier: SAPI=14,C/R=1,EA=0
PROPRIETARY AND CONFIDENTIAL
201
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Table 18 Bit Value
- Performance Report Message Contents Interpretation
G1=1 G2=1 G3=1 G4=1 G5=1 G6=1 SE=1 FE=1 LV=1 SL=1 LB=1 U1,U2=0 R=0 NmNI=00,01,10,11
CRC ERROR EVENT =1 112.7 Using the Per-Channel Serial Controllers 12.7.1 Initialization
Before the TPSC (RPSC) block can be used, a proper initialization of the internal registers must be performed to eliminate erroneous control data from being produced on the block outputs. The output control streams should be disabled by setting the PCCE bit in the TPSC (RPSC) Configuration Register to logic 0. Then, all 96 locations of the TPSC (RPSC) must be filled with valid data. Finally, the output streams can be enabled by setting the PCCE bit in the TPSC (RPSC) Configuration Register to logic 1.
PROPRIETARY AND CONFIDENTIAL
202
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
12.7.2 Direct Access Mode
Direct access mode to the TPSC or RPSC is not used in the TEMUX. However, direct access mode is selected by default whenever the TEMUX is reset. The IND bit within the TPSC and RPSC Configuration Registers must be set to logic 1 after a reset is applied.
12.7.3 Indirect Access Mode
Indirect access mode is selected by setting the IND bit in the TPSC or RPSC Configuration Register to logic 1. When using the indirect access mode, the status of the BUSY indication bit should be polled to determine the status of the microprocessor access: when the BUSY bit is logic 1, the TPSC or RPSC is processing an access request; when the BUSY bit is logic 0, the TPSC or RPSC has completed the request. The indirect write programming sequence for the TPSC (RPSC) is as follows: 1. Check that the BUSY bit in the TPSC (RPSC) P Access Status Register is logic 0. 2. Write the channel data to the TPSC (RPSC) Channel Indirect Data Buffer register. 3. Write RWB=0 and the channel address to the TPSC (RPSC) Channel Indirect Address/Control Register. 4. Poll the BUSY bit until it goes to logic 0. The BUSY bit will go to logic 1 immediately after step 3 and remain at logic 1 until the request is complete. 5. If there is more data to be written, go back to step 1. The indirect read programming sequence for the TPSC (RPSC) is as follows: 1. Check that the BUSY bit in the TPSC (RPSC) P Access Status Register is logic 0. 2. Write RWB=1 and the channel address to the TPSC (RPSC) Channel Indirect Address/Control Register. 3. Poll the BUSY bit, waiting until it goes to a logic 0. The BUSY bit will go to logic 1 immediately after step 2 and remain at logic 1 until the request is complete.
PROPRIETARY AND CONFIDENTIAL
203
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
4. Read the requested channel data from the TPSC (RPSC) Channel Indirect Data Buffer register. 5. If there is more data to be read, go back to step 1.
12.8 T1/E1 Framer Loopback Modes
The TEMUX provides three loopback modes for T1/E1 links to aid in network and system diagnostics. The internal T1/E1 line loopback can be initiated at any time via the P interface, but is usually initiated once an inband loopback activate code is detected. The system Diagnostic Digital loopback can be initiated at any time by the system via the P interface to check the path of system data through the framer. The payload can also be looped-back on a per-DS0 basis to allow network testing without taking an entire DS1 off-line.
T1/E1 Line Loopback
T1/E1 Line loopback is initiated by setting the LLOOP bit to a 1 in the T1/E1 Diagnostics register (000DH + N*80H, N=1 to 28). When in line loopback mode the appropriate T1/E1 framer in the TEMUX is configured to internally connect the jitter-attenuated clock and data from the RJAT to the transmit clock and data (shown as TxD[x] and TxCLK[x] in the lineloopback diagram) going to the M13 mux and SONET/SDH mapper. The RJAT may be bypassed if desired. Conceptually, the data flow through a single T1/E1 framer in this loopback condition is illustrated in Figure 39.
PROPRIETARY AND CONFIDENTIAL
204
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Figure 39
CTCLK*
- T1/E1 Line Loopback
TRANSMITTER
T1-XBAS/E1-TRAN BasicTransmitter: Frame Generation, Alarm Insertion, Signaling Trunk Conditioning I ti Line Coding TOPS Timing Options TJAT Digital Jitter Attenuator TxCLK[1:28] TxD[1:28]
ED[1:28] ECLK[1:28]/EFP[1:28]/ ESIG[1:28] CEFP* CECLK*
ESIF Egress Interface
CICLK* CIFP* ID[1:28] ICLK[1:28]/ISIG[1:28] IFP[1:28]
ELST Elastic Store ISIF Ingress Interface
FRAM Framer/ Slip Buffer RAM T1/E1-FRMR Framer: Frame Alignment, Alarm Extraction
Li ne L oopback
RxCLK[1:28] RxD[1:28]
RJAT Digital Jitter Attenuator
RECEIVER
T1/E1 Diagnostic Digital Loopback
When Diagnostic Digital loopback is initiated, by writing a 1 to the DLOOP bit in the T1/E1 Diagnostics register (000DH + N*80H, N=1 to 28), the appropriate T1/E1 framer in the TEMUX is configured to internally connect its transmit clock and data (shown as TxD[x] and TxCLK[x] in the diagnostic loopback figure) to the receive clock and data (shown as RxD[x] and RxCLK[x] in the diagnostic loopback figure) The data flow through a single T1/E1 framer in this loopback condition is illustrated in Figure 40.
PROPRIETARY AND CONFIDENTIAL
205
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Figure 40
CTCLK*
- T1/E1 Diagnostic Digital Loopback
TRANSMITTER
T1-XBAS/E1-TRAN BasicTransmitter: Frame Generation, Alarm Insertion, Signaling Trunk Conditioning I ti Line Coding TOPS Timing Options TJAT Digital Jitter Attenuator TxCLK[1:28] TxD[1:28]
ED[1:28] ECLK[1:28]/EFP[1:28]/ ESIG[1:28] CEFP* CECLK*
ESIF Egress Interface
Di agn ost i c Loopb ack
CICLK* CIFP* ID[1:28] ICLK[1:28]/ISIG[1:28] IFP[1:28] FRAM Framer/ Slip Buffer RAM T1/E1-FRMR Framer: Frame Alignment, Alarm Extraction RJAT Digital Jitter Attenuator RxCLK[1:28] RxD[1:28]
ELST Elastic Store ISIF Ingress Interface
RECEIVER
Per-Channel Loopback
The T1/E1 payload may be looped-back on a per-channel basis through the use of the TPSC. If all channels are looped-back, the result is very similar to Payload Loopback on other PMC framers. In order for per-channel loopback to operate correctly, the Ingress Interface must be in Clock Master mode. The LOOP bit must be set to logic 1 in the TPSC Internal Registers for each channel desired to be looped back, and the PCCE bit must be set to logic 1 in the TPSC Configuration register. When all these configurations have been made, the ingress DS0s or timeslots selected will overwrite their corresponding egress channels; the remaining egress channels will pass through intact. Note that because the egress and ingress streams will not be superframe aligned, that any robbed-bit signaling in the ingress stream may not fall in the correct frame once looped-back, and that egress robbed-bit signaling will overwrite the looped-back channel data if signaling insertion is enabled. PRBS generation and detection is not available in payload loopback mode. The data flow in per-channel loopback is illustrated in Figure 41.
PROPRIETARY AND CONFIDENTIAL
206
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Figure 41
CTCLK*
- Per-Channel Loopback
TRANSMITTER
T1-XBAS/E1-TRAN BasicTransmitter: Frame Generation, Alarm Insertion, Signaling Trunk Conditioning I ti Line Coding TOPS Timing Options TJAT Digital Jitter Attenuator TxCLK[1:28] TxD[1:28]
ED[1:28] ECLK[1:28]/EFP[1:28]/ ESIG[1:28] CEFP* CECLK*
ESIF Egress Interface TPSC Per-DS0 Serial Controller
MUX
Per - DS0 Loopback
FRAM Framer/ Slip Buffer RAM T1/E1-FRMR Framer: Frame Alignment, Alarm Extraction RJAT Digital Jitter Attenuator RxCLK[1:28] RxD[1:28]
ID[1:28] ICLK[1:28]/ISIG[1:28] IFP[1:28]
ELST Elastic Store ISIF Ingress Interface
RECEIVER
12.9 DS3 Loopback Modes
The TEMUX provides three DS3 M13 multiplexer loopback modes to aid in network and system diagnostics at the DS3 interface. The DS3 loopbacks can be initiated via the P interface whenever the DS3 framer/M13 multiplexer is enabled. The DS3 Master Data Source register controls the DS3 loopback modes. These loopbacks are also available when the DS3 mux is used with the DS3 mapper via the telecom bus interface.
DS3 Diagnostic Loopback
DS3 Diagnostic Loopback allows the transmitted DS3 stream to be looped back into the receive DS3 path, overriding the DS3 stream received on the RDAT/RPOS and RNEG/RLCV inputs. The RCLK signal is also substituted with the transmit DS3 clock, TCLK. While this mode is active, AIS may be substituted for the DS3 payload being transmitted on the TPOS/TDAT and TNEG/TMFP outputs. The configuration of the receive interface determines how the TNEG/TMFP signal is handled during loopback: if the UNI bit in the DS3 FRMR register is set, then the receive interface is configured for RDAT and RLCV, therefore the TNEG/TMFP signal is suppressed during loopback so that transmit
PROPRIETARY AND CONFIDENTIAL
207
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
MFP indications will not be seen nor accumulated as input LCVs. If the UNI bit is clear, then the interface is configured for bipolar signals RPOS and RNEG, therefore the TNEG is fed directly to the RNEG input. This diagnostic loopback can be used when configured as a multiplexer or as a framer only. The DS3 loopback mode is shown diagrammatically in Figure 42.
Figure 42
RCLK RPOS/ RDAT RNEG/ RLCV
- DS3 Diagnostic Loopback Diagram
F MX12 #7 F R MX12 #6 RM FR MX12 #5 M R F MR MX12 #4 RR F M MX12 #3 RR F M MX12 #2 R MX12 #1 FR RM MR R
DS3 FRMR
MX23
UNI TCLK TPOS/ TDAT TNEG/ TMFP Optional AIS Insertion
DS3 TRAN
DS3 Line Loopback
DS3 Line Loopbacks allow the received DS3 streams to be looped back into the transmit DS3 paths, overriding the DS3 streams created internally by the multiplexing of the lower speed tributaries. The transmit signals on TPOS/TDAT and TNEG/TMFP are substituted with the receive signals on RPOS/RDAT and RNEG/RLCV. The TCLK signal is also substituted with the receive DS3 clock, RCLK. While this mode is active, AIS may be substituted for the DS3 payload being transmitted on the TPOS/TDAT and TNEG/TMFP outputs. Note that the transmit interface must be configured to be the same as the DS3 FRMR receive interface for this mode to work properly. The DS3 line loopback mode is shown diagrammatically in Figure 43. There is a second form of line loopback which only loops back the DS3 payload. In this mode the DS3 framing overhead is regenerated for the received DS3 stream and then retransmitted. Line loopback is selected with the LLOOP bit in the DS3 Master Data source register and payload loopback is selected by the PLOOP bit in the same register.
PROPRIETARY AND CONFIDENTIAL
208
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Figure 43
RCLK RPOS/ RDAT RNEG/ RLCV
- DS3 Line Loopback Diagram
F MX12 #7 F R MX12 #6 RM FR MX12 #5 M R F MR MX12 #4 R F MR MX12 #3 RR F M MX12 #2 R MX12 #1 FR RM MR R
DS3 FRMR
MX23
TCLK TPOS/ TDAT TNEG/ TMFP
DS3 TRAN
DS2 Demultiplex Loopback
DS2 Demultiplex Loopbacks allow each of the seven demultiplexed DS2 streams to be looped back into the MX23 and multiplexed up into the transmit DS3 stream. This overrides the tributary DS2 streams coming from the MX12s. The DS2 loopback mode is shown diagrammatically in Figure 44 and is enabled via the MX23 Loopback Activate register.
Figure 44
RCLK RPOS/ RDAT RNEG/ RLCV
- DS2 Loopback Diagram
F MX12 #7 F R MX12 #6 RM FR MX12 #5 M R F MR MX12 #4 RR F M MX12 #3 RR F M MX12 #2 RR F MX12 #1 RM MR R
DS3 FRMR MX23
Optional DEMUX AIS Insertion
DS2 Tributary Loopback path TCLK TPOS/ TDAT TNEG/ TMFP
DS3 TRAN
PROPRIETARY AND CONFIDENTIAL
209
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
12.10 Telecom Bus Mapper/Demapper Loopback Modes
The TEMUX provides two loopbacks at the telecom bus interface to aid in network and system diagnostics at the SONET/SDH interface. These loopback modes can be enabled via the microprocessor whenever the SONET/SDH block is enabled as the mapper for the T1/E1 framer slices or as the mapper for the DS3 framer or M13 Multiplexer.
Telecom Diagnostic Loopback
The Telecom Bus Diagnostic Loopback allows the transmitted telecom bus stream to be looped back into the receive SONET/SDH receive path, overriding the data stream received on the telecom drop bus inputs. While Telecom diagnostic loopback is active, valid SONET/SDH data continues to be transmitted on the telecom add bus outputs. The entire telecom drop bus is overwritten by the diagnostic loopback even though only one STS-1 SPE, STM1/VC4 TUG3 or STM-1/VC3 is generated by the egress VTPP onto the telecom add bus. This loopback is only available for VT1.5/VT2/TU11/TU12 mapped tributaries. DS3 mapped tributaries must use the DS3 diagnostic loopback. The telecom bus diagnostic loopback mode is shown diagrammatically in Figure 45.
Figure 45 - Telecom Diagnostic Loopback Diagram
VTPP VT/TU Payload Processor RTDM Receive Tributary Demapper
LDDATA[7:0] LDDP LDPL LDC1J1
LADATA[7:0] LADP LAPL LAC1J1V1 LAC1
VTPP VT/TU Payload Processor
Telecom Line Loopback
The Telecom Bus Line Loopback allows the received telecom drop bus data to be looped back out the telecom add bus after being processed by both the ingress and egress VTPPs. Both VTPP must be setup for the same STS-1 SPE,
PROPRIETARY AND CONFIDENTIAL
210
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
STM-1/VC4 TUG3 or STM-1/VC3 otherwise no loopback data will get through. The ingress data path is not affected by the telecom line loopback. This loopback is only available for VT1.5/VT2/TU11/TU12 mapped tributaries. DS3 mapped tributaries must use the DS3 line loopback. The Telecom bus line loopback mode is shown diagrammatically in Figure 46.
Figure 46 - Telecom Line Loopback Diagram
VTPP VT/TU Payload Processor RTDM Receive Tributary Path O/H
LDDATA[7:0] LDDP LDPL LDC1J1
LADATA[7:0] LADP LAPL LAC1J1V1 LAC1
VTPP VT/TU Payload Processor
TTOP Transmit Tributary Path O/H
12.11 SBI Bus Data Formats
The TEMUX uses the Scaleable Bandwidth Interconnect (SBI) bus as a high density link interconnect with devices processing T1s, E1s, DS3s and transparent virtual tributaries. The SBI bus is a multi-point to multi-point bus capable of interconnecting up to three TEMUX devices in parallel with other link layer or tributary processing devices.
Multiplexing Structure
The SBI structure uses a locked SONET/SDH structure fixing the position of the TU-3 relative to the STS-3/STM-1. The SBI is also of fixed frequency and alignment as determined by the reference clock (SREFCLK) and frame indicator signal (SC1FP). Frequency deviations are compensated by adjusting the location of the T1/E1/DS3/TVT1.5/TVT2 channels using floating tributaries as determined by the V5 indicator and payload signals (SDV5, SAV5, SDPL and SAPL). TVTs also allow for synchronous operation where SONET/SDH tributary
PROPRIETARY AND CONFIDENTIAL
211
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
pointers are carried within the SBI structure in place of the V5 indicator and payload signals (SDV5, SAV5, SDPL and SAPL). Table 19 shows the bus structure for carrying T1, E1, TVT1.5, TVT2 and DS3 tributaries in a SDH STM-1 like format. Up to 84 T1s, 63 E1s, 84 TVT1.5s, 63 TVT2s or 3 DS3s are carried within the octets labeled SPE1, SPE2 and SPE3 in columns 16-270. All other octets are unused and are of fixed position. The frame signal (SC1FP) occurs during the octet labeled C1 in Row 1 column 7. The multiplexed links are separated into three Synchronous Payload Envelopes called SPE1, SPE2 and SPE3. Each envelope carries up to 28 T1s, 21 E1, 28 TVT1.5s, 21 TVT2s, or a DS3. SPE1 carries the T1s numbered 1,1 through 1,28, E1s numbered 1,1 through 1,21 or DS3 number 1,1. SPE2 carries T1s numbered 2,1 through 2,28, E1s numbered 2,1 through 2,21 or DS3 number 2,1. SPE3 carries T1s numbered 3,1 through 3,28, E1s numbered 3,1 through 3,21 or DS3 number 3,1. TVT1.5s are numbered the same as T1 tributaries and TVT2s are numbered the same as E1 tributaries. The most significant bit in all formats is the first bit of transmission.
PROPRIETARY AND CONFIDENTIAL
212
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Table 19
- Structure for Carrying Multiplexed Links
SBI Column 1 Row 1 2 6 7 8 15 16 17 18 19 268 269 270
- *** - C1 - *** - SPE1SPE2SPE3SPE1 *** SPE1SPE2SPE3 - *** - *** - SPE1SPE2SPE3SPE1 *** SPE1SPE2SPE3
* * *
9
1
2
3
3
- SPE1SPE2SPE3SPE1 5 6 6 6 7
SPE1SPE2SPE3 90 90 90
SPE Column
The TEMUX when enabled for SBI interconnection will add and drop either 28 T1s, 21 E1s or a DS3 into one of the three Synchronous Payload Envelopes, SPE1, SPE2 or SPE3. When T1 or E1 tributaries are sourced from the telecom bus via VT1.5, TU11, VT2 or TU12 mappings, the TEMUX also supports a mix of transparent virtual tributaries with T1s and E1s. Restriction to this are that only VT1.5s, TU11s and T1s can be mixed together or VT2s, TU12s and E1s can be mixed together. Another restriction is that the telecom bus and SBI bus must run from the same clock with a fixed framing offset, ie. SREFCLK and LREFCLK are externally connected.
Tributary Numbering
Tributary numbering for T1 and E1 uses the SPE number, followed by the Tributary number within that SPE and are numbered sequentially. Table 20 and Table 21 show the T1 and E1 column numbering and relates the tributary number to the SPE column numbers and overall SBI column structure. Numbering for DS3 follows the same naming convention even though there is only one DS3 per SPE. TVT1.5s and TVT2s follow the same numbering conventions as T1 and E1 tributaries respectively. SBI columns 16-18 are unused for T1, E1, TVT1.5 and TVT2 tributaries.
Table 20 T1#
1,1 2,1 3,1 1,2 2,2 8,36,64 8,36,64
- T1/TVT1.5 Tributary Column Numbering SPE1 Column SPE2 Column SPE3 Column
7,35,63 7,35,63 7,35,63
SBI Column
19,103,187 20,104,188 21,105,189 22,106,190 23,107,191
PROPRIETARY AND CONFIDENTIAL
213
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
***
1,28 2,28 3,28
34,62,90 34,62,90 34,62,90
100,184,268 101,185,269 102,186,270
Table 21 E1#
1,1 2,1 3,1 1,2 2,2
***
- E1/TVT2 Tributary Column Numbering SPE1 Column SPE2 Column SPE3 Column
7,28,49,70 7,28,49,70 7,28,49,70 8,29,50,71 8,29,50,71 27,48,69,90 27,48,69,90 27,48,69,90
SBI Column
19,82,145,208 20,83,146,209 21,84,147,210 22,85,148,211 23,86,149,212 79,142,205,268 80,143,206,269 81,144,207,270
1,21 2,21 3,21
SBI Timing Master Modes
The TEMUX supports both synchronous and asynchronous SBI timing modes. Synchronous modes apply only to T1 and E1 tributaries and are used with ingress elastic stores to rate adapt the receive tributaries to the fixed SBI data rate. Asynchronous modes allow T1, E1, DS3 and transparent tributaries to float within the SBI structure to accommodate differences in timing. Note that Synchronous mode SBI timing operation is required for support of Channel Associated Signaling (CAS). In synchronous SBI mode the T1 DS0s and E1 timeslots are in a fixed format and do not move relative to the SBI structure. The SBI frame pulse, SC1FP, in synchronous mode can be enabled to indicate CAS signaling multi-frame alignment by pulsing once every 12th 2KHz SC1FP frame pulse period. SREFCLK sets the ingress rate from the receive elastic store. In Asynchronous modes timing is communicated across the Scaleable Bandwidth Interconnect by floating data structures within the SBI. Payload indicator signals in the SBI control the position of the floating data structure and therefore the timing. When sources are running faster than the SBI the floating payload structure is advanced by an octet be passing an extra octet in the V3 octet locations (H3 octet for DS3 mappings). When the source is slower than the SBI bus, the floating payload is retarded by leaving the octet after the V3 or H3
PROPRIETARY AND CONFIDENTIAL
214
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
octet unused. Both these rate adjustments are indicated by the SBI control signals. Transparent VTs (TVTs) can float in the SBI structure in two ways. The first method uses valid V1 and V2 pointers to indicate positive and negative pointer justifications. The second methods uses the SBI signals SDV5, SAV5, SDPL and SAPL to indicate rate adjustments. In the DROP bus the TEMUX will always provide both valid pointers with valid SDV5 and SDPL signals. On the SBI Add Bus the TEMUX needs to be configured on a per tributary basis for either transparent VT mode. Transparent VT operation is configured on a per tributary basis via the ETVT and ETVTPTRDIS bits in the TTMP Tributary control registers. Note that the SC1FPEN bit in Register 1209H (SONET/SDH Master DS3 Clock Generation Control) must be set appropriately for TVT mode. On the DROP BUS the TEMUX is timing master as determined by the arrival rate of data over the SBI. On the ADD BUS the TEMUX can be either the timing master or the timing slave. When the TEMUX is the timing slave it receives its transmit timing information from the arrival rate of data across the SBI ADD bus. When the TEMUX is the timing master it signals devices on the SBI ADD bus to speed up or slow down with the justification request signal, SAJUST_REQ. The TEMUX as timing master indicates a speedup request to a Link Layer SBI device by asserting the justification request signal high during the V3 or H3 octet. When this is detected by the Link Layer it will speed up the channel by inserting extra data in the next V3 or H3 octet. The TEMUX indicates a slowdown request to the Link Layer by asserting the justification request signal high during the octet after the V3 or H3 octet. When detected by the Link Layer it will retard the channel by leaving the octet following the next V3 or H3 octet unused. Both advance and retard rate adjustments take place in the frame or multi-frame following the justification request.
SBI Link Rate Information
The TEMUX SBI bus provides a method for carrying link rate information between devices. This is optional on a per channel basis. Two methods are specified, one for T1 and E1 channels and the second for DS3 channels. Link rate information is not available for TVTs. These methods use the reference 19.44MHz SBI clock and the SC1FP frame synchronization signal to measure channel clock ticks and clock phase for transport across the bus. The T1 and E1 method allows for a count of the number of T1 or E1 rising clock edges between 2 KHz SC1FP frame pulses. This count is encoded in ClkRate[1:0] to indicate that the nominal number of clocks, one more than nominal or one less than nominal should be generated during the SC1FP period.
PROPRIETARY AND CONFIDENTIAL
215
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
This method also counts the number of 19.44MHz clock rising edges after sampling SC1FP high to the next rising edge of the T1 or E1 clock, giving the ability to control the phase of the generated clock. The link rate information passed across the SBI bus via the V4 octet and is shown in Table 22. Table 23 shows the encoding of the clock count, ClkRate[1:0], passed in the link rate octet.
PROPRIETARY AND CONFIDENTIAL
216
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Table 22
- SBI T1/E1 Link Rate Information *** *** ***
Clock Count Phase
SC1FP SREFCLK T1/E1 CLK
Link Rate Octet T1/E1 Format
Bit #
7 ALM
6 0
5:4 ClkRate[1:0]
3:0 Phase[3:0]
Table 23
- SBI T1/E1 Clock Rate Encoding T1 Clocks / 2KHz E1 Clocks / 2 KHz
ClkRate[1:0]
"00" - Nominal "01" - Fast "1x" - Slow
772 773 771
1024 1025 1023
The method for transferring DS3 link rate information across the SBI passes the encoded count of DS3 clocks between 2KHz SC1FP pulses in the same method used for T1/E1 tributaries, but does not pass any phase information. The other difference from T1/E1link rate is that ClkRate[1:0] indicates whether the nominal number of clocks are generated or if four fewer or four extra clocks are generated during the SC1FP period. The format of the DS3 link rate octet is shown in Table 24. This is passed across the SBI via the Linkrate octet which follows the H3 octet in the column, see Table 30. Table 25 shows the encoding of the clock count, ClkRate[1:0], passed in the link rate octet.
PROPRIETARY AND CONFIDENTIAL
217
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Table 24
- DS3 Link Rate Information
Link Rate Octet DS3 Format
Table 25
Bit #
7 0
6 0
5:4 ClkRate[1:0]
3:0 Unused
- DS3 Clock Rate Encoding DS3 Clocks / 2KHz
ClkRate[1:0]
"00" - Nominal "01" - Fast "1x" - Slow
SBI Alarms
22368 22372 22364
The TEMUX transfers alarm conditions across the SBI bus for T1 and E1 tributaries. The TEMUX does not support alarm conditions across the SBI bus for DS3 nor transparent VTs. Table 22 show the alarm indication bit, ALM, as bit 7 of the Link Rate Octet. Devices connecting to the TEMUX which do not support alarm indications must set this bit to 0 on the SBI ADD bus. The presence of an alarm condition is indicated by the ALM bit set high in the Link Rate Octet. The absence of an alarm condition is indicated by the ALM bit set low in the Link Rate Octet. In the egress direction the TEMUX can be configured to use the alarm bit to force AIS on a per link basis.
T1 Tributary Mapping
Table 26 shows the format for mapping 84 T1s within the SPE octets. The DS0s and framing bits within each T1 are easily located within this mapping for channelized T1 applications. It is acceptable for the framing bit to not carry a valid framing bit on the Add Bus since the physical layer device will provide this information. Unframed T1s use the exact same format for mapping 84 T1s into the SBI except that the T1 tributaries need not align with the frame bit and DS0 locations. The V1,V2 and V4 octets are not used to carry T1 data and are either reserved or used for control across the interface. When enabled, the V4 octet is the Link Rate octet of Tables 1 and 3. It carries alarm and clock phase information across the SBI bus. The V1 and V2 octets are unused and should be
PROPRIETARY AND CONFIDENTIAL
218
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
ignored by devices listening to the SBI bus. The V5 and R octets do not carry any information and are fixed to a zero value. The V3 octet carries a T1 data octet but only during rate adjustments as indicated by the V5 indicator signals, DV5 and AV5, and payload signals, SDPL and SAPL. The PPSSSSFR octets carry channel associated signaling (CAS) bits and the T1 framing overhead. The DS0 octets are the 24 DS0 channels making up the T1 link. The V1,V2,V3 and V4 octets are fixed to the locations shown. All the other octets, shown shaded for T1#1,1, float within the allocated columns maintaining the same order and moving a maximum of one octet per 2KHz multi-frame. The position of the floating T1 is identified via the V5 Indicator signals, SDV5 and SAV5, which locate the V5 octet. When the T1 tributary rate is faster than the SBI nominal T1 tributary rate, the T1 tributary is shifted ahead by one octet which is compensated by sending an extra octet in the V3 location. When the T1 tributary rate is slower than the nominal SBI tributary rate the T1 tributary is shifted by one octet which is compensated by inserting a stuff octet in the octet immediately following the V3 octet and delaying the octet that was originally in that position.
Table 26
ROW # 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9
- T1 Framing Format
COL # 1-18 Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused T1#1,1 19 V1 DS0#1 DS0#4 DS0#7 DS0#10 DS0#13 DS0#16 DS0#19 DS0#22 V2 DS0#1 DS0#4 DS0#7 DS0#10 DS0#13 DS0#16 DS0#19 DS0#22 T1#2,1-3,28 20-102 V1 V2 T1#1,1 103 V5 DS0#2 DS0#5 DS0#8 DS0#11 DS0#14 DS0#17 DS0#20 DS0#23 R DS0#2 DS0#5 DS0#8 DS0#11 DS0#14 DS0#17 DS0#20 DS0#23 T1#2,1-3,28 104-186 T1#1,1 187 PPSSSSFR DS0#3 DS0#6 DS0#9 DS0#12 DS0#15 DS0#18 DS0#21 DS0#24 PPSSSSFR DS0#3 DS0#6 DS0#9 DS0#12 DS0#15 DS0#18 DS0#21 DS0#24 T1#2,1-3,28 188-270 -
PROPRIETARY AND CONFIDENTIAL
219
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
COL # ROW # 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 1-18 Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused
T1#1,1 19 V3 DS0#1 DS0#4 DS0#7 DS0#10 DS0#13 DS0#16 DS0#19 DS0#22 V4 DS0#1 DS0#4 DS0#7 DS0#10 DS0#13 DS0#16 DS0#19 DS0#22
T1#2,1-3,28 20-102 V3 V4 -
T1#1,1 103 R DS0#2 DS0#5 DS0#8 DS0#11 DS0#14 DS0#17 DS0#20 DS0#23 R DS0#2 DS0#5 DS0#8 DS0#11 DS0#14 DS0#17 DS0#20 DS0#23
T1#2,1-3,28 104-186 -
T1#1,1 187 PPSSSSFR DS0#3 DS0#6 DS0#9 DS0#12 DS0#15 DS0#18 DS0#21 DS0#24 PPSSSSFR DS0#3 DS0#6 DS0#9 DS0#12 DS0#15 DS0#18 DS0#21 DS0#24
T1#2,1-3,28 188-270 -
The P1P0S1S2S3S4FR octet carries T1 framing in the F bit and channel associated signaling in the P1P0and S1S2S3S4bits. Channel associated signaling is optional. The R bit is reserved and is set to 0. The P1P0bits are used to indicate the phase of the channel associated signaling and the S1S2S3S4 bits are the channel associated signaling bits for the 24 DS0 channels in the T1. Table 27 shows the channel associated signaling bit mapping and how the phase bits locate the sixteen state CAS mapping as well as T1 frame alignment for super frame and extended superframe formats. When using four state CAS then the signaling bits are A1-A24, B1-B24, A1-B24, B1-B24 in place of are A1-A24, B1B24, C1-C24, D1-D24. When using 2 state CAS there are only A1-A24 signaling bits.
PROPRIETARY AND CONFIDENTIAL
220
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Table 27
S1 A1 A5 A9 A13 A17 A21 B1 B5 B9 B13 B17 B21 C1 C5 C9 C13 C17 C21 D1 D5 D9 D13 D17 D21 S2 A2 A6 A10 A14 A18 A22 B2 B6 B10 B14 B18 B22 C2 C6 C10 C14 C18 C22 D2 D6 D10 D14 D18 D22
- T1 Channel Associated Signaling bits
SF S3 A3 A7 A11 A15 A19 A23 B3 B7 B11 B15 B19 B23 C3 C7 C11 C15 C19 C23 D3 D7 D11 D15 D19 D23 S4 A4 A8 A12 A16 A20 A24 B4 B8 B12 B16 B20 B24 C4 C8 C12 C16 C20 C24 D4 D8 D12 D16 D20 D24 F F1 S1 F2 S2 F3 S3 F4 S4 F5 S5 F6 S6 F1 S1 F2 S2 F3 S3 F4 S4 F5 S5 F6 S6 ESF F M1 C1 M2 F1 M3 C2 M4 F2 M5 C3 M6 F3 M7 C4 M8 F4 M9 C5 M10 F5 M11 C6 M12 F6 P1 P0 00 00 00 00 00 00 01 01 01 01 01 01 10 10 10 10 10 10 11 11 11 11 11 11
Note that in synchronous mode, the SF/ESF F-bits may have arbitrary alignment with respect to the P1P0 phase alignment bits, due to possible frame slips at the T1 level. However, CAS is always aligned to the P1P0 bits (i.e. in either synchronous or asynchronous mode). T1 tributary asynchronous timing is compensated via the V3 octet. T1 tributary link rate adjustments are optionally passed across the SBI via the V4. T1 tributary alarm conditions are optionally passed across the SBI bus via the link rate octet in the V4 location. In synchronous mode the T1 tributary mapping is fixed to that shown in Table 26 and rate justifications are not possible using the V3 octet. The clock rate information within the link rate octet in the V4 location is not used in synchronous mode.
PROPRIETARY AND CONFIDENTIAL
221
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
E1 Tributary Mapping
Table 28 shows the format for mapping 63 E1s within the SPE octets. The timeslots and framing bits within each E1 are easily located within this mapping for channelized E1 applications. It is acceptable for the framing bits to not carry valid framing information on the Add Bus since the physical layer device will provide this information. Unframed E1s use the exact same format for mapping 63 E1s into the SBI except that the E1 tributaries need not align with the timeslot locations associated with channelized E1 applications. The V1,V2 and V4 octets are not used to carry E1 data and are either reserved used for control information across the interface. When enabled, the V4 octet carries clock phase information across the SBI. The V1 and V2 octets are unused and should be ignored by devices listening to the SBI bus. The V5 and R octets do not carry any information and are fixed to a zero value. The V3 octet carries an E1 data octet but only during rate adjustments as indicated by the V5 indicator signals, SDV5 and SAV5, and payload signals, SDPL and SAPL. The PP octets carry channel associated signaling phase information and E1 frame alignment. TS#0 through TS#31 make up the E1 channel. The V1,V2,V3 and V4 octets are fixed to the locations shown. All the other octets, shown shaded for E1#1,1, float within the allocated columns maintaining the same order and moving a maximum of one octet per 2KHz multi-frame. The position of the floating E1 is identified via the V5 Indicator signals, SDV5 and SAV5, which locate the V5 octet. When the E1 tributary rate is faster than the E1 tributary nominal rate, the E1 tributary is shifted ahead by one octet which is compensated by sending an extra octet in the V3 location. When the E1 tributary rate is slower than the nominal rate the E1 tributary is shifted by one octet which is compensated by inserting a stuff octet in the octet immediately following the V3 octet and delaying the octet that was originally in that position.
Table 28
COL # ROW # 1 2 3 4 5 6 7 8 9 1-18 Unused Unused Unused Unused Unused Unused Unused Unused Unused
- E1 Framing Format
E1#1,1 #2,1-3,21 E1#1,1 #2,1-3,21 E1#1,1 #2,1-3,21 E1#1,1 #2,1-3,21 19 V1 TS#1 TS#5 TS#9 TS#13 TS#17 TS#21 TS#25 TS#29 20-81 V1 82 V5 TS#2 TS#6 TS#10 TS#14 TS#18 TS#22 TS#26 TS#30 83-144 145 PP TS#3 TS#7 TS#11 TS#15 TS#19 TS#23 TS#27 TS#31 146-207 208 TS#0 TS#4 TS#8 TS#12 TS#16 TS#20 TS#24 TS#28 R 209-270 -
PROPRIETARY AND CONFIDENTIAL
222
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9
Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused
V2 TS#1 TS#5 TS#9 TS#13 TS#17 TS#21 TS#25 TS#29 V3 TS#1 TS#5 TS#9 TS#13 TS#17 TS#21 TS#25 TS#29 V4 TS#1 TS#5 TS#9 TS#13 TS#17 TS#21 TS#25 TS#29
V2 V3 V4 -
R TS#2 TS#6 TS#10 TS#14 TS#18 TS#22 TS#26 TS#30 R TS#2 TS#6 TS#10 TS#14 TS#18 TS#22 TS#26 TS#30 R TS#2 TS#6 TS#10 TS#14 TS#18 TS#22 TS#26 TS#30
-
PP TS#3 TS#7 TS#11 TS#15 TS#19 TS#23 TS#27 TS#31 PP TS#3 TS#7 TS#11 TS#15 TS#19 TS#23 TS#27 TS#31 PP TS#3 TS#7 TS#11 TS#15 TS#19 TS#23 TS#27 TS#31
-
TS#0 TS#4 TS#8 TS#12 TS#16 TS#20 TS#24 TS#28 R TS#0 TS#4 TS#8 TS#12 TS#16 TS#20 TS#24 TS#28 R TS#0 TS#4 TS#8 TS#12 TS#16 TS#20 TS#24 TS#28 R
-
When using channel associated signaling (CAS) TS#16 carries the ABCD signaling bits and the timeslots 17 through 31 are renumbered 16 through 30. The PP octet is 0h for all frames except for the frame which carries the CAS for timeslots 15/30 at which time the PP octet is C0h. The first octet of the CAS multi-frame, RRRRRRRR, is reserved and should be ignored by the receiver when CAS signaling is enabled. Table 29 shows the format of timeslot 16 when carrying channel associated signaling.
PROPRIETARY AND CONFIDENTIAL
223
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Table 29
TS#16[7:4] RRRR ABCD1 ABCD2 ABCD3 ABCD4 ABCD5 ABCD6 ABCD7 ABCD8 ABCD9 ABCD10 ABCD11 ABCD12 ABCD13 ABCD14 ABCD15
- E1 Channel Associated Signaling bits
TS#16[3:0] RRRR ABCD16 ABCD17 ABCD18 ABCD19 ABCD20 ABCD21 ABCD22 ABCD23 ABCD24 ABCD25 ABCD26 ABCD27 ABCD28 ABCD29 ABCD30 PP 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 C0
E1 tributary asynchronous timing is compensated via the V3 octet. E1 tributary link rate adjustments are optionally passed across the SBI via the V4 octet. E1 tributary alarm conditions are optionally passed across the SBI bus via the link rate octet in the V4 location. In synchronous mode the E1 tributary mapping is fixed to that shown in Table 28 and rate justifications are not possible using the V3 octet. The clock rate information within the link rate octet in the V4 location is not used in synchronous mode. Note that ITU-T G.747 mutiplexed E1 streams are not supported over the SBI interface. This E1 mode of operation is restricted to using the serial clock and data or H-MVIP system interfaces.
DS3 Tributary Mapping
Table 30 shows a DS3 tributary mapped within the first synchronous payload envelope SPE1. The V5 indicator pulse identifies the V5 octet. The DS3 framing format does not follow an 8KHz frame period so the floating DS3 multi-frame located by the V5 indicator, shown in heavy border grey region in Table 30, will jump around relative to the H1 frame on every pass. In fact the V5 indicator will often be asserted twice per H1 frame, as is shown by the second V5 octet in Table 30. The V5 indicator and payload signals indicate negative and positive
PROPRIETARY AND CONFIDENTIAL
224
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
rate adjustments which are carried out by either putting a data byte in the H3 octet or leaving empty the octet after the H3 octet.
Table 30
SPE COL # SBI COL# ROW 1 2 3 4 5 6 7 8 9 1,4,7,10 Unused Unused Unused Unused Unused Unused Unused Unused 13 H1 H2 H3 Unused Unused Unused Unused Unused 16 V5 DS3 DS3 DS3 DS3 DS3 DS3 DS3 DS3 *** DS3 DS3 DS3 DS3 DS3 DS3 DS3 DS3 DS3 184 DS3 DS3 DS3 DS3 DS3 DS3 DS3 V5 DS3 *** DS3 DS3 DS3 DS3 DS3 DS3 DS3 DS3 DS3 268 DS3 DS3 DS3 DS3 DS3 DS3 DS3 DS3 DS3
- DS3 Framing Format
DS3 1 DS3 2-56 DS3 57 DS3 58-84 DS3 Col 85
Unused Linkrate
Because the DS3 tributary rate is less than the rate of the grey region, padding octets are interleaved with the DS3 tributary to make up the difference in rate. Interleaved with every DS3 multi-frame are 35 stuff octets, one of which is the V5 octet. These 35 stuff octets are spread evenly across seven DS3 subframes. Each DS3 subframe is eight blocks of 85 bits. The 85 bits making up a DS3 block are padded out to be 11 octets. Table 31 shows the DS3 block 11 octet format where R indicates a stuff bit, F indicates a DS3 framing bit and I indicates DS3 information bits. Table 32 shows the DS3 multi-frame format that is packed into the grey region of Table 30. In this table V5 indicates the V5 octet which is also a stuff octet, R indicates a stuff octet and B indicates the 11 octet DS3 block. Each row in Table 32 is a DS3 multi-frame. The DS3 multi-frame stuffing format is identical for 5 multi-frames and then an extra stuff octet after the V5 octet is added every sixth frame.
Table 31
Octet # Data
- DS3 Block Format
1 RRRFIIII 2 8*I 3 8*I 4 8*I 5 8*I 6 8*I 7 8*I 8 8*I 9 8*I 10 8*I 11 8*I
PROPRIETARY AND CONFIDENTIAL
225
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Table 32
V5 V5 V5 V5 V5 V5 4*R 4*R 4*R 4*R 4*R 5*R
- DS3 Multi-frame Stuffing Format
8*B 8*B 8*B 8*B 8*B 8*B 5*R 5*R 5*R 5*R 5*R 5*R 8*B 8*B 8*B 8*B 8*B 8*B 5*R 5*R 5*R 5*R 5*R 5*R 8*B 8*B 8*B 8*B 8*B 8*B 5*R 5*R 5*R 5*R 5*R 5*R 8*B 8*B 8*B 8*B 8*B 8*B 5*R 5*R 5*R 5*R 5*R 5*R 8*B 8*B 8*B 8*B 8*B 8*B 5*R 5*R 5*R 5*R 5*R 5*R 8*B 8*B 8*B 8*B 8*B 8*B 5*R 5*R 5*R 5*R 5*R 5*R 8*B 8*B 8*B 8*B 8*B 8*B
DS3 asynchronous timing is compensated via the H3 octet. DS3 link rate adjustments are optionally passed across the SBI via the Linkrate octet.
Transparent VT1.5/TU11 Mapping
VT1.5 and TU11 virtual tributaries, TVT1.5s, are transported across the SBI bus in a similar manner to the T1 tributary mapping. Table 33 shows the transparent structure where "I" is used to indicate information bytes. There are two options when carrying virtual tributaries on the SBI bus, the primary difference being how the floating V5 payload is located. The first option is locked TVT mode which carries the entire VT1.5/TU11 virtual tributary indicated by the shaded region in Table 33. Locked is used to indicate that the location of the V1,V2 pointer is locked. The virtual tributary must have a valid V1,V2 pointer to locate the V5 payload. In this mode the V5 indicator and payload signals, SDV5, SAV5, SDPL and SAPL, may be generated but must be ignored by the receiving device. In locked mode timing is always sourced by the transmitting side, therefore justification requests are not used and the SAJUST_REQ signal is ignored. Other than the V1 and V2 octets which must carry valid pointers, all octets can carry data in any format. The location of the V1,V2,V3 and V4 octets is fixed to the locations shown in Table 33. The second option is floating TVT mode which carries the payload comprising the V5 and I octets within the shaded region of Table 33. In this mode the V1,V2 pointers are still in a fixed location and may be valid but are ignored by the receiving device. The V5 indicator and payload signals, SDV5, SAV5, SDPL and SAPL, must be valid and are used to locate the floating payload. (i.e. SDV5/SAV5 are high during the V5 octet, and SDPL/SAPL are high during all shaded bytes except the V1/V2/V4 octets and the V3 octet or the octet after V3 depending on pointer movements.) The justification request signal can be used to control the timing on the add bus. The location of the V1,V2,V3 and V4 octets is fixed to the locations shown in Table 33.
PROPRIETARY AND CONFIDENTIAL
226
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
The TEMUX supports both TVT modes simultaneously in the SBI DROP bus and is configurable on a per tributary basis in the SBI ADD bus.
Table 33
ROW # 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7
- Transparent VT1.5/TU11 Format
COL # 1-18 Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused VT1.5#1,1 19 V1 I I I I I I I I V2 I I I I I I I I V3 I I I I I I I I V4 I I I I I I #2,1-3,28 20-102 V1 V2 V3 V4 VT1.5#1,1 103 V5 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I #2,1-3,28 104-186 VT1.5#1,1 187 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I #2,1-3,28 188-270 -
PROPRIETARY AND CONFIDENTIAL
227
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
8 9
Unused Unused
I I
-
I I
-
I I
-
Transparent VT2/TU12 Mapping
VT2 and TU12 virtual tributaries, TVT2s, are transported across the SBI bus in a similar manner to the E1 tributary mapping. The TEMUX supports both TVT modes simultaneously in the SBI DROP bus and is configurable on a per tributary basis in the SBI ADD bus. Table 34 shows the transparent structure where "I" is used to indicate information bytes. There are two options when carrying virtual tributaries on the SBI bus, the primary difference being how the floating V5 payload is located. The first option is locked TVT mode which carries the entire VT2/TU12 virtual tributary indicated by the shaded region in Table 34. The TEMUX supports both TVT modes simultaneously in the SBI DROP bus and is configurable on a per tributary basis in the SBI ADD bus. Locked is used to indicate that the location of the V1,V2 pointer is locked. The virtual tributary must have a valid V1,V2 pointer to locate the V5 payload. In this mode the V5 indicator and payload signals, SDV5, SAV5, SDPL and SAPL, are optionally generated but must be ignored by the receiving device. In locked mode timing is always sourced by the transmitting side, therefore justification requests are not used and the SAJUST_REQ signal is ignored. Other than the V1 and V2 octets which are carrying valid pointers, all octets can carry data in any format. The location of the V1,V2,V3 and V4 octets is fixed to the locations shown in Table 34. The second option is floating TVT mode which carries the payload comprised of the V5 and I octets within the shaded region of The TEMUX supports both TVT modes simultaneously in the SBI DROP bus and is configurable on a per tributary basis in the SBI ADD bus. Table 34. The TEMUX supports both TVT modes simultaneously in the SBI DROP bus and is configurable on a per tributary basis in the SBI ADD bus. In this mode the V1,V2 pointers are still in a fixed location and may be valid but are ignored by the receiving device. The V5 indicator and payload signals, SDV5, SAV5, SDPL and SAPL, must be valid and are used to locate the floating payload. (i.e. SDV5/SAV5 are high during the V5 octet, and SDPL/SAPL are high during all shaded bytes except the V1/V2/V4 octets and the V3 octet or the octet after V3 depending on pointer movements.) The justification request signal can
PROPRIETARY AND CONFIDENTIAL
228
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
be used to control the timing on the add bus. The location of the V1,V2,V3 and V4 octets is fixed to the locations shown in Table 34. The TEMUX supports both TVT modes simultaneously in the SBI DROP bus and is configurable on a per tributary basis in the SBI ADD bus.
Table 34
COL # ROW # 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 1 2 1-18 Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused Unused
- Transparent VT2/TU12 Format
E1#1,1 #2,1-3,21 E1#1,1 #2,1-3,21 E1#1,1 #2,1-3,21 E1#1,1 #2,1-3,21 19 V1 I I I I I I I I V2 I I I I I I I I V3 I I I I I I I I V4 I 20-81 V1 V2 V3 V4 82 V5 I I I I I I I I I I I I I I I I I I I I I I I I I I I I 83-144 145 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 146-207 208 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 209-270 -
PROPRIETARY AND CONFIDENTIAL
229
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
3 4 5 6 7 8 9
Unused Unused Unused Unused Unused Unused Unused
I I I I I I I
-
I I I I I I I
-
I I I I I I I
-
I I I I I I I
-
12.12 H-MVIP Data Format
The H-MVIP data and Channel Associated Signaling interfaces on the TEMUX are able to carry all the DS0s for 28 T1s or all timeslots for 21 E1s. When Carrying timeslots from E1s the H-MVIP frame is completely filled with 128 timeslots from four E1s but when carrying DS0s from four T1s there are not enough DS0s to completely fill the 128 byte frame. Table 35 shows how the DS0s and CAS bits of four T1s are formatted in the 128 timeslot H-MVIP frame. Table 36 shows the timeslot and CAS bit H-MVIP format when in E1 mode and not in G.747 mode. Table 37 shows the timeslot and CAS bit H-MVIP format when in G.747 mode. The CAS bits are carried in bits 5,6,7 and 8 of each byte on the CASID[1:7] and CASED[1:7] H-MVIP buses.
Table 35 Timeslot Number - Data and CAS T1 H-MVIP Format First T1 DS0 Number Second T1 DS0 Number Third T1 DS0 Number Fourth T1 DS0 Number
0-3 4-7 8-11 12-15 16-19 20-23 24-27 28-31 32-35
* *
Undefined 1 2 3 Undefined 4 5 6 Undefined
* *
Undefined 1 2 3 Undefined 4 5 6 Undefined
* *
Undefined 1 2 3 Undefined 4 5 6 Undefined
* *
Undefined 1 2 3 Undefined 4 5 6 Undefined
* *
PROPRIETARY AND CONFIDENTIAL
230
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
*
*
*
*
*
108-111 112-115 116-119 120-123 124-127
Table 36 Timeslot Number
21 Undefined 22 23 24
21 Undefined 22 23 24
21 Undefined 22 23 24
21 Undefined 22 23 24
- Data and CAS E1 H-MVIP Format with SONET/SDH E1 Mapping First E1 TS Number Second E1 TS Number Third E1 TS Number Fourth E1 TS Number
0-3 4-7 8-11 12-15 16-19
* * *
0 1 2 3 4
* * *
0 1 2 3 4
* * *
0 1 2 3 4
* * *
0 1 2 3 4
* * *
120-123 124-127
Table 37 Timeslot Number
30 31
30 31
30 31
30 31
- Data and CAS E1 H-MVIP Format in G.747 mode First E1 TS Number Second E1 TS Number Third E1 TS Number Fourth E1 TS Number
0-3 4-7 8-11 12-15 16-19
0 1 2 3 4
0 1 2 3 4
0 1 2 3 4
undefined undefined undefined undefined undefined
PROPRIETARY AND CONFIDENTIAL
231
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
* * *
* * *
* * *
* * *
* * *
120-123 124-127
30 31
30 31
30 31
undefined undefined
The H-MVIP Common Channel Signaling interface on TEMUX carries at most 63 timeslots when in E1 mode, timeslot 16 for ISDN signaling, timeslot 15 and timeslot 31 for V5.2 interfaces. In T1 mode the CCS H-MVIP interface only carries 28 full timeslots. Table 38 shows the H-MVIP format for carrying 28 common channeling signaling channels when in T1 mode. Table 39 shows the HMVIP format for carrying 63 common channeling signaling channels when in E1 mode when not in G.747 mode. Table 40 shows the H-MVIP format for carrying 63 E1 common channeling signaling channels when in G.747 mode . These formats are fixed so when a signaling or V5.2 channel is not in use the H-MVIP timeslot is undefined.
Table 38 - CCS T1 H-MVIP Format T1 Number
H-MVIP Timeslot Number
0 1 2 3 4
* * *
1 2 3 4 5
* * *
26 27 28 29
* *
27 28 undefined undefined
* *
PROPRIETARY AND CONFIDENTIAL
232
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
H-MVIP Timeslot Number *
T1 Number *
127
Table 39
undefined
- CCS E1 H-MVIP Format with SONET/SDH E1 Mapping E1 Number TS 16 E1 Number TS 15 E1 Number TS 31
H-MVIP Timeslot Number
0 1 2 3 4
* * *
1 2 3 4 5
* * *
20 21
* * *
21 undefined
* * *
31 32 33
* * *
undefined 1 2
* * *
52 53
*
21 undefined
*
PROPRIETARY AND CONFIDENTIAL
233
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
H-MVIP Timeslot Number * *
E1 Number TS 16
E1 Number TS 15 * *
E1 Number TS 31
63 64 65
* * *
undefined 1 2
* * *
84 85
* * *
21 undefined
* * *
127
undefined
PROPRIETARY AND CONFIDENTIAL
234
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Table 40
- CCS E1 H-MVIP Format in G.747 Mode E1 Number TS 16 E1 Number TS 15 E1 Number TS 31
H-MVIP Timeslot Number
0 1 2 3 4 5 6 7
* * *
1 2 3 undefined 4 5 6 undefined
* * *
24 25 26 27
* * *
19 20 21 undefined
* * *
31 32 33 34 35
* * *
undefined 1 2 3 undefined
* * *
PROPRIETARY AND CONFIDENTIAL
235
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
H-MVIP Timeslot Number
E1 Number TS 16
E1 Number TS 15
E1 Number TS 31
58 59
* * *
21 undefined
* * *
63 64 65 66 67
* * *
undefined 1 2 3 undefined
* * *
90 91
* * *
21 undefined
* * *
127
12.13 Serial Clock and Data Format
undefined
The Serial Clock and Data interfaces are able to carry the complete payload for 28 T1s or 21 E1s. Each T1 or E1 is assigned to one transmit pin and one receive data pin for the payload. As appropriate, additional pins may exist for the T1/E1 clock, signaling bits and/or frame pulse, depending on the specific interface mode selected. The formatting of these bits is outlined in greater deail in the Functional Timing section of this document. In T1 mode, all 28 sets of clock and data pins are used in each direction.
PROPRIETARY AND CONFIDENTIAL
236
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
In normal E1 mode, the first 21 sets of clock and data pins are used in each direction. The clock and data pins numbered between 22 and 28 are not defined, as the 22nd through 28th framer blocks are not used in this mode. In ITU-T G.747 mutiplexed E1 mode, every fourth set of clock and data pins are not used in each direction. (i.e. Pins 1-3, 5-7, 9-11, 13-15, 17-19, 21-23, 25-27 are defined while pins 4, 8, 12, 16, 20, 24, and 28 are not defined.) This is because the 4th, 8th, 12th, 16th, 20th, 24th and 28th framer blocks are not used in this mode.
12.14 PRGD Pattern Generation
The pattern generator can be configured to generate pseudo random patterns or repetitive patterns as shown in Figure 47 below:
Figure 47 - PRGD Pattern Generator
LENGTH PS TAP
1
2
3
32
The pattern generator consists of a 32 bit shift register and a single XOR gate. The XOR gate output is fed into the first stage of the shift register. The XOR gate inputs are determined by values written to the length register (PL[4:0]) and the tap register (PT[4:0], when the PS bit is low). When PS is high, the pattern detector functions as a recirculating shift register, with length determined by PL[4:0].
Generating and detecting repetitive patterns
When a repetitive pattern (such as 1-in-8) is to be generated or detected, the PS bit must be set to logic 1. The pattern length register must be set to (N-1), where N is the length of the desired repetitive pattern. Several examples of programming for common repetitive sequences are given below in the Common Test Patterns section. For pattern generation, the desired pattern must be written into the PRGD Pattern Insertion registers. The repetitive pattern will then be continuously
PROPRIETARY AND CONFIDENTIAL
237
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
generated. The generated pattern will be inserted in the output data stream, but the phase of the pattern cannot be guaranteed. For pattern detection, the PRGD will determine if a repetitive pattern of the length specified in the pattern length register exists in the input stream. It does so by loading the first N bits from the data stream, and then monitoring to see if the pattern loaded repeats itself error free for the subsequent 48 bit periods. It will repeat this process until it finds a repetitive pattern of length N, at which point it begins counting errors (and possibly re-synchronizing) in the same way as for pseudo-random sequences. Note that the PRGD does NOT look for the pattern loaded into the Pattern Insertion registers, but rather automatically detects any repetitive pattern of the specified length. The precise pattern detected can be determined by initiating a PRGD update, setting PDR[1:0] = 00 in the PRGD Control register, and reading the Pattern Detector registers (which will then contain the 32 bits detected immediately prior to the strobe).
Common Test Patterns
The PRGD can be configured to monitor the standardized pseudo random and repetitive patterns described in ITU-T O.151. The register configurations required to generate these patterns and others are indicated in Table 41 and Table 42 below:
PROPRIETARY AND CONFIDENTIAL
238
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Table 41 Pattern Type
- Pseudo Random Pattern Generation (PS bit = 0) TR LR IR#1 IR#2 IR#3 IR#4 TINV RINV
23 -1 24 -1 25-1 26 -1 27 -1 27 -1 (Fractional T1 LB Activate) 27 -1 (Fractional T1 LB Deactivate) 29 -1 (O.153) 210 -1 211 -1 (O.152, O.153) 215 -1 (O.151) 217 -1 218 -1 220 -1 (O.153) 220 -1 (O.151 QRSS bit=1) 221 -1 222 -1 223 -1 (O.151) 225 -1 228 -1 229 -1
00 00 01 04 00 03 03 04 02 08 0D 02 06 02 10 01 00 11 02 02 01
02 03 04 05 06 06 06 08 09 0A 0E 10 11 13 13 14 15 16 18 1B 1C
FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0 0 0 0 0 0 1 0 0 0 1 0 0 0 0 0 0 1 0 0 0
0 0 0 0 0 0 1 0 0 0 1 0 0 0 0 0 0 1 0 0 0
PROPRIETARY AND CONFIDENTIAL
239
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Pattern Type
TR
LR
IR#1
IR#2
IR#3
IR#4
TINV
RINV
231 -1
Table 42
02
1E
FF
FF
FF
FF
0
0
- Repetitive Pattern Generation (PS bit = 1) TR LR IR#1 IR#2 IR#3 IR#4 TINV RINV
Pattern Type
All ones All zeros Alternating ones/zeros Double alternating ones/zeros 3 in 24 1 in 16 1 in 8 1 in 4 Inband loopback activate Inband loopback deactivate
00 00 00 00 00 00 00 00 00 00
00 00 01 03 17 0F 07 03 04 02
FF FE FE FC 22 01 01 F1 F0 FC
FF FF FF FF 00 00 FF FF FF FF
FF FF FF FF 20 FF FF FF FF FF
FF FF FF FF FF FF FF FF FF FF
0 0 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0 0
Notes for the Pseudo Random and Repetitive Pattern Generation Tables 1. The PS bit and the QRSS bit are contained in the PRGD Control register 2. TR = PRGD Tap Register 3. LR = PRGD Length Register 4. IR#1 = PRGD Pattern Insertion #1 Register 5. IR#2 = PRGD Pattern Insertion #2 Register 6. IR#3 = PRGD Pattern Insertion #3 Register 7. IR#4 = PRGD Pattern Insertion #4 Register 8. The TINV bit and the RINV bit are contained in the PRGD Control register
PROPRIETARY AND CONFIDENTIAL
240
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
12.15 JTAG Support
The TEMUX supports the IEEE Boundary Scan Specification as described in the IEEE 1149.1 standards. The Test Access Port (TAP) consists of the five standard pins, TRSTB, TCK, TMS, TDI and TDO used to control the TAP controller and the boundary scan registers. The TRSTB input is the active-low reset signal used to reset the TAP controller. TCK is the test clock used to sample data on input, TDI and to output data on output, TDO. The TMS input is used to direct the TAP controller through its states. The basic boundary scan architecture is shown below.
Figure 48 - Boundary Scan Architecture
TDI
Boundary Scan Register Device Identification Register Bypass Register
Instruction Register and Decode
Mux DFF
TDO
TMS
Test Access Port Controller
Control Select Tri-state Enable
TRSTB TCK
PROPRIETARY AND CONFIDENTIAL
241
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
The boundary scan architecture consists of a TAP controller, an instruction register with instruction decode, a bypass register, a device identification register and a boundary scan register. The TAP controller interprets the TMS input and generates control signals to load the instruction and data registers. The instruction register with instruction decode block is used to select the test to be executed and/or the register to be accessed. The bypass register offers a singlebit delay from primary input, TDI to primary output, TDO. The device identification register contains the device identification code. The boundary scan register allows testing of board inter-connectivity. The boundary scan register consists of a shift register placed in series with device inputs and outputs. Using the boundary scan register, all digital inputs can be sampled and shifted out on primary output, TDO. In addition, patterns can be shifted in on primary input, TDI, and forced onto all digital outputs.
12.15.1 TAP Controller
The TAP controller is a synchronous finite state machine clocked by the rising edge of primary input, TCK. All state transitions are controlled using primary input, TMS. The finite state machine is described below.
PROPRIETARY AND CONFIDENTIAL
242
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Figure 49
- TAP Controller Finite State Machine
TRSTB=0 Test-Logic-Reset 1 0 1 Run-Test-Idle 0 1 Capture-DR 0 Shift-DR 1 Exit1-DR 0 Pause-DR 1 0 Exit2-DR 1 Update-DR 1 0 0 0 0 1 Select-DR-Scan 0 1 Capture-IR 0 Shift-IR 1 Exit1-IR 0 Pause-IR 1 Exit2-IR 1 Update-IR 1 0 0 0 1 1 Select-IR-Scan 0 1
All transitions dependent on input TMS
PROPRIETARY AND CONFIDENTIAL
243
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Test-Logic-Reset
The test logic reset state is used to disable the TAP logic when the device is in normal mode operation. The state is entered asynchronously by asserting input, TRSTB. The state is entered synchronously regardless of the current TAP controller state by forcing input, TMS high for 5 TCK clock cycles. While in this state, the instruction register is set to the IDCODE instruction.
Run-Test-Idle
The run test/idle state is used to execute tests.
Capture-DR
The capture data register state is used to load parallel data into the test data registers selected by the current instruction. If the selected register does not allow parallel loads or no loading is required by the current instruction, the test register maintains its value. Loading occurs on the rising edge of TCK.
Shift-DR
The shift data register state is used to shift the selected test data registers by one stage. Shifting is from MSB to LSB and occurs on the rising edge of TCK.
Update-DR
The update data register state is used to load a test register's parallel output latch. In general, the output latches are used to control the device. For example, for the EXTEST instruction, the boundary scan test register's parallel output latches are used to control the device's outputs. The parallel output latches are updated on the falling edge of TCK.
Capture-IR
The capture instruction register state is used to load the instruction register with a fixed instruction. The load occurs on the rising edge of TCK.
Shift-IR
The shift instruction register state is used to shift both the instruction register and the selected test data registers by one stage. Shifting is from MSB to LSB and occurs on the rising edge of TCK.
PROPRIETARY AND CONFIDENTIAL
244
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Update-IR
The update instruction register state is used to load a new instruction into the instruction register. The new instruction must be scanned in using the Shift-IR state. The load occurs on the falling edge of TCK. The Pause-DR and Pause-IR states are provided to allow shifting through the test data and/or instruction registers to be momentarily paused.
Boundary Scan Instructions
The following is a description of the standard instructions. Each instruction selects a serial test data register path between input, TDI and output, TDO.
BYPASS
The bypass instruction shifts data from input, TDI to output, TDO with one TCK clock period delay. The instruction is used to bypass the device.
EXTEST
The external test instruction allows testing of the interconnection to other devices. When the current instruction is the EXTEST instruction, the boundary scan register is placed between input, TDI and output, TDO. Primary device inputs can be sampled by loading the boundary scan register using the Capture-DR state. The sampled values can then be viewed by shifting the boundary scan register using the Shift-DR state. Primary device outputs can be controlled by loading patterns shifted in through input TDI into the boundary scan register using the Update-DR state.
SAMPLE
The sample instruction samples all the device inputs and outputs. For this instruction, the boundary scan register is placed between TDI and TDO. Primary device inputs and outputs can be sampled by loading the boundary scan register using the Capture-DR state. The sampled values can then be viewed by shifting the boundary scan register using the Shift-DR state.
IDCODE
The identification instruction is used to connect the identification register between TDI and TDO. The device's identification code can then be shifted out using the Shift-DR state.
PROPRIETARY AND CONFIDENTIAL
245
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
STCTEST
The single transport chain instruction is used to test out the TAP controller and the boundary scan register during production test. When this instruction is the current instruction, the boundary scan register is connected between TDI and TDO. During the Capture-DR state, the device identification code is loaded into the boundary scan register. The code can then be shifted out of the output, TDO, using the Shift-DR state.
Boundary Scan Cells
In the following diagrams, CLOCK-DR is equal to TCK when the current controller state is SHIFT-DR or CAPTURE-DR, and unchanging otherwise. The multiplexer in the center of the diagram selects one of four inputs, depending on the status of select lines G1 and G2. The ID Code bit is as listed in the Boundary Scan Register table in the JTAG Test Port section 11.2.
Figure 50
IDCODE
- Input Observation Cell (IN_CELL)
Scan Chain Out INPUT to internal logic
Input Pad
G1 G2 SHIFT-DR
I.D. Code bit CLOCK-DR
12 1 2 MUX 12 12
Scan Chain In
D C
PROPRIETARY AND CONFIDENTIAL
246
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Figure 51
- Output Cell (OUT_CELL)
Scan Chain Out
EXTEST Output or Enable from system logic IDOODE SHIFT-DR
G1 1 G1 G2 1 1 1 1 2 2 MUX 2 2 1
OUTPUT or Enable
MUX
D C
D C
I.D. code bit CLOCK-DR UPDATE-DR
Scan Chain In
Figure 52
- Bidirectional Cell (IO_CELL)
Scan Chain Out
EXTEST OUTPUT from internal logic IDCODE SHIFT-DR INPUT from pin I.D. code bit CLOCK-DR UPDATE-DR Scan Chain In
G1 1 G1 G2 12 1 2 MUX 12 12 1
INPUT to internal logic
MUX
OUTPUT to pin
D C
D C
PROPRIETARY AND CONFIDENTIAL
247
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Figure 53
- Layout of Output Enable and Bidirectional Cells
Scan Chain Out OUTPUT ENABLE from internal logic (0 = drive) INPUT to internal logic OUTPUT from internal logic
OUT_CELL
IO_CELL
I/O PAD
Scan Chain In
PROPRIETARY AND CONFIDENTIAL
248
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
13
FUNCTIONAL TIMING
13.1 DS3 Line Side Interface Timing
All functional timing diagrams assume that polarity control is not being applied to input and output data and clock lines (i.e. polarity control bits in the TEMUX registers are set to their default states).
Figure 54
RCLK
LCV
- Receive Bipolar DS3 Stream
RPOS
3 consec 0s
RNEG
The Receive Bipolar DS3 Stream diagram (Figure 54) shows the operation of the TEMUX while processing a B3ZS encoded DS3 stream on inputs RPOS and RNEG. It is assumed that the first bipolar violation (on RNEG) illustrated corresponds to a valid B3ZS signature. A line code violation is declared upon detection of three consecutive zeros in the incoming stream, or upon detection of a bipolar violation which is not part of a valid B3ZS signature.
Figure 55
RCLK RDAT RLCV
X1 BIT INFO 1 INFO 84 X2 BIT INFO 84 OR P OR M BIT C BIT INFO 1 OR F BIT INFO 2 INFO 3 INFO 4 INFO 5
- Receive Unipolar DS3 Stream
LCV INDICATION
The Receive Unipolar DS3 Stream diagram (Figure 55) shows the complete DS3 receive signal on the RDAT input. Line code violation indications, detected by an upstream B3ZS decoder, are indicated on input RLCV. RLCV is sampled each bit period. The PMON Line Code Violation Event Counter is incremented each time a logic 1 is sampled on RLCV.
PROPRIETARY AND CONFIDENTIAL
249
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Figure 56
- Transmit Bipolar DS3 Stream
TICLK TCLK TPOS TNEG
1 1 0 0 0 1 0
The Transmit Bipolar DS3 Stream diagram (Figure 56) illustrates the generation of a bipolar DS3 stream. The B3ZS encoded DS3 stream is present on TPOS and TNEG. These outputs, along with the transmit clock, TCLK, can be directly connected to a DS3 line interface unit. Note that TCLK is a flow through version of TICLK; a variable propagation delay exists between these two signals.
Figure 57 - Transmit Unipolar DS3 Stream
TICLK TCLK TDAT TMFP The Transmit Unipolar DS3 Stream diagram (Figure 57) illustrates the unipolar DS3 stream generation. The TMFP output marks the M-frame boundary, X1 bit, in the transmit stream. Note that TCLK is a flow through version of TICLK; a variable propagation delay exists between these two signals.
X1 Nib 1 Bit 4 Nib 21 Bit 1 X2 Nib 22 Bit 4 Nib 1190 Bit 1 X1 Nib 1 Bit 4
PROPRIETARY AND CONFIDENTIAL
250
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
13.2 DS3 System Side Interface Timing Figure 58
TICLK or RCLK TDATI TFPI/TMFPI TFPO/TMFPO
INFO 82 INFO 83 INFO 84
- Framer Mode DS3 Transmit Input Stream
F4
INFO 82 INFO 83 INFO 84
X1
INFO 1
INFO 2
X2
INFO 1
INFO 2
INFO 3
INFO 82 INFO 83 INFO 84
Figure 59
TGAPCLK TDATI
- Framer Mode DS3 Transmit Input Stream With TGAPCLK
INFO 83 INFO 84
INFO 1
INFO 83 INFO 84
INFO 1
INFO 2
INFO 3
INFO 1
INFO 2
INFO 3
INFO 4
INFO 81 INFO 82 INFO 83
The Framer Mode DS3 Transmit Input Stream diagram (Figure 58) shows the expected format of the inputs TDATI and TFPI/TMFPI along with TICLK and the output TFPO/TMFPO when the OPMODE[1:0] bits are set to "DS3 Framer Only mode" in the Global Configuration register. If the TXMFPI bit in the DS3 Master Unchannelized Interface Options register is logic 0, then TFPI is valid, and the TEMUX will expect TFPI to pulse for every DS3 overhead bit with alignment to TDATI. If the TXMFPI register bit is logic 1, then TMFPI is valid, and the TEMUX will expect TMFPI to pulse once every DS3 M-frame with alignment to TDATI. If the TXMFPO bit in the DS3 Master Unchannelized Interface Options register is logic 0, then TFPO is valid, and the TEMUX will pulse TFPO once every 85 TICLK cycles, providing upstream equipment with a reference DS3 overhead pulse. If the TXMFPO register bit is logic 1, then TMFPO is valid and the TEMUX will pulse TMFPO once every 4760 TICLK cycles, providing upstream equipment with a reference M-frame pulse. The alignment of TFPO or TMFPO is arbitrary. There is no set relationship between TFPO/TMFPO and TFPI/TMFPI. When the DS3 interface is loop timed by setting the LOOPT bit in the DS3 Master Data Source register, RCLK replaces TICLK as the transmit timing reference and all timing is relative to RCLK. The TGAPCLK output is available in place of TFPO/TMFPO when the TXGAPEN bit in the DS3 Master Unchannelized Interface Options register is set to logic 1, as in Figure 59. TGAPCLK remains high during the overhead bit positions. TDATI is sampled on the active edge of TGAPCLK when TXGAPEN is set to logic 1 and on the active edge of TICLK when TXGAPEN is set to logic 0. The TDATIFALL bit in the DS3 Master Unchannelized Interface Options register selects the active edge of TICLK or TGAPCLK for sampling TDATI.
PROPRIETARY AND CONFIDENTIAL
251
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Figure 60
RSCLK
- Framer Mode DS3 Receive Output Stream
RDATO INFO 82 RFPO/RMFPO ROVRHD
INFO INFO 83 84
F 4
INFO 82
INFO INFO 83 84
X 1
INFO 1
INFO 2
X 2
INFO INFO INFO 1 2 3
INFO 82
INFO INFO 84 83
Figure 61
RGAPCLK RDATO
- Framer Mode DS3 Receive Output Stream with RGAPCLK
INFO 82
INFO 83
INFO 84
INFO 82
INFO INFO 83 84
INFO 1
INFO 2
INFO INFO INFO 1 2 3
INFO 82
INFO INFO 84 83
The DS3 Framer Only Mode Receive Output Stream diagram (Figure 60) shows the format of the outputs RDATO, RFPO/RMFPO, RSCLK ROVRHD when the OPMODE[1:0] bits are set to "DS3 Framer Only mode" in the Global Configuration register. Figure 60 shows the data streams when the TEMUX is configured for the DS3 receive format. If the RXMFPO bit in the DS3 Master Unchannelized Interface Options register is logic 0, RFPO is valid and will pulse high for one RSCLK cycle on first bit of each M-subframe with alignment to the RDATO data stream. If the RXMFPO register bit is a logic 1 (as shown Figure 60), RMFPO is valid and will pulse high on the X1 bit of the RDATO data output stream. ROVRHD will be high for every overhead bit position on the RDATO data stream. Figure 61 shows the output data stream with RGAPCLK in place of RSCLK when the RXGAPEN bit in the DS3 Master Unchannelized Interface Options register set to logic 1. RGAPCLK remains high during the overhead bit positions.
PROPRIETARY AND CONFIDENTIAL
252
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
13.3 Telecom DROP Bus Interface Timing
Figure 62 shows the function of the various telecom DROP bus signals in AU3 mode. Data on LDDATA[7:0] is sampled on the rising edge of LREFCLK. The bytes forming the three STS-1 synchronous payload envelopes are identified when the LDPL signal is high. In this diagram, a negative stuff event is shown occurring on STS-1 #2 and a positive stuff event on STS-1 #3. The LDC1J1V1 signal pulses high, while LDPL is set low, to mark the C1 byte of the first STS-1 in every frame of the STS-3 transport envelope. The LDC1J1V1 signal is high when the LDPL signal is high to mark every J1 byte of each of the three STS-1 SPEs. The bytes forming the various tributary synchronous payload envelopes are identified by the LDTPL when set high. The LDV5 signal pulses high to mark the V5 bytes of each outgoing tributaries. LDTPL and LDV5 are invalid when LDPL is set low. The three STS-1 SPEs can each have different alignments to the STS-3 transport envelope and the alignment is changing for two of the STS-1 SPEs (STS-1 #2 and #3) due to the pointer justification events shown.
Figure 62
LREFCLK LDC1J1 **** LDPL LDV5 LDTPL LDDATA[7:0]
INVALID INVALID IV IV
- Telecom DROP Bus Timing - STS-1 SPEs / AU3 VCs
INVALID
INVALID
IV
IV
A1 A1 A1 A2 A2 A2 C1 C1 C1 J1 C2 H4 Vx
H1 H1 H1 H2 H2 H2 H3 H4 H3 G1
V5
STS-1 #1 SPE J1 byte Last H4 byte in tributary multiframe Any V1 - V4 byte TU#1, STS-1 #1
Negative stuff for STS-1 #2 SPE which happens to carry a non-final H4 byte Positive stuff for STS-1 #3 SPE V5 byte as marked by OTV5
PROPRIETARY AND CONFIDENTIAL
253
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
The LDV5 and LDTPL signals are optional when using the ingress VTPP within the TEMUX which will regenerate the LDV5 and LDTPL signals from LDC1J1V1, LDPL and the pointers within LDDATA[7:0]. In order to bypass the ingress VTPP, the data on the Telecom drop bus must be locked such that all three STS-1 SPEs are aligned to the STS-3 transport envelope with the J1 bytes immediately following the C1 bytes. This is shown in Figure 63.
Figure 63
LREFCLK LDC1J1 LDPL LDV5 LDTPL LDDATA[7:0]
A2 C1 C1 C1 J1 J1 J1 V1 V1 V1 V1 V1 V1 V1 H1 H1 H1 H2 H2 H2 H3 H3 H3 J2 V5
- Telecom DROP Bus Timing - Locked STS-1 SPEs / AU3 VCs
****
Implicit location of STS-1 SPE J1 bytes V1 byte VT #1, STS-1 #1 V1 byte VT #1, STS-1 #2 V1 byte VT #1, STS-1 #3
No stuff events possible J2 byte VT #1, STS-1 #1 V5 byte VT #1, STS-1 #2 V1 bytes VT #2
PROPRIETARY AND CONFIDENTIAL
254
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Figure 64 shows the function of the various telecom DROP bus signals in AU4 mode. Data on LDDATA [7:0] is sampled on the rising edge of LREFCLK. The bytes forming the VC4 virtual container are identified by the setting the LDPL signal high. The LDC1J1V1 signal pulses high, while LDPL is set low, to mark the single C1 byte in every frame of the AU4 transport envelope. The LDC1J1V1 signal is set high again with LDPL high to mark the J1 byte of the VC4. The bytes forming the various tributary synchronous payload envelopes are identified by the LDTPL signal being set high. The LDV5 signal pulses high to mark the V5 bytes of each outgoing tributaries.
Figure 64
LREFCLK LDC1J1 **** LDPL LDV5 LDT PL LDDATA [7:0]
INVALID
- Telecom DROP Bus Timing - AU4 VC
INVALID
A1 A2 A2 A2 C1 X X
V5
Z7
J1
NP NP NP
V1 V1 V1
National bytes V5 byte TUG3 #1 Z7 byte TUG3 #1
J1 byte VC 4 First NPI byte TUG3 #1 V1 byte TU #1, TUG2 #1, TUG3 #1
The LDV5 and LDTPL signals are optional when using the ingress VTPP within the TEMUX which will regenerate the LDV5 and LDTPL signals from LDC1J1V1, LDPL and the pointers within LDDATA[7:0]. In order to bypass the ingress VTPP, the position of the single J1 byte and the VC4 is implicitly defined by the C1 byte position. In the locked AU4 mode, the VC4 is defined to be aligned to the AU4 transport envelope such that the J1 byte occupies the first available payload byte after the C1 byte, and no pointer justifications are possible.
PROPRIETARY AND CONFIDENTIAL
255
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
13.4 Telecom ADD Bus Interface Timing
Figure 65 shows the function of the telecom ADD bus signals in AU3 mode. Data on LADATA[7:0] is updated on the rising edge of LREFCLK. The LAC1 input is sampled on the rising edge of LREFCLK and aligns all devices on the ADD bus by marking the first C1 byte of the first STS-1 in every fourth STS-3 transport envelope. LAC1 pulses every fourth STS-3 to indicate tributary multiframe alignment on the ADD bus. The bytes forming the three STS-1 synchronous payload envelopes are identified when the LAPL signal is high. The LAC1J1V1 signal pulses high, while LAPL is set low, to mark the C1 byte of the first STS-1 in every frame of the STS-3 transport envelope. The LAC1J1V1 signal is high when the LAPL signal is high to mark every J1 byte of each of the three STS-1 SPEs. The three STS-1 SPEs are fixed at two different alignments to the STS-3 transport envelope. The first is shown in Figure 65 in which the J1 bytes follow immediately after the C1 bytes. The second alignment is at SPE pointer location zero where the J1 bytes follow immediately after the H3 bytes. The LAC1 signal is updated on the rising edge of LREFCLK. It is output during when the TEMUX is outputing valid tributary data onto the ADD bus. It is asserted high for all bytes making up a tributary and is asserted low during overhead bytes.
Figure 65
LREFCLK LAC1 LAOE ****
- Output Bus Timing - Locked STS-1 SPEs / AU3 VCs
LAC1J1V1 LAPL LADATA[7:0]
A2 C1 C1 C1 J1 J1 J1 V1 V1 V1 V1 V1 V1 V1 H1 H1 H1 H2 H2 H2 H3 H3 H3 J2 V5
Implicit location of STS-1 SPE J1 bytes V1 byte VT #1, STS-1 #1 V1 byte VT #1, STS-1 #2 V1 byte VT #1, STS-1 #3
No stuff events possible J2 byte VT #1, STS-1 #1 V5 byte VT #1, STS-1 #2 V1 bytes VT #2
PROPRIETARY AND CONFIDENTIAL
256
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Figure 66 shows the function of the TEMUX telecom ADD bus when operating in AU4 mode. In AU4 mode, the position of the single J1 byte and the VC4 is implicitly defined by the LAC1 byte position. The VC4 is defined to be aligned to the AU4 transport envelope such that the J1 byte occupies the first available payload byte after the C1 byte. No pointer justification events take place on the ADD bus. LAC1J1V1 pulses high to mark the first C1 byte, the J1 byte and the third byte after J1 of the first tributary in the AU4 stream. LAPL identifies the payload bytes on LADATAD[7:0].
Figure 66
LREFCLK LAC1 **** LAOE LAC1J1V1 LAPL LADATA[7:0]
A2 C1 X X J1 R R R R R R V1 H4 R R R R R R V5 Z6
- Output Bus Timing - Locked AU4 VC Case
National bytes Implicit location of VC4 J1 byte First R column of TUG3 #1 V1 byte TU #1, TUG2 #1, TUG3 #1
Last H4 byte in tributary multiframe
Fixed Stuff Columns V5 byte TU #1, TUG2 #1, TUG3 #1 Z6 byte TU #1, TUG2 #1, TUG3 #3
13.5 SONET/SDH Serial Alarm Port Timing
The timing relationships of the signals related to the remote serial alarm port are shown in Figure 67. The remote serial alarm port clocks, RADEASTCK and RADWESTCK, are nominally 9.72 MHz clocks but can range from 1.344 MHz to 10 MHz. The remote serial alarm port frame pulses, RADEASTFP and RADWESTFP, mark the first BIP-2 error bit (B1 in Figure 67) of the first tributary (TU #1 of TUG2 #1, TUG3 #1) on RADEAST and RADWEST, respectively. The frame pulses must be set high to mark every first BIP-2 error bit of the first tributary. Tributaries on RADEAST and RADWEST are arranged in the order of transmission of an STM-1 stream as defined in the references. I.e., TU #1 of
PROPRIETARY AND CONFIDENTIAL
257
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
TUG2 #1 in TUG3 #1, TU#1 of TUG2 #1 in TUG3 #2, TU#1 of TUG2 #1 in TUG3 #3, TU#1 of TUG2 #2 in TUG3 #1, ... TU #1 of TUG2 #7 in TUG3 #3, TU #2 of TUG2 #1 in TUG3 #1, ... TU #2 of TUG2 #7 in TUG3 #3, TU #3 of TUG2 #1 in TUG3 #1, ... TU #4 of TUG2 #7 in TUG3 #3. Timeslot assignment on RADEAST and RADWEST is unrelated to the configuration of the TUG2. Timeslots are always reserved for four tributaries in every TUG2 even if it is configured for tributaries with higher bandwidth than TU11, such as TU12. At timeslots devoted to non-existent tributaries, for example, tributary 4 of a TUG2 configured for TU12, RADEAST and RADWEST will be ignored. Each tributary in the remote serial alarm port is allocated eight timeslots. The first two timeslots, labeled B1 and B2 in Figure 67, reports the two possible BIP-2 errors in the tributary payload frame. An alarm contributing to remote defect indications is reported in the third timeslot and is labeled D in Figure 67. The timeslot labeled F report alarms contributing to remote failure indications. In extended RDI mode, the D and F bits are considered as two bit codepoint and will be reported on the RDI and RFI signals. Out of extended RDI mode, the D and F bits are independent. The remaining four timeslots are unused and are ignored.
Figure 67
RADEASTCK/ RADWESTCK
TU #1, TUG 2 #1 X TU #1 , TUG 2 #2 TUG2 #3 TUG3 TUG3 TUG3 TUG3 TUG3 TUG3 TUG3 TUG3 #1 #2 #3 #1 #2 #3 #1 #2
- Remote Serial Alarm Port Timing
...
TUG2 #6
TU #4, TUG 2 #7 X
TUG3 TUG3 TUG3 TUG3 TUG3 #2 #3 #1 #2 #3
RADEASTFP/ RADWESTFP RADEASTCK/ RADWESTCK RADEASTFP/ RADWESTFP
TU #1, TUG2 #1, TUG3 #1 TU #1, TUG2 #1, TUG3 #2
X B1 B2 D F X X X
TU #1, T UG2 #1, TUG3 #3
X B1 B2 D F X X X
TU #1, TUG2 #2, TUG3 #1
X B1 B2 D F X X X
RADEAST/ RADWEST
X B1 B2 D
F
X
X
X
PROPRIETARY AND CONFIDENTIAL
258
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
13.6 SBI DROP Bus Interface Timing Figure 68
SREFCLK SC1FP SDDATA[7:0] SDPL SDV5 SDDP SBIACT C1
- SBI DROP Bus T1/E1 Functional Timing
*** *** *** *** *** *** ***
V3
V3
V3 DS0#4. V5 DS0#9.
Figure 68 illustrates the operation of the SBI DROP Bus, using a negative justification on the second to last V3 octet as an example. The justification is indicated by asserting SDPL high during the V3 octet. The timing diagram also shows the location of one of the tributaries by asserting SDV5 high during the V5 octet. The SBIACT signal is shown for the case in which TEMUX is driving SPE#1 onto the SBI DROP bus.
Figure 69
SREFCLK SC1FP SDDATA[7:0 ] SDPL SDV5 SDDP SBIACT C1
- SBI DROP Bus DS3 Functional Timing
*** *** *** *** *** *** ***
H3
H3
H3
DS-3 #1 DS-3 #2 DS-3 #3DS-3 #1
Figure 69 shows three DS-3 tributaries mapped onto the SBI bus. A negative justification is shown for DS-3 #2 during the H3 octet with SDPL asserted high. A positive justification is shown for DS-3#1 during the first DS-3#1 octet after H3 which has SDPL asserted low. The SBIACT signal is shown for the case in which TEMUX is driving SPE#2 (DS-3#2) onto the SBI DROP bus.
PROPRIETARY AND CONFIDENTIAL
259
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
13.7 SBI ADD Bus Interface Timing
The SBI ADD bus functional timing for the transfer of tributaries whether T1/E1 or DS3 is the same as for the SBI DROP bus. The only difference is that the SBI ADD bus has one additional signal: the SAJUST_REQ output. The SAJUST_REQ signal is used to by the TEMUX in SBI master timing mode to provide transmit timing to SBI link layer devices.
Figure 70
SREFCLK SC1FP SADATA[7:0] SAPL SAV5 SADP SAJUST_REQ C1
- SBI ADD Bus Justification Request Functional Timing
*** *** *** *** *** *** ***
H3
H3
H3
DS-3 #1 DS-3 #2 DS-3 #3DS-3 #1
Figure 70 illustrates the operation of the SBI ADD Bus, using positive and negative justification requests as an example. (The responses to the justification requests would take effect during the next multi-frame.) The negative justification request occurs on the DS-3#3 tributary when SAJUST_REQ is asserted high during the H3 octet. The positive justification occurs on the DS-3#2 tributary when SAJUST_REQ is asserted high during the first DS-3#2 octet after the H3 octet.
13.8 Egress H-MVIP Link Timing
The timing relationship of the common 8M H-MVIP clock, CMV8MCLK, frame pulse clock, CMVFPC, data, MVED[x], CASED[x] or CCSED, and frame pulse, CMVFPB, signals of a link configured for 8.192 Mbps H-MVIP operation with a type 0 frame pulse is shown in Figure 71. The falling edges of each CMVFPC are aligned to a falling edge of the corresponding CMV8MCLK for 8.192 Mbps HMVIP operation. The TEMUX samples CMVFPB low on the falling edge of CMVFPC and references this point as the start of the next frame. The TEMUX samples the data provided on MVED[x], CASED[x] and CCSED at the 3/4 point of the data bit using the rising edge of CMV8MCLK as indicated for bit 1 (B1) of time-slot 1 (TS 1) in Figure 71. B1 is the most significant bit and B8 is the least significant bit of each octet.
PROPRIETARY AND CONFIDENTIAL
260
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Figure 71
CMV8MCLK (16 MHz) CMVFPC (4 MHz)
- Egress 8.192 Mbps H-MVIP Link Timing
CMVFPB MVED[x] CASED[x] CCSED
B8 TS 127
B1
B2
B3
B4 TS 0
B5
B6
B7
B8
B1 TS 1
13.9 Ingress H-MVIP Link Timing
The timing relationship of the common 8M H-MVIP clock, CMV8MCLK, frame pulse clock, CMVFPC, data, MVID[x], CASID[x] or CCSID, and frame pulse, CMVFPB, signals of a link configured for 8.192 Mbps H-MVIP operation with a type 0 frame pulse is shown in Figure 72. The falling edges of each CMVFPC are aligned to a falling edge of the corresponding CMV8MCLK for 8.192 Mbps HMVIP operation. The TEMUX samples CMVFPB low on the falling edge of CMVFPC and references this point as the start of the next frame. The TEMUX updates the data provided on MVID[x], CASID[x] and CCSID on every second falling edge of CMV8MCLK as indicated for bit 2 (B2) of time-slot 1 (TS 1) in Figure 72. The first bit of the next frame is updated on MVID[x], CASID[x] and CCSID on the falling CMV8MCLK clock edge for which CMVFPB is also sampled low. B1 is the most significant bit and B8 is the least significant bit of each octet.
Figure 72
CMV8MCLK (16 MHz) CMVFPC (4 MHz)
- Ingress 8.192 Mbps H-MVIP Link Timing
CMVFPB MVID[x] CASID[x] CCSID
B8 TS 127
B1
B2
B3
B4 TS 0
B5
B6
B7
B8
B1 TS 1
PROPRIETARY AND CONFIDENTIAL
261
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
13.10 Egress Serial Clock and Data Interface Timing
By convention in the following functional timing diagrams, the first bit transmitted in each channel shall be designated bit 1 and the last shall be designated bit 8. Each of the Ingress and Egress Master and Clock Modes apply to both T1 and E1 configurations with the exception of the 2.048MHz T1 Clock Slave Modes.
Figure 73 - T1 Egress Interface Clock Master: NxChannel Mode
Channel 24 Channel 1
ED[x] ECLK[x]
Don't Care
12 345 678
12 345 678
Figure 74
ED[x] ECLK[x]
- E1 Egress Interface Clock Master : NxChannel Mode
Don't Care 123456 78 12345 678
Timeslot 23
Timeslot 25
The Egress Interface Options register is programmed to select NxChannel mode. The TPSC egress control bytes are programmed to insert the desired channels. In Figure 73, the egress control bytes for T1 channels 1 and 24 are configured to insert these channels. In Figure 74, the egress control bytes for E1 channels 23 and 25 are configured to insert these channels. ECLK[x] is gapped so that it is only active for those channels with the associated IDLE_CHAN bit cleared (logic 0). The remaining channels (with IDLE_CHAN set) contain the per-channel idle code as defined in the associated Idle Code byte. When the EDE bit in the T1/E1 Serial Interface Configuration register is set to logic 0, then ED[x] is sampled on the falling edge of ECLK[x], and the functional timing is described by Figure 73 with the ECLK[x] signal inverted.
PROPRIETARY AND CONFIDENTIAL
262
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Figure 75
- T1 and E1 Egress Interface Clock Master: Clear Channel Mode
ECLK[x] ED[x]
8 12 34 5 6 7 812 3 45 6 7 8 1 2 34 56 78
The Egress Interface is configured for the Clock Master: Clear Channel mode by writing to EMODE[2:0] in theT1/E1 Egress Serial Interface Mode Select register. ED[x] is sampled on the rising edge of the ECLK[x] output. When the the EDE bit in the T1/E1 Serial Interface Configuration register is set to logic 0, then ED[x] is sampled on the falling edge of ECLK[x], and the functional timing is described by Figure 75 with the ECLK[x] signal inverted. Figure 76
CECLK CEFP ED[x] EFP[x] Channel 24 Channel 1 F-bit or Parity Channel 2 Channel 24 Channel 1 F-bit or Parity
12 34 5 6 7 8F12 3 45 6 7 8 1 2 34 56 78 12 345678F12345678
- T1 Egress Interface Clock Slave: EFP Enabled mode
Figure 77
CECLK CEFP ED[x] EFP[x]
- E1 Egress Interface Clock Slave : EFP Enabled Mode
1 2 3 4 5 6 7 81 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1
12 3 45 67 81 2 3 45 6 78 1
Timeslot 31 Timeslot 0 Parity bit (if enabled)
Timeslot 1
Timeslot 31 Timeslot 0 Parity bit (if enabled)
The Egress Interface is configured for the Clock Slave: EFP Enabled mode by writing to EMODE[2:0] in theT1/E1 Egress Serial Interface Mode Select register. ED[x] is sampled on the active edge of CECLK and EFP[x] is updated on the falling edge of CECLK.
PROPRIETARY AND CONFIDENTIAL
263
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
In T1 mode, Figure 76, the CEMFP bit is written to logic 1 in the Master Egress Slave Mode Serial Interface Configuration register, so that CEFP must pulse once every 12 or 24 frames (for SF and ESF, respectively) on the first frame bit of the multiframe. If parity checking is enabled, a parity bit should be inserted on ED[x] in the first bit of each frame. The EFP[x] output will pulse high to mark the F-bit of each frame in order to indicate frame alignment to an upstream device. EFP[x] may be configured to mark superframe alignment instead by setting the EMFP bit in the T1/E1 Serial Interface Configuration register. In E1 mode EFP[x] may be chosen to indicate alignment of every frame or the composite CRC and Signaling multiframe alignment as shown in Figure 77, by setting the EMFP bit in the T1/E1 Serial Interface Configuration register. If parity checking is enabled, a parity bit should be inserted on ED[x] in the first bit of each frame. Figure 78
CECLK CEFP ED[x] ESIG[x]
1 2 3 4 5 6 7 8F 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 A BCD A BCD A BCD 12 3 45 67 8F1 2 3 45 6 78 A BC D A BCD
- T1 Egress Interface Clock Slave: External Signaling mode
Channel 24 Channel 1 F-bit or Parity
Channel 2
Channel 24 Channel 1 F-bit or Parity
Figure 79
CECLK CEFP ED[x] ESIG[x]
- E1 Egress Interface Clock Slave : External Signaling Mode
12 34 5 6 7 812 3 45 6 7 8 1 2 34 56 78 ABCD ABCD
12 3 45 67 81 2 3 45 6 78 1 A BC D
Timeslot 31 Timeslot 0 Parity bit (if enabled)
Timeslot 1
Timeslot 31 Timeslot 0 Parity bit (if enabled)
The Egress Interface is configured for the Clock slave: External Signaling Mode by writing to EMODE[2:0] in theT1/E1 Egress Serial Interface Mode Select register. ED[x] is clocked in on the active edge of CECLK. Frame alignment is specified by pulses on CEFP. ESIG[x] should carry the signaling bits for each channel in bits 5,6,7 and 8. These signaling bits will be inserted into the data
PROPRIETARY AND CONFIDENTIAL
264
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
stream by the T1 or E1 transmitter. If parity checking is enabled, a parity bit should be inserted on ED[x] and ESIG[x] in the first bit of each frame. The parity operates on all bits in the ED[x] and ESIG[x] streams, including the unused bits on ESIG[x].
Figure 80
- T1 Egress Interface 2.048 MHz Clock Slave: EFP Enabled Mode
CECLK CEFP ED[x] EFP[x]
F
Don't Care
1 2 3 4 5 67 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
Don't Care
1 2 34 5 6 7 8
F-Bit or Parity
Channel 1 Frame 1
Channel 2 Frame 1
Channel 3 Frame 1
"filler"
Channel 4 Frame 1
CECLK CEFP ED[x] EFP[x]]
Ch24 Ch1 Ch2 Ch3 Ch4 Ch5 Ch6 Ch7 Ch23 Ch24 Ch1
The Egress Interface is configured for the Clock Slave: EFP Enabled Mode by writing to EMODE[2:0] in theT1/E1 Egress Serial Interface Mode Select register. The 2.048 MHz internally gapped clock mode is selected by writing CECLK2M to logic 1 in the Master Egress Slave Mode Serial Interface register. In Figure 80, CEFP is configured for superframe alignment by writing CEMFP to logic 1 in the Master Egress Slave Mode Serial Interface register, so that the CEFP input must pulse once every 12 or 24 frames (for SF and ESF, respectively) on the first F-bit of the multiframe to specify superframe alignment, instead of once every frame to specify frame alignment. If parity checking is enabled, a parity bit should be inserted on ED[x] in the first bit of each frame. The EFP[x] output will pulse high to mark the F-bit of each frame in order to indicate frame alignment to an upstream device. EFP[x] may be configured to mark superframe alignment instead by setting the EMFP bit in the T1/E1 Serial Interface Configuration
PROPRIETARY AND CONFIDENTIAL
265
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
register. The values of the don't-care bits are not important, except that they will be used in the backplane parity check if it is enabled. Figure 81 - T1 Egress Interface 2.048 MHz Clock Slave: External Signaling Mode
CECLK CEFP ED[x] ESIG[x]
F
Don't Care Don't Care
1 2 3 4 5 67 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 ABCD ABCD ABCD
Don't Care Don't Care
1 2 34 5 6 7 8 AB CD
F-Bit or Parity
Channel 1
Channel 2
Channel 3
"filler"
Channel 4
CECLK CEFP ED[x] ESIG[x]
Ch24 Ch1 Ch2 Ch3 Ch4 Ch5 Ch6 Ch7 Ch23 Ch24 Ch1
The Egress Interface is configured for the 2.048 MHz Clock Slave: External Signaling Mode by writing to EMODE[2:0] in theT1/E1 Egress Serial Interface Mode Select register. The 2.048 MHz internally gapped clock mode is selected by writing CECLK2M to logic 1 in the Master Egress Slave Mode Serial Interface register. In the illustrated case, CEFP specifies frame alignment and is required to pulse high for one cycle every frame. ESIG[x] should carry the signaling bits for each channel in bits 5,6,7 and 8; the signaling bits will be inserted into the data stream by the transmitter. If parity checking is enabled, a parity bit should be inserted on ED[x] and ESIG[x] in the first bit of each frame. The values of the don't-care bits are not important, except that they will be used in the backplane parity check if it is enabled. Figure 82 - T1 and E1 Egress Interface Clock Slave: Clear Channel Mode
ECLK[x] ED[x]
8 12 34 5 6 7 812 3 45 6 7 8 1 2 34 56 78
PROPRIETARY AND CONFIDENTIAL
266
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
The Egress Interface is configured for the Clock Slave: Clear Channel mode by writing to EMODE[2:0] in theT1/E1 Egress Serial Interface Mode Select register. ED[x] is clocked in on the rising edge of the ECLK[x] input. When the EDE bit in the T1/E1 Serial Interface Configuration register is set to logic 0, then ED[x] is sampled on the falling edge of ECLK[x], and the functional timing is described by Figure 82 with the ECLK[x] signal inverted. 13.11 Ingress Serial Clock and Data Interface Timing Figure 83
ICLK[x] IFP[x] ID[x]
123456 78F1234567812345678 12345678F12345678
- T1 Ingress Interface Clock Master : Full Channel Mode
Channel 24 Channel 1 F-bit or Parity
Channel 2
Channel 24 Channel 1 F-bit or Parity
Figure 84
ICLK[x] IFP[x] ID[x]
- E1 Ingress Interface Clock Master : Full Channel Mode
1 23 456 7812 345 6 7 812 34 56 7 8
12345678123456781
Timeslot 31 Timeslot 0 Parity Bit (if enabled)
Timeslot 1
Timeslot 31 Timeslot 0 Parity Bit (if enabled)
The IMODE[1:0] bits in the T1/E1 Ingress Serial Interface Mode Select register are programmed to select the Clock Master: Full Channel mode. IFP[x] is set high for one ICLK[x] period every frame. When the IMFP bit in the T1/E1 Serial Interface Configuration register are set to 1, IFP[x] pulses on the superframe frame boundaries (i.e. once every 12 or 24 frame periods when configured for T1 operation or once every CRC or signaling multiframe when configured for E1 operation). The IMFPCFG[1:0] bits select whether IFP[x] indicates E1 CRC, signaling or both CRC and signaling multiframe boundaries. If ALTIFP=1, IFP[x] pulses on every second frame or the multiframe boundary.
PROPRIETARY AND CONFIDENTIAL
267
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Figure 85
IFP[x] ID[x] ICLK[x]
- T1 Ingress Interface Clock Master: NxChannel Mode
Don't Care
123456 78
12345 678
Figure 86
IFP[x] ID[x] ICLK[x]
- E1 Ingress Interface Clock Master: NxChannel Mode
Don't Care
123456 78
12345 678
Timeslot 31
Timeslot 1
The IMODE[1:0] bits in the T1/E1 Ingress Serial Interface Mode Select register are programmed to select NxChannel mode. The RPSC ingress control bytes are programmed to extract the desired channels. In Figure 85, the ingress control bytes for T1 channels 2 and 24 are extracted. In Figure 86, the ingress control bytes for E1 channels 31 and 1 are extracted. ICLK[x] is gapped so that it is only active for those channels with the associated DTRKC bit set to 0. If either IMFP or ALTIFP is set, then IFP[x] will pulse only during the appropriate frames. When the IDE bit in the T1/E1 Serial Interface Configuration register bit is set, then ID[x] is updated on the rising edge of ICLK[x] and the functional timing is described by with ICLK[x] inverted. Figure 87 - T1 and E1 Ingress Interface Clock Master: Clear Channel Mode
I CLK[x] I D[x]
8 12 34 5 6 7 812 3 45 6 7 8 1 2 34 56 78
The Ingress Interface is configured for the Clock Slave: Clear Channel mode by writing to IMODE[1:0] in the T1/E1 Ingress Serial Interface Mode Select register. ID[x] is updated on the falling edge of the ICLK[x] input. When the IDE bit in the T1/E1 Serial Interface Configuration register is set to logic 1, then ID[x] is
PROPRIETARY AND CONFIDENTIAL
268
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
updated on the rising edge of ICLK[x], and the functional timing is described by Figure 87 with the ICLK[x] signal inverted. Figure 88
CICLK CIFP ID[x] ISIG[x]
1 2 3 4 5 6 7 8F 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 A BCD A BCD A BCD 12 3 45 67 8F1 2 3 45 6 78 A BC D A BCD
- T1 Ingress Interface Clock Slave: External Signaling Mode
Channel 24 Channel 1 F-bit or Parity
Channel 2
Channel 24 Channel 1 F-bit or Parity
Figure 89
CICLK CIFP ID[x] ISIG[x]
- E1 Ingress Interface Clock Slave: External Signaling Mode
1234 5678123456781 23456 78 ABCD ABCD
12 3 45 67 8 1 2 3 45 6 781 A BCD
Timeslot 31
Timeslot 0
Timeslot 1
Timeslot 31
Timeslot 0
The Ingress Interface is programmed for Clock Slave mode by setting the IMODE[1:0] bits in the T1/E1 Ingress Serial Interface Mode Select register. ID[x] is timed to the active edge of CICLK, and is frame-aligned to CIFP. CIFP need not be provided every frame. ID[x] and ISIG[x] may be configured to carry a parity bit during the first bit of each frame. In External Signaling Mode, ISIG[x] is active and is aligned as shown.
PROPRIETARY AND CONFIDENTIAL
269
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Figure 90
- T1 Ingress Interface 2.048 MHz Clock Slave: External Signaling Mode
CICLK CIFP ID[x] ISIG[x]
F
Don't Care Don't Care
1 2 3 4 5 67 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 ABCD ABCD ABCD
Don't Care Don't Care
1 2 34 5 6 7 8 AB C D
F-Bit or Parity
Channel 1
Channel 2
Channel 3
"filler"
Channel 4
CICLK CIFP ID[x] ISIG[x]
Ch24 Ch1 Ch2 Ch3 Ch4 Ch5 Ch6 Ch7 Ch23 Ch 24 Ch1
The Ingress Interface is programmed for Clock Slave mode by setting the IMODE[1:0] in the T1/E1 Ingress Serial Interface Mode Select register. The 2.048 MHz internally-gapped clock mode is selected by setting the CICLK2M bit to logic 1 in the Master Ingress Slave Mode Serial Interface Configuration register. ID[x] is timed to the active edge of CICLK, and is frame-aligned to CIFP. CIFP need not be provided every frame. ID[x] and ISIG[x] may be configured to carry a parity bit during the first bit of each frame. The values of the filler bits will depend on the exact configuration of the TEMUX, and they will be included in the parity calculation.
PROPRIETARY AND CONFIDENTIAL
270
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
14
ABSOLUTE MAXIMUM RATINGS Maximum rating are the worst case limits that the device can withstand without sustaining permanent damage. They are not indicative of normal mode operation conditions. Table 43 Parameter Ambient Temperature under Bias Storage Temperature Supply Voltage Supply Voltage Supply Voltage Voltage on Any Pin (note 3) Static Discharge Voltage Latch-Up Current DC Input Current Lead Temperature Junction Temperature Notes on Power Supplies: 1. VDD3.3 and VDDQ should power up before VDD2.5. 2. VDD3.3 and VDDQ should not be allowed to drop below the VDD2.5 voltage level except when VDD2.5 is not powered. 3. All pins on the TEMUX are 5V tolerant. TJ IIN TST VDD2.5 VDD3.3 VDDQ VIN - Absolute Maximum Ratings Symbol Value -40 to +85 -40 to +125 -0.3 to + 3.5 -0.3 to + 4.6 -0.3 to + 4.6 -0.3 to + 5.5 1000 100 20 +230 +150 Units C C VDC VDC VDC VDC V mA mA C C
PROPRIETARY AND CONFIDENTIAL
271
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
15
D.C. CHARACTERISTICS TA = -40C to +85C, VDD3.3 = 3.3V 10%, VDD2.5 = 2.5V 8% (Typical Conditions: TA = 25C, VDD3.3 = 3.3V, VDDQ = 3.3V, VDD2.5 = 2.5V) Table 44
Symbol VDD3.3 VDDQ VDD2.5 VIL VIH VOL
- D.C. Characteristics
Parameter Power Supply Power Supply Power Supply Input Low Voltage Input High Voltage Output or Bidirectional Low Voltage Min 2.97 2.97 2.3 -0.5 2.0 Typ 3.3 3.3 2.5 Max 3.63 3.63 2.7 0.6 5.5 0.4 Units Volts Volts Volts Volts Volts Volts Guaranteed Input LOW Voltage Guaranteed Input HIGH Voltage VDD = min, IOL = -4mA for D[7:0], LAOE, RECVCLK1, RECVCLK2, MVID[7:0], CASID[7:0], CCSID, TCLK, TPOS/TDAT, TNEG/TMFP, RGAPCLK/RSCLK, RDATAO, RFPO/RMFPO, ROVRHD, TFPO/TMFPO/TGAPCLK, SBIACT, IOL = -8mA for SDDATA[7:0], SDDP, SDPL, SDV5, SAJUST_REQ, SC1FP, LAC1J1V1, LADATA[7:0], LADP, LAPL, IOL = -2mA for others. Note 3 Conditions
PROPRIETARY AND CONFIDENTIAL
272
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Symbol VOH
Parameter Output or Bidirectional High Voltage
Min 2.4
Typ
Max
Units Volts
Conditions VDD = min, IOH = -4mA for D[7:0], LAOE, RECVCLK1, RECVCLK2, MVID[7:0], CASID[7:0], CCSID, TCLK, TPOS/TDAT, TNEG/TMFP, RGAPCLK/RSCLK, RDATAO, RFPO/RMFPO, ROVRHD, TFPO/TMFPO/TGAPCLK, SBIACT, IOH = -8mA for SDDATA[7:0], SDDP, SDPL, SDV5, SAJUST_REQ, SC1FP, LAC1J1V1, LADATA[7:0], LADP, LAPL, IOH = -2mA for others. Note 3
VT+
Reset Input High Voltage
2.0
5.5
Volts
TTL Schmidt
VT-
Reset Input Low Voltage
-0.2
0.6
Volts
VTH
Reset Input Hysteresis Voltage
1.2
0.5
Volts
IILPU IIHPU IIL IIH CIN
Input Low Current Input High Current Input Low Current Input High Current Input Capacitance
+10 -10 -10 -10 5
+100 +10 +10 +10
A A A A pF
VIL = GND. Notes 1, 3,4 VIH = VDD. Notes 1, 3 VIL = GND. Notes 2, 3 VIH = VDD. Notes 2, 3 Excluding Package, Package Typically 2 pF
COUT
Output Capacitance
5
pF
Excluding Package, Package Typically 2 pF
CIO
Bidirectional Capacitance
5
pF
Excluding Package, Package Typically 2 pF
IDDOP1
Operating Current
30
270
mA mA
VDD2.5 = 2.7V VDD3.3 = 3.63 V Outputs Unloaded, DS3 to M13 multiplexing, SBI backplane with HMVIP CAS mode.
PROPRIETARY AND CONFIDENTIAL
273
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Symbol IDDOP2
Parameter Operating Current
Min
Typ
Max 370
Units mA mA
Conditions VDD2.5 = 2.7V VDD3.3 = 3.63 V Outputs Unloaded, Telecom to VT mapping, SBI backplane with HMVIP CAS mode.
30
IDDOP3
Operating Current 30
360
mA mA
VDD2.5 = 2.7V VDD3.3 = 3.63 V Outputs Unloaded, Telecom to DS3 mapping, DS3 framing, M13 mutiplexing, SBI backplane with HMVIP CAS mode.
Notes on D.C. Characteristics: 1. Input pin or bi-directional pin with internal pull-up resistor. 2. Input pin or bi-directional pin without internal pull-up resistor 3. Negative currents flow into the device (sinking), positive currents flow out of the device (sourcing). 4. Typical values are given as a design aid. The product is not tested to the typical values given in the data sheet.
PROPRIETARY AND CONFIDENTIAL
274
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
16
MICROPROCESSOR INTERFACE TIMING CHARACTERISTICS (TA = -40C to +85C, VDD3.3 = 3.3V 10%, VDD2.5 = 2.5V 8%) Table 45 Symbol tSAR tHAR tSALR tHALR tVL tSLR tHLR tPRD tZRD tZINTH - Microprocessor Interface Read Access Parameter Address to Valid Read Set-up Time Address to Valid Read Hold Time Address to Latch Set-up Time Address to Latch Hold Time Valid Latch Pulse Width Latch to Read Set-up Latch to Read Hold Valid Read to Valid Data Propagation Delay Valid Read Negated to Output Tri-state Valid Read Negated to Output Tri-state Min 10 5 10 10 20 0 5 40 20 50 Max Units ns ns ns ns ns ns ns ns ns ns
PROPRIETARY AND CONFIDENTIAL
275
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Figure 42: Microprocessor Interface Read Timing tSAR A[13:0] tS ALR tVL ALE tSLR (CSB+RDB) tZ INTH INTB tHLR tHALR
Valid
Address
tH AR
tPRD D[7:0]
tZ RD
Valid Data
Notes on Microprocessor Interface Read Timing: 1. Output propagation delay time is the time in nanoseconds from the 1.4 Volt point of the reference signal to the 1.4 Volt point of the output. 2. Maximum output propagation delays are measured with a 100 pF load on the Microprocessor Interface data bus, (D[7:0]). 3. A valid read cycle is defined as a logical OR of the CSB and the RDB signals. 4. In non-multiplexed address/data bus architectures, ALE should be held high so parameters tSALR, tHALR, tVL, and tSLR are not applicable.
PROPRIETARY AND CONFIDENTIAL
276
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
5. Parameter tHAR is not applicable if address latching is used. 6. When a set-up time is specified between an input and a clock, the set-up time is the time in nanoseconds from the 1.4 Volt point of the input to the 1.4 Volt point of the clock. 7. When a hold time is specified between an input and a clock, the hold time is the time in nanoseconds from the 1.4 Volt point of the input to the 1.4 Volt point of the clock.
Table 46 Symbol tSAW tSDW tSALW tHALW tVL tSLW tHLW tHDW tHAW TVWR
- Microprocessor Interface Write Access Parameter Address to Valid Write Set-up Time Data to Valid Write Set-up Time Address to Latch Set-up Time Address to Latch Hold Time Valid Latch Pulse Width Latch to Write Set-up Latch to Write Hold Data to Valid Write Hold Time Address to Valid Write Hold Time Valid Write Pulse Width Min 10 20 10 10 20 0 5 5 5 40 Max Units ns ns ns ns ns ns ns ns ns ns
PROPRIETARY AND CONFIDENTIAL
277
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Figure 43
- Microprocessor Interface Write Timing
A[9:0] tS ALW tV L ALE tSAW (CSB+WRB)
Valid Address
tH ALW tS LW tHLW
tVWR
tH AW
tS DW D[7:0]
tH DW
Valid Data
Notes on Microprocessor Interface Write Timing: 1. A valid write cycle is defined as a logical OR of the CSB and the WRB signals. 2. In non-multiplexed address/data bus architectures, ALE should be held high so parameters tSALW, tHALW, tVL, tSLW and tHLW are not applicable. 3. Parameter tHAW is not applicable if address latching is used. 4. When a set-up time is specified between an input and a clock, the set-up time is the time in nanoseconds from the 1.4 Volt point of the input to the 1.4 Volt point of the clock. 5. When a hold time is specified between an input and a clock, the hold time is the time in nanoseconds from the 1.4 Volt point of the input to the 1.4 Volt point of the clock.
PROPRIETARY AND CONFIDENTIAL
278
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
17
TEMUX TIMING CHARACTERISTICS (TA = -40C to +85C VDD3.3 = 3.3V 10%, VDD2.5 = 2.5V 8%) Table 47 Symbol tVRSTB Figure 44 - RTSB Timing Description RSTB Pulse Width - RSTB Timing tV RSTB RSTB Min 100 Max Units ns
Table 48 Symbol fTICLK t0TICLK t1TICLK tSTFPI
- DS3 Transmit Interface Timing Description TICLK Frequency TICLK minimum pulse width low TICLK minimum pulse width high TFPI/TMFPI to TICLK Set-up Time (LOOPT=0) TFPI/TMFPI to RCLK Set-up Time (LOOPT=1) (See Note 1) TFPI/TMFPI to TICLK Hold Time (LOOPT=0) TFPI/TMFPI to RCLK Hold Time (LOOPT=1) (See Note 2) TDATI to TICLK Set-up Time (LOOPT = 0) TDATI to RCLK Set-up Time (LOOPT = 1) (See Note 1) 7.7 7.7 5 5 1 1 5 5 ns ns Min Max Units 52 MHz ns ns ns
tHTFPI
TSTDATI
PROPRIETARY AND CONFIDENTIAL
279
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
THTDATI
TDATI to TICLK Hold Time (LOOPT = 0) TDATI to RCLK Hold Time (LOOPT = 1) (See Note 2) TICLK High to TPFO Prop Delay (See Note 3 and 4) TDATI to TGAPCLK Set-up Time (See Notes 1 and 5) TDATI to TGAPCLK Hold Time (See Note 2 and 5) TICLK Edge to TCLK Edge Prop Delay (See Notes 3 and 4) TCLK Edge to TPOS/TDAT Prop Delay (See Notes 3 and 4) TCLK Edge to TNEG/TMFP Prop Delay (See Notes 3 and 4) TICLK High to TPOS/TDAT Prop Delay (See Notes 3 and 4) TICLK High to TNEG/TMFP Prop Delay (See Notes 3 and 4)
1 1 2 3 2 2 -1 -1 2 2 13 5 5 13 13 16
ns
TPTFPO TSTGAP THTGAP TPTCLK TPTPOS TPTNEG tPTPOS2 TPTNEG2
ns ns ns ns ns ns ns ns
Notes on DS3 Transmit Interface Timing: 1. When a set-up time is specified between an input and a clock, the set-up time is the time in nanoseconds from the 1.4 Volt point of the input to the 1.4 Volt point of the clock. 2. When a hold time is specified between an input and a clock, the hold time is the time in nanoseconds from the 1.4 Volt point of the clock to the 1.4 Volt point of the input. 3. Output propagation delay time is the time in nanoseconds from the 1.4 Volt point of the reference signal to the 1.4 Volt point of the output. 4. Maximum and minimum output propagation delays are measured with a 20 pF load on all the outputs. 5. Setup and hold times relative to TGAPCLK are measured with a 20 pF load on aTGAPCLK.
PROPRIETARY AND CONFIDENTIAL
280
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Figure 91
- DS3 Transmit Interface Timing
TICLK/RCLK tS TFPI TFPI/TMFPI tH TFPI
TICLK/RCLK tS TDATI TDATI tH TDATI
TICLK/RCLK tPTFPO TFPO/TMFPO
TGAPCLK tS TGAP TDATI tH TGAP
PROPRIETARY AND CONFIDENTIAL
281
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
TICLK=0, TRISE=0
TICLK=0, TRISE=1
TICLK=1, TRISE=X
TICLK
TICLK
TICLK
tPTCLK tPTCLK
TCLK TCLK TCLK
tP TPOS
TPOS/TDAT TPOS/TDAT
tP TPOS
TPOS/TDAT
tPTPOS2
tP TNEG
TNEG/TMFP TNEG/TMFP
tP TNEG
TNEG/TMFP
tPTNEG2
PROPRIETARY AND CONFIDENTIAL
282
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Table 49 Symbol fRCLK t0RCLK t1RCLK tSRPOS tHRPOS tSRNEG tHRNEG tPRDATO tPRFPO tPROVRHD tPRGAP
- DS3 Receive Interface Timing Description RCLK Frequency RCLK minimum pulse width low RCLK minimum pulse width high RPOS/RDAT Set-up Time (See Note 1) RPOS/RDAT Hold Time (See Note 2) RNEG/RLCV Set-Up Time (See Note 1) RNEG/RLCV Hold Time (See Note 2) RSCLK Edge to RDATO Prop Delay (See Notes 3 and 4) RSCLK Edge to RFPO/RMFPO Prop Delay (See Notes 3 and 4) RSCLK Edge to ROVRHD Prop Delay (See Notes 3 and 4) RGAPCLK Edge to RDATO[x] Prop Delay (See Notes 3 and 4) 7.7 7.7 4 1 4 1 2 2 2 3 12 12 12 11 Min Max Units 52 MHz ns ns ns ns ns ns ns ns ns ns
Notes on DS3 Transmit Interface Timing: 1. When a set-up time is specified between an input and a clock, the set-up time is the time in nanoseconds from the 1.4 Volt point of the input to the 1.4 Volt point of the clock. 2. When a hold time is specified between an input and a clock, the hold time is the time in nanoseconds from the 1.4 Volt point of the clock to the 1.4 Volt point of the input. 3. Output propagation delay time is the time in nanoseconds from the 1.4 Volt point of the reference signal to the 1.4 Volt point of the output. 4. Maximum and minimum output propagation delays are measured with a 50 pF load on all the outputs.
PROPRIETARY AND CONFIDENTIAL
283
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Figure 92
- DS3 Receive Interface Timing RCLK tS RPOS tH RPOS
RPOS/RDAT tS RNEG RNEG/RLCV tH RNEG
RSCLK tP RDATO RDATO tP RFPO RFPO/RMFPO tPROVRHD ROVRHD Dashed line RSCLK represents behaviour when RSCLKR register bit = 1.
PROPRIETARY AND CONFIDENTIAL
284
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
RGAPCLK tP RGAP RDATO Dashed line RSCLK represents behaviour when RSCLKR register bit = 1. Table 50 Symbol - Line Side Telecom BUS Input Timing (Figure 96) Description LREFCLK Frequency LREFCLK Duty Cycle CLK52M Frequency (51.84 MHz) CLK52M Frequency (44.928 MHz) CLK52M Duty Cycle tSTEL tHTEL All Telecom BUS Inputs Set-Up Time to LREFCLK (See Note 1) All Telecom BUS Inputs Hold Time to LREFCLK (See Note 2) Min 19.44 -20 ppm 40 51.84 -50 ppm 44.928 -50 ppm 40 5 1 Max 19.44 +20 ppm 60 51.84 +50 ppm 44.928 +50 ppm 60 Units MHz % MHz MHz % ns ns
Notes on Telecom Input Timing: 1. When a set-up time is specified between an input and a clock, the set-up time is the time in nanoseconds from the 1.4 Volt point of the input to the 1.4 Volt point of the clock. 2. When a hold time is specified between an input and a clock, the hold time is the time in nanoseconds from the 1.4 Volt point of the clock to the 1.4 Volt point of the input.
PROPRIETARY AND CONFIDENTIAL
285
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Figure 93
- Line Side Telecom BUS InputTiming
LREFCLK LAC1 LDDATA[7:0] LDDP,LDPL LDTPL,LDAIS LDV5,LDC1J1 tS TEL tH TEL
Table 51 Symbol tPTEL tZTEL tPTELOE
- Telecom BUS Output Timing (Figure 97 to Figure 98) Description LREFCLK to all Telecom BUS Outputs Valid (See Notes 1,2 and 4) LREFCLK to all Telecom BUS tristateable Outputs going tristate (See Note 3) LREFCLK to all Telecom BUS tristateable Outputs going valid from tristate (See Notes 1,2 and 4) Min 3 3 3 Max 20 12 20 Units ns ns ns
Notes on Telecom Bus Output Timing: 1. Output propagation delay time is the time in nanoseconds from the 1.4 Volt point of the reference signal to the 1.4 Volt point of the output. 2. Maximum and minimum output propagation delays are measured with a 100 pF load on all the outputs. 3. Output tristate delay is the time in nanoseconds from the 1.4 Volt point of the reference signal to the point where the total current delivered through the output is less than or equal to the leakage current. 4. The propagation delay, tPTEL, should be used when Telecom bus outputs are always driven as configured by LADDOE in register 1200H. The propagation delays, tPTELOE and tZTEL, should be used when the Telecom bus outputs are multiplexed with other TEMUX devices using the tristate capability of the
PROPRIETARY AND CONFIDENTIAL
286
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
outputs as configured by LADDOE in register 1200H. Note that consideration of each individual pin across the bus demonstrates that there are no reliability issues related to signal contention. Figure 94 - Telecom BUS Output Timing
LREFCLK tPTEL
LADATA[7:0] LADP, LAPL LAOE LAC1J1V1 Figure 95
- Telecom BUS Tristate Output Timing
LREFCLK tPTELOE LADATA[7:0] LADP, LAPL tZ TEL
PROPRIETARY AND CONFIDENTIAL
287
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Table 52 Symbol
- SBI ADD BUS Timing (Figure 96) Description SREFCLK Frequency (See Note 6) SREFCLK Duty Cycle Min 19.44 -50 ppm 40 4 0.75 2 2 20 20 Max 19.44 +50 ppm 60 Units MHz % ns ns ns ns
tSSBIADD tHSBIADD tPSBIADD tZSBIADD
All SBI ADD BUS Inputs Set-Up Time to SREFCLK (See Note 1) All SBI ADD BUS Inputs Hold Time to SREFCLK (See Note 2) SREFCLK to SAJUST_REQ Valid (See Notes 3 and 4) SREFCLK to SAJUST_REQ Tristate (See Note 5)
Notes on SBI Input Timing: 1. When a set-up time is specified between an input and a clock, the set-up time is the time in nanoseconds from the 1.4 Volt point of the input to the 1.4 Volt point of the clock. 2. When a hold time is specified between an input and a clock, the hold time is the time in nanoseconds from the 1.4 Volt point of the clock to the 1.4 Volt point of the input. 3. Output propagation delay time is the time in nanoseconds from the 1.4 Volt point of the reference signal to the 1.4 Volt point of the output. 4. Maximum and minimum output propagation delays are measured with a 100 pF load on all the outputs. 5. Output tristate delay is the time in nanoseconds from the 1.4 Volt point of the reference signal to the point where the total current delivered through the output is less than or equal to the leakage current. 6. Note that in Transparent VT mode this clock must be connected to LREFCLK. In this case, the more stringent specification of +/- 20ppm applies.
PROPRIETARY AND CONFIDENTIAL
288
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Figure 96
SREFCLK
- SBI ADD BUS Timing
SC1FP SADATA[7:0] SADP,SAPL SAV5
tSSBIADD
tHSBIADD
tPSBIADD tZSBIADD SAJUST_REQ
Table 53 Symbol tPSBIDROP tPSBIACT tZSBIDROP TPOUTEN tZOUTEN tSDET tHDET
- SBI DROP BUS Timing (Figure 97 to Figure 98) Description SREFCLK to SBI DROP BUS Outputs Valid (See Notes 1 and 2) SREFCLK to SBIACT Output Valid (See Notes 1 and 3) SREFCLK to All SBI DROP BUS Outputs Tristate (See Note 4) SBIDET[1] and SBIDET[0] low to All SBI DROP BUS Outputs Valid (See Notes 1 and 2) SBIDET[1] and SBIDET[0] high to All SBI DROP BUS Outputs Tristate (See Note 4) SBIDET[n] Set-Up Time to SREFCLK (See Notes 5) SBIDET[n] Hold Time to SREFCLK (See Notes 6) Min 2 2 2 2 Max 20 19 12 15 Units ns ns ns ns
2 4 0
12
ns ns ns
PROPRIETARY AND CONFIDENTIAL
289
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Notes on SBI Output Timing: 1. Output propagation delay time is the time in nanoseconds from the 1.4 Volt point of the reference signal to the 1.4 Volt point of the output. 2. Maximum and minimum output propagation delays are measured with a 100 pF load on all the outputs. 3. Maximum and minimum output propagation delay is measured with a 50pF load. 4. Output tristate delay is the time in nanoseconds from the 1.4 Volt point of the reference signal to the point where the total current delivered through the output is less than or equal to the leakage current. 5. When a set-up time is specified between an input and a clock, the set-up time is the time in nanoseconds from the 1.4 Volt point of the input to the 1.4 Volt point of the clock. 6. When a hold time is specified between an input and a clock, the hold time is the time in nanoseconds from the 1.4 Volt point of the clock to the 1.4 Volt point of the input.
PROPRIETARY AND CONFIDENTIAL
290
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Figure 97
- SBI DROP BUS Timing
SREFCLK tPSBIDROP SDDATA[7:0] SDDP, SDPL SDV5 tPSBIACT SBIACT tZSBIDROP SDDATA[7:0] SDDP, SDPL SDV5 Figure 98 - SBI DROP BUS Collision Avoidance Timing
SREFCLK tSDET SBIDET[n] tPOUTEN SDDATA[7:0] SDDP, SDPL SDV5 tZOUTEN tHDET
PROPRIETARY AND CONFIDENTIAL
291
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Table 54 Symbol
- H-MVIP Egress Timing (Figure 99) Description CMV8MCLK Frequency (See Note 3) CMV8MCLK Duty Cycle CMVFPC Frequency (See Note 4) CMVFPC Duty Cycle Min 16.368 40 4.092 40 -10 5 5 5 5 Max 16.400 60 4.100 60 10 Units MHz % MHz % ns ns ns ns ns
tPMVC TSHMVED tHHMVED TSMVFPB THMVFPB
CMV8MCLK to CMVFPC skew MVED[7:1], CASED[7:1], CCSED SetUp Time MVED[7:1], CASED[7:1], CCSED Hold Time CMVFPB Set-Up Time (See Note 1) CMVFPB Hold Time (See Note 2)
Notes on H-MVIP Egress Timing: 1. When a set-up time is specified between an input and a clock, the set-up time is the time in nanoseconds from the 1.4 Volt point of the input to the 1.4 Volt point of the clock. 2. When a hold time is specified between an input and a clock, the hold time is the time in nanoseconds from the 1.4 Volt point of the clock to the 1.4 Volt point of the input. 3. Measured between any two CMV8MCLK falling edges. 4. Measured between any two CMVFPC falling edges.
PROPRIETARY AND CONFIDENTIAL
292
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Figure 99
- H-MVIP Egress Data & Frame Pulse Timing
CMVFPC tSMVFPB CMVFPB tPMVC CMV8MCLK tSHMVED tHHMVED tHMVFPB
MVED[x] CASED[x] CCSED
Table 55 Symbol tPHMVID
- H-MVIP Ingress Timing (Figure 100) Description CMV8MCLK Low to MVID[7:1], CASID[7:1], CCSID Valid (See Notes 1 and 2) Min 5 Max 25 Units ns
Notes on H-MVIP Ingress Timing: 1. Output propagation delay time is the time in nanoseconds from the 1.4 Volt point of the reference signal to the 1.4 Volt point of the output. 2. Maximum and minimum output propagation delays are measured with a 50 pF load on all the outputs.
PROPRIETARY AND CONFIDENTIAL
293
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Figure 100 - H-MVIP Ingress Data Timing
CMV8MCLK tPHMVID MVID[x] CASID[x] CCSID
PROPRIETARY AND CONFIDENTIAL
294
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Table 56 Symbol tLXCLK tHXCLK tXCLK
- XCLK Input (Figure 101) Description XCLK Low Pulse Width4 XCLK High Pulse Width4 XCLK Period (typically 1/37.056 MHz 32 ppm for T1 operation or 1/49.152 MHz for E1 operation)5 Min 8 8 20 Max Units ns ns ns
Figure 101 - XCLK Input Timing
t H XCLK
XCLK
t L XCLK
t XCLK
PROPRIETARY AND CONFIDENTIAL
295
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Table 57 Symbol
- Egress Interface Timing - Clock Slave: EFP Enabled Mode (Figure 102) Description Common Egress Clock Frequency1,2(Typically 1.544 MHz 130 ppm or 2.048 MHz 130 ppm for T1 modes and 2.048 MHz 50ppm for E1 modes) Min 1.5 Max 2.1 Units MHz
t1CECLK t0CECLK t1CECLK t0CECLK tSCECLK tHCECLK tPEFP1
Common Egress High Pulse Width2,4 (XCLK = 37.056 MHz) Common Egress Low Pulse Width2,4 (XCLK = 37.056 MHz) Common Egress High Pulse Width2,4 (XCLK = 49.152 MHz) Common Egress Low Pulse Width2,4 (XCLK = 49.152 MHz) CECLK to Input Set-up Time7,9 CECLK to Input Hold Time8,9 CECLK to EFP[x] Propagation delay9,10,11
167 167 145 145 20 20 5 100
ns ns ns ns ns ns ns
PROPRIETARY AND CONFIDENTIAL
296
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Figure 102 - Egress Interface Timing - Clock Slave: EFP Enabled Mode
CEFP ED[x]
Valid tS CECLK tHCECLK
CECLK
t0 CECLK
t1 CECLK
EFP[x] tP EFP1
Valid
Table 58 Symbol
- Egress Interface Timing - Clock Slave: External Signaling (Figure 103) Description Common Egress Clock Frequency1,2(Typically 1.544 MHz 130 ppm or 2.048 MHz 130 ppm for T1 modes and 2.048 MHz 50ppm for E1 modes) Min 1.5 Max 2.1 Units MHz
t1CECLK t0CECLK t1CECLK t0CECLK tSCECLK tHCECLK
Common Egress High Pulse Width2,4 (XCLK = 37.056 MHz) Common Egress Low Pulse Width2,4 (XCLK = 37.056 MHz) Common Egress High Pulse Width2,4 (XCLK = 49.152 MHz) Common Egress Low Pulse Width2,4 (XCLK = 49.152 MHz) CECLK to Input Set-up Time7,9 CECLK to Input Hold Time8,9
167 167 145 145 20 20
ns ns ns ns ns ns
PROPRIETARY AND CONFIDENTIAL
297
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Figure 103 - Egress Interface Timing - Clock Slave: External Signaling Mode
CEFP ED[x] ESIG[x]
Valid tS CECLK tHCECLK t0 CECLK
CECLK
t1 CECLK
PROPRIETARY AND CONFIDENTIAL
298
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Table 59 Symbol tSECLK tHECLK
- Egress Interface Input Timing - Clock Master : NxChannel Mode (Figure 104) Description ECLK[x] to ED[x] Set-up Time7,9 ECLK[x] to ED[x] Hold Time8,9 Min 30 30 Max Units ns ns
Figure 104 - Egress Interface Input Timing - Clock Master : NxChannel Mode
ED[x]
Valid tS ECLK tHECLK
ECLK[x]
PROPRIETARY AND CONFIDENTIAL
299
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Table 60 Symbol tSECLK tHECLK
- Egress Interface Input Timing - Clock Master : Clear Channel Mode (Figure 104) Description ECLK[x] to ED[x] Set-up Time7,9 ECLK[x] to ED[x] Hold Time8,9 Min 30 30 Max Units ns ns
Figure 105 - Egress Interface Input Timing - Clock Master : Clear Channel Mode
ED[x]
Valid tS ECLK tHECLK
ECLK[x]
Note: ECLK[x] is an output derived from CECLK or CTCLK.
PROPRIETARY AND CONFIDENTIAL
300
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Table 61 Symbol tSICLK tHICLK
- Egress Interface Input Timing - Clock Master : Serial Data and HMVIP CCS Mode (Figure 104) Description ICLK[x] to ED[x] Set-up Time7,9 ICLK[x] to ED[x] Hold Time8,9 Min 30 30 Max Units ns ns
Figure 106 - Egress Interface Input Timing - Clock Master : Serial Data and HMVIP CCS Mode ED[x] Valid tS ICLK tHICLK ICLK[x]
Note: ICLK[x] is an output derived from CMV8MCLK.
PROPRIETARY AND CONFIDENTIAL
301
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Table 62 Symbol tSECLK tHECLK
- Egress Interface Input Timing - Clock Slave : Clear Channel Mode (Figure 104) Description ECLK[x] to ED[x] Set-up Time7,9 ECLK[x] to ED[x] Hold Time8,9 Min 30 30 Max Units ns ns
Figure 107 - Egress Interface Input Timing - Clock Slave : Clear Channel Mode ED[x] Valid tS ECLK tHECLK ECLK[x] Note: ECLK[x] is an input.
PROPRIETARY AND CONFIDENTIAL
302
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Table 63 Symbol
- Ingress Interface Timing - Clock Slave Modes (Figure 108) Description Common Ingress Clock Frequency1,2 (Typically 1.544 MHz 130 ppm or 2.048 MHz 130 ppm for T1 modes and 2.048 MHz 50ppm for E1 modes) Min 1.5 Max 2.1 Units MHz
t1CICLK t0CICLK t1CICLK t0CICLK tSCICLK tHCICLK tPCICLK
Common Ingress High Pulse Width2,4 (XCLK = 37.056 MHz) Common Ingress Low Pulse Width2,4 (XCLK = 37.056 MHz) Common Ingress High Pulse Width2,4 (XCLK = 49.152 MHz) Common Ingress Low Pulse Width2,4 (XCLK = 49.152 MHz) CICLK to CIFP Set-up Time7,9 CICLK to CIFP Hold Time8,9 CICLK to Ingress Output Prop. Delay9,10,11
167 167 145 145 20 20 5 100
ns ns ns ns ns ns ns
PROPRIETARY AND CONFIDENTIAL
303
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Figure 108 - Ingress Interface Timing - Clock Slave Modes CIFP Valid tS CICLK tHCICLK CICLK ID[x] ISIG[x] IFP[x] tP CICLK t0 CICLK t1 CICLK
Valid
PROPRIETARY AND CONFIDENTIAL
304
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Table 64 Symbol tPICLK
- Ingress Interface Timing - Clock Master Modes (Figure 109) Description ICLK[x] to Ingress Output Prop. Delay9,10,11 Min -20 Max 20 Units ns
Figure 109 - Ingress Interface Timing - Clock Master Modes ICLK[x]
ID[x] IFP[x] tP ICLK
Valid
PROPRIETARY AND CONFIDENTIAL
305
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Table 65 Symbol
- Transmit Line Interface Timing (Figure 110) Description Min Max 2.1 Units MHz
CTCLK Frequency (when used for TJAT 1.5 REF), typically 1.544 MHz 130 ppm for T1 operation or 2.048 MHz 50 ppm for E1 operation2,3,6 tHCTCLK tLCTCLK Figure 110 CTCLK High Duration4 (when used for TJAT REF) CTCLK Low Duration4 (when used for TJAT REF) - Transmit Line Interface Timing 100 100
ns ns
t HCTCLK
CTCLK
t L CTCLK
t CTCLK
Notes on Ingress and Egress Serial Interface Timing:
1. CECLK and CICLK can be gapped and/or jittered clock signals subject to the minimum high and low times shown. These specifications correspond to nominal XCLK input frequencies. 2. Guaranteed by design for nominal XCLK input frequency (37.056 MHz 100 ppm for T1 modes and 49.152 MHz 50ppm for E1 modes). 3. CTCLK can be a jittered clock signal subject to the minimum high and low times shown. These specifications correspond to nominal XCLK input frequency of 37.056 MHz 100 ppm for T1 modes and 49.152 MHz 50ppm for E1 modes. 4. High pulse width is measured from the 1.4 Volt points of the rise and fall ramps. Low pulse width is measured from the 1.4 Volt points of the fall and rise ramps.
PROPRIETARY AND CONFIDENTIAL
306
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
5. XCLK frequency must be 24x the line rate 32 ppm when TJAT is freerunning or referenced to a derivative of XCLK. XCLK may be 100 ppm if an accurate reference is provided to TJAT. 6. CTCLK can be a jittered clock signal subject to the minimum high and low durations tHCTCLK, tLCTCLK. These durations correspond to nominal XCLK input frequency. 7. When a set-up time is specified between an input and a clock, the set-up time is the time in nanoseconds from the 1.4 Volt point of the input to the 1.4 Volt point of the clock. 8. When a hold time is specified between an input and a clock, the hold time is the time in nanoseconds from the 1.4 Volt point of the clock to the 1.4 Volt point of the input. 9. Setup, hold, and propagation delay specifications are shown relative to the default active clock edge, but are equally valid when the opposite edge is selected as the active edge. 10. Output propagation delay time is the time in nanoseconds from the 1.4 Volt point of the reference signal to the 1.4 Volt point of the output. 11. Output propagation delays are measured with a 50 pF load on all outputs with the exception of the high speed DS3 outputs (TCLK, TPOS/TDAT, TNEG/TMFP). The TCLK, TPOS/TDAT, TNEG/TMFP output propagation delays are measured with a 20 pF load.
Table 66 Symbol - Remote Serial Alarm Port Timing Description Min Max Units
RADEASTCK and RADWESTCK Frequency RADEASTCK and RADWESTCK Duty Cycle tHRADFP tSRADFP tHRAD tSRAD RADEASTFP and RADWESTFP Hold Time RADEASTFP and RADWESTFP Setup Time RADEAST and RADWEST Hold Time RADEAST and RADWEST Setup Time
1.344 40 5 5 5 5
10 60
MHz % ns ns ns ns
PROPRIETARY AND CONFIDENTIAL
307
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Figure 111
- Remote Serial Alarm Port Timing
RADEASTCK/ RADWESTCK tSRADFP RADEASTFP/ RADWESTFP tSRAD RADEAST/ RADWEST tHRAD tHRADFP
PROPRIETARY AND CONFIDENTIAL
308
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Table 67 Symbol
- JTAG Port Interface Description Min Max Units
TCK Frequency TCK Duty Cycle tSTMS tHTMS tSTDI tHTDI tPTDO tVTRSTB TMS Set-up time to TCK TMS Hold time to TCK TDI Set-up time to TCK TDI Hold time to TCK TCK Low to TDO Valid TRSTB Pulse Width 40 50 100 50 100 2 100
1 60
MHz % ns ns ns ns
100
ns ns
PROPRIETARY AND CONFIDENTIAL
309
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
Figure 112
- JTAG Port Interface Timing
TCK tS TMS TMS tS TDI TDI tH TDI tH TMS
TCK tP TDO TDO
tV TRSTB TRSTB
PROPRIETARY AND CONFIDENTIAL
310
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
18
ORDERING AND THERMAL INFORMATION Table 68 Part No. - Ordering and Thermal Information Description
PM8315-PI
Table 69
324 Plastic Ball Grid Array (PBGA)
- Thermal information - Theta Ja vs. Airflow
Theta JA (C/W) @ specified power Dense Board
Convection
35.3
Forced Air (Linear Feet per Minute) 100 200 300 400 500
31.0 27.9 25.9 24.5 23.6
JEDEC Board
20.5
18.8
17.7
16.8
16.3
15.8
PROPRIETARY AND CONFIDENTIAL
311
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
19
MECHANICAL INFORMATION Figure 113 - 324 Pin PBGA 23x23mm Body
0 .2 0 (4X )
D D1
A1 BAL L PAD CORNER
A
0.30 M C A B 0.10 M C B
22 21 20 18 17 16 15 14 13 12 10 9 8 7 6 5 4 3 2 1 19 11
A1 BAL L CORNER
e
A1 BAL L INDICATOR
E1
E
45 C HAM F ER 4 PLA CES
J I
A B C D E F G H J K L M N P R T U V W Y AA AB
b "d" DIA. 3 PLA CES
TO P VIEW
C A
30 TYP
BO TT OM VIEW
bbb C
aaa C
C
A1
A2
SEATING PLA NE
SID E VIEW
NO TES: 1) ALL DIM EN SIO NS IN M ILLIM ET ER . 2) DIME NSIO N aaa DENO TE S C OP LANA RIT Y. 3) DIME NSIO N bbb DE NO TES PAR ALLEL.
1.82 2.03 2.22
2.07 2.28 2.49
0.40 0.50 0.60
1.12 1.17 1.22 23.00
19.00 19.50 20.20
0.30 0.36 0.40
0.55 0.61 0.67 23.00
19.00 19.50 20.20 1.00 1.00
0.50 0.63 0.70 1.00 1.00 0.15 0.35
PROPRIETARY AND CONFIDENTIAL
312
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
NOTES
PROPRIETARY AND CONFIDENTIAL
313
STANDARD PRODUCT DATASHEET PMC-1981125 ISSUE 7
PM8315 TEMUX
HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED VT/TU MAPPER AND M13 MUX
CONTACTING PMC-SIERRA, INC.
PMC-Sierra, Inc. 105-8555 Baxter Place Burnaby, BC Canada V5A 4V7 Tel: Fax: (604) 415-6000 (604) 415-6200 document@pmc-sierra.com info@pmc-sierra.com apps@pmc-sierra.com http://www.pmc-sierra.com
Document Information: Corporate Information: Application Information: Web Site:
None of the information contained in this document constitutes an express or implied warranty by PMC-Sierra, Inc. as to the sufficiency, fitness or suitability for a particular purpose of any such information or the fitness, or suitability for a particular purpose, merchantability, performance, compatibility with other parts or systems, of any of the products of PMC-Sierra, Inc., or any portion thereof, referred to in this document. PMC-Sierra, Inc. expressly disclaims all representations and warranties of any kind regarding the contents or use of the information, including, but not limited to, express and implied warranties of accuracy, completeness, merchantability, fitness for a particular use, or non-infringement. In no event will PMC-Sierra, Inc. be liable for any direct, indirect, special, incidental or consequential damages, including, but not limited to, lost profits, lost business or lost data resulting from any use of or reliance upon the information, whether or not PMC-Sierra, Inc. has been advised of the possibility of such damage. (c) 2001 PMC-Sierra, Inc. PMC-1981125 (R7) ref PMC-1971268 (R7) Issue date: May 2001
PMC-Sierra, Inc. .415.6000
105 - 8555 Baxter Place Burnaby, BC Canada V5A 4V7
604


▲Up To Search▲   

 
Price & Availability of PM8315

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X